JOHNSON JHT7161 Module

تعليمات الاستخدام
This section will contain detailed instructions on how to integrate and operate the JHT7161 module. Please refer to the full product documentation for comprehensive guidance.
General Integration Guidelines:
- Ensure proper connection of the UART_RX/TX for communication.
- Connect the JHT-NFC-ANT using the provided 35cm ANT Cable.
- Adhere to the specified operating temperature range of 0~70°C.
نِطَاق
This specification applies to JHT7161 module
العصارة: 1000522891
Types and specifications
Specifications of key parts
| Module : | ج.ه.ت.7161 | |
| Output, input control characteristic | PCB Size , material | 54mm*40mm*1.6mm(±10%)FR-4 |
| مدخل | 5VDC±5%/400mA(J1_3,4) | |
|
طرق الاتصال |
1.UART_RX/TX.
2. RFID(13.56MHZ). |
|
|
آخر |
درجة حرارة التشغيل
يتراوح |
0 درجة مئوية ~ 70 درجة مئوية |
| نطاق درجة حرارة التخزين | -40 درجة مئوية ~ 85 درجة مئوية | |
|
مظهر |
PCBA |
|
| هوائي | JHT-NFC-ANT (SAP No: 1000523038) | |
| Output, input
control characteristic |
PCB Size , material | 45mm*43mm*1.6mm(±10%)FR-4 |
| مدخل | NA | |
|
طرق الاتصال |
ANT Cable(35cm) |
|
|
آخر |
درجة حرارة التشغيل
يتراوح |
0 درجة مئوية ~ 70 درجة مئوية |
| نطاق درجة حرارة التخزين | -40 درجة مئوية ~ 85 درجة مئوية | |
|
مظهر |
PCBA |
![]() |
بيان التعرض للإشعاع الترددي الصادر عن لجنة الاتصالات الفيدرالية (FCC)
- لا يجوز وضع هذا الجهاز المرسل أو تشغيله بالاشتراك مع أي هوائي أو جهاز إرسال آخر.
- يتوافق هذا الجهاز مع حدود التعرض لإشعاع التردد اللاسلكي الصادرة عن لجنة الاتصالات الفيدرالية (FCC) المنصوص عليها في البيئة غير الخاضعة للرقابة. يجب تثبيت هذا الجهاز وتشغيله بمسافة لا تقل عن 20 سم بين الرادياتير وجسمك
تحذير: إن إجراء تغييرات أو تعديلات على هذه الوحدة دون موافقة صريحة من الطرف المسؤول عن الامتثال قد يؤدي إلى إلغاء سلطة المستخدم لتشغيل الجهاز.
- للامتثال لمتطلبات الامتثال الخاصة بالتعرض للترددات اللاسلكية الصادرة عن لجنة الاتصالات الفيدرالية (FCC) ، يجب الحفاظ على مسافة فاصلة لا تقل عن 20 سم بين هوائي هذا الجهاز وجميع الأشخاص.
- يجب ألا يتم وضع جهاز الإرسال هذا في موقع مشترك أو تشغيله جنبًا إلى جنب مع أي هوائي أو جهاز إرسال آخر
This device is intended only for OEM integrators under the following conditions: 1) The antenna must be installed such that 20 cm is maintained between the antenna and users. For laptop installations, the antenna must be installed to ensure that the proper spacing is maintained in the event the users places the device in their lap during use (i.e. positioning of antennas must be placed in the upper portion of the LCD panel only to ensure 20 cm will be maintained if the user places the device in their lap for use) and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as the 2 conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for examp(الانبعاثات من الأجهزة الرقمية، ومتطلبات الأجهزة الطرفية للكمبيوتر الشخصي، وما إلى ذلك).
ملحوظة هامة:
في حالة عدم إمكانية استيفاء هذه الشروط (على سبيل المثالample certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling This transmitter module is authorized only for use in devices where the antenna may be installed such that 20 cm may be maintained between the antenna and users (for example access points, routers, wireless ASDL modems, certain laptop configurations, and similar equipment). The final end product must be labeled in a visible area with the following: “Contains TX FCC ID: TN7JHT7161”. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
استكشاف الأخطاء وإصلاحها
This section will provide common troubleshooting steps for issues encountered with the JHT7161 module.
- Communication Issues (UART/RFID): Verify all connections are secure and correctly wired. Check power supply to the module.
- الوحدة لا تستجيب: Ensure the module is receiving adequate power and is within the specified operating temperature range.
- تدخل: If experiencing interference, ensure the module is not co-located with other transmitting devices. Maintain the recommended separation distance from other antennas.
تحذير: إن إجراء تغييرات أو تعديلات على هذه الوحدة دون موافقة صريحة من الطرف المسؤول عن الامتثال قد يؤدي إلى إلغاء سلطة المستخدم لتشغيل الجهاز.
الأسئلة الشائعة
- Q: What is the operating temperature range for the JHT7161 module?
A: The operating temperature range is 0~70°C. - Q: What communication methods does the JHT7161 module support?
A: It supports UART_RX/TX and RFID (13.56MHZ). - Q: What is the required separation distance for FCC RF exposure compliance?
A: A separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. - Q: Can I modify the JHT7161 module?
A: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void your authority to operate the equipment. - Q: What FCC ID should be on the final end product?
A: The final end product must be labeled in a visible area with the following: Contains TX FCC ID: TN7JHT7161.
المستندات / الموارد
![]() | JHT7161 Module |
مراجع
- دليل المستخدمmanual.tools