1. المقدمة
The Daytech DA10 Freezer and Refrigerator Door Alarm is designed to alert users when a refrigerator or freezer door has been left open for an extended period. This device helps prevent food spoilage and unnecessary energy consumption by providing timely audible notifications. It features adjustable delay settings, multiple alarm modes, and customizable volume levels to suit various environments and needs.
2. مواصفات المنتج
- Delayed Alert: Configurable delay times of 1, 2, 3, or 4 minutes before the alarm activates.
- Dual Ringing Modes: Choose between CHIME mode for a gentle reminder or ALARM mode for a loud alert.
- حجم قابل للتعديل: Five volume levels, ranging from 0 dB (silent) to 120 dB, allowing customization for different noise environments.
- تحذير انخفاض البطارية: The alarm provides a shorter beep duration when batteries are low, indicating it's time for replacement.
- الإغلاق التلقائي: If the door remains open, the alarm will stop after 30 minutes of continuous activation to conserve battery life.
- تطبيق متعدد الاستخدامات: Suitable for refrigerators, freezers, garage doors, shed doors, windows, cabinets, and other entry points.

الشكل 1: انتهىview of Daytech Freezer Door Alarm features.
3. محتويات العبوة
يرجى التحقق من الحزمة للتأكد من وجود جميع العناصر:
- Main Alarm Unit (1x)
- شريط مغناطيسي (1x)
- بطاريات AAA (2x)
- Double-sided Adhesive Tape (2x sets)
- براغي تركيب (2x)
- دليل المستخدم (1x)
الفيديو 1: فتح الصندوق وما بعدهview of the Daytech Freezer Door Alarm contents.
4. الإعداد والتثبيت
4.1 تركيب البطارية
- Open the battery compartment cover on the back of the main alarm unit.
- قم بإدخال بطاريتين AAA، مع التأكد من القطبية الصحيحة (+/-).
- أغلق غطاء حجرة البطارية جيدًا.
4.2 تركيب جهاز الإنذار
The alarm can be mounted using either the provided adhesive tape or screws.
- Clean the surface where the alarm will be installed to ensure it is dry and free of dust or grease.
- Attach the double-sided adhesive tape to the back of both the main alarm unit and the magnetic strip. Alternatively, use the provided screws for a more permanent installation.
- Position the main alarm unit on the door frame or the fixed part of the appliance.
- Position the magnetic strip on the moving part of the door, ensuring that the triangle marks on both the main unit and the magnetic strip are aligned.
- The distance between the main unit and the magnetic strip must be less than or equal to 0.98 inches (2.5 cm) عندما يكون الباب مغلقا.

Figure 2: Step-by-step installation guide for the alarm.

Figure 3: Installation and battery replacement visuals.
5. تعليمات التشغيل
5.1 تشغيل/إيقاف التشغيل واختيار الوضع
Use the 'CHIME/ALARM/OFF' switch on the side of the main unit to select the desired mode:
- رنين: The alarm will emit a chime sound when triggered.
- إنذار: The alarm will emit a loud siren sound when triggered.
- OFF: تم إيقاف تشغيل المنبه.
5.2 Setting Delay Time (1-4 Minutes)
Press the 'SET' key on the side of the main unit to cycle through the four delay modes. Each press will confirm the mode with a specific number of beeps:
- Mode 1 (1 beep): Alert after 1 minute, beeps every 15 seconds for 5 seconds until the door closes. (Recommended for refrigerators, basement doors).
- Mode 2 (2 beeps): Alert after 2 minutes, beeps every 10 seconds for 10 seconds until the door closes. (Recommended for garages, shed doors).
- Mode 3 (3 beeps): Alert after 3 minutes, beeps every 5 seconds for 15 seconds until the door closes. (Recommended for windows, cabinet doors).
- Mode 4 (4 beeps): Alert after 4 minutes, beeps every 20 seconds for 15 seconds until the door closes. (Recommended for offices, shop doors).

Figure 4: Four selectable delay modes and their alert patterns.
Video 2: Demonstration of setting the delay modes on the Daytech Freezer Door Alarm.
5.3 ضبط مستوى الصوت
Use the volume buttons (+/-) on the side of the main unit to adjust the alarm's loudness. There are 5 levels available, from 0 dB (silent) to 120 dB (maximum loudness).
Video 3: Guide to adjusting the volume levels of the Daytech Freezer Door Alarm.
6. الصيانة
6.1 التنظيف
Wipe the alarm unit and magnetic strip with a soft, dry cloth. Avoid using harsh chemicals or abrasive cleaners.
6.2 استبدال البطارية
When the low battery warning is activated (shorter beeps), replace the two AAA batteries promptly to ensure continuous operation. Follow the battery installation steps in Section 4.1.
7. استكشاف الأخطاء وإصلاحها
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| لا يصدر صوت الإنذار. | 1. البطاريات تالفة أو تم تركيبها بشكل غير صحيح. 2. Alarm is in 'OFF' mode. 3. Magnetic strip is too far from the main unit. | 1. Replace batteries and check polarity. 2. Switch to 'CHIME' or 'ALARM' mode. 3. Adjust placement to ensure distance is ≤ 0.98 inches (2.5 cm). |
| Alarm sounds too frequently. | Delay time is too short. | Increase the delay time using the 'SET' key (Mode 2, 3, or 4). |
| صوت المنبه منخفض جدًا/عالي جدًا. | Volume level is not set correctly. | Adjust the volume using the +/- buttons. |
| Low battery warning persists after replacement. | Incorrect battery type or faulty batteries. | Ensure new, alkaline AAA batteries are used. Try a different set of batteries. |
8. المواصفات
- نموذج: دا10
- أبعاد: 2.52 × 1.34 × 4.57 بوصة
- وزن السلعة: 3.98 أونصات
- مصدر الطاقة: بطاريات آا شينومكس x (وشملت)
- نوع خلية البطارية: قلوي
- طريقة التحكم: يلمس
- مستوى الضوضاء: 0-120 ديسيبل
- نوع التركيب: Wall Mount (Adhesive/Screws)
- الحد الأقصى لنطاق المستشعر: 0.98 بوصة (2.5 سم)
9. الضمان والدعم
Daytech products are designed for reliability and performance. For specific warranty information, please refer to the product packaging or contact Daytech customer support. If you encounter any issues or have questions regarding your Daytech DA10 Freezer and Refrigerator Door Alarm, please visit the official Daytech webالموقع أو اتصل بفريق خدمة العملاء لدينا للحصول على المساعدة.
معلومات الاتصال:
Please refer to the official Daytech webللحصول على أحدث معلومات الاتصال، يرجى زيارة الموقع الإلكتروني أو الاطلاع على عبوة المنتج.