1. المقدمة
This manual provides comprehensive instructions for the safe and effective use of the OWON SPE8105 Programmable DC Power Supply. It covers product features, component identification, setup procedures, operating instructions, maintenance guidelines, troubleshooting tips, and detailed technical specifications. Please read this manual thoroughly before operating the device to ensure proper functionality and safety.

Figure 1: OWON SPE8105 Lab Power Supply and included accessories (power cord, USB cable).
2. انتهى المنتجview
2.1 الميزات الرئيسية
- شاشة عرض متعددة المعلومات: A 2.8-inch TFT LCD simultaneously displays set and actual voltage, current, output power, cumulative runtime, and channel status. It automatically switches to Constant Current (CC) mode if the actual current exceeds the preset value.
- وظائف حماية متعددة: Includes current limit, thermal, voltage overload (OVP), short circuit, and overpower protection to enhance durability and longevity.
- تصميم منفذ USB مريح: Features a 5V/1A USB output port for charging mobile devices and a rear USB communication port for firmware updates and PC software control.
- Adjustable Power Supply: Constant power design with a wide application range, allowing flexible configuration of higher voltage and current within the rated power. Programmable with four groups of shortcut parameters and supports waveform editing and editable timing output for up to ten groups.
- صغير الحجم وخفيف الوزن: Measures 3.2 x 8.9 x 5.6 inches and weighs 3.3 pounds, optimizing workbench space and portability.
2.2 مكونات اللوحة الأمامية

Figure 2: Front and Rear Panel Layout of the OWON SPE8105.
- شاشة LCD مقاس 2.8 بوصة: Displays operational parameters and settings.
- Current Setting Button: Used to adjust current parameters.
- Overcurrent Protection Setting (OCP): Configures overcurrent protection limits.
- تعديل مقبض الباب: Rotary encoder for parameter adjustment.
- Channel Output On/Off Button: Activates or deactivates the output. Long press for automatic output function.
- Channel Output Terminals: Connect positive (red), negative (black), and ground (green) leads.
- Shortcut Output Button (Memory): Accesses stored parameters. Long press to enter the List waveform timing output interface.
- زر العرض: Toggles display modes or information.
- أوفرفولtage Protection Setting (OVP): Configures overvoltagحدود الحماية ه.
- المجلدtage Setting Button (V): Used to adjust voltagالمعلمات ه.
2.3 مكونات اللوحة الخلفية
- Intelligent Temperature Control Fan: Provides cooling for the unit.
- الصمامات: Overcurrent protection for the input power.
- مفتاح التشغيل: يقوم بتشغيل الوحدة أو إيقاف تشغيلها.
- USB Device Communication Port: For PC software control and firmware updates.
- Power Cord Socket: Connects the power supply to the AC mains.
3. الإعداد
- فك التعبئة: Carefully remove the power supply and all accessories from the packaging. Verify that all components listed in the package contents are present.
- الموقع: Place the power supply on a stable, level surface with adequate ventilation. Ensure that the fan vents on the rear panel are not obstructed.
- توصيل الطاقة: Connect the provided power cord to the power cord socket on the rear panel of the device, then plug the other end into a grounded AC power outlet (100-240V AC).
- اتصالات الإخراج: Connect your load to the output terminals on the front panel. Ensure correct polarity: red for positive (+), black for negative (-), and green for ground.
4. تعليمات التشغيل
4.1 تشغيل/إيقاف التشغيل
- To power on, press the power switch on the rear panel to the 'ON' position. The LCD will illuminate.
- To power off, press the power switch on the rear panel to the 'OFF' position.
4.2 حجم الإعدادtagهـ والحالية

الشكل 3: مفصل view of the 2.8-inch IPS LCD display.
- Press the 'V' button to select voltage adjustment. Rotate the adjustment knob to set the desired voltage.
- Press the 'I' button to select current adjustment. Rotate the adjustment knob to set the desired current limit.
- The display shows set values (Set) and actual output values.
4.3 Output Enable/Disable
- Press the 'On/Off' button to enable or disable the output to the connected load. The 'ON' or 'OFF' indicator on the display will change accordingly.
- A long press of the 'On/Off' button may activate an automatic output function, if configured.
4.4 Protection Functions (OVP/OCP)
- أوفرفولtagالحماية الإلكترونية (OVP): Press the 'OVP' button to set the maximum allowable output voltagه. إذا كان حجم الإخراجtage exceeds this limit, the power supply will shut down the output to protect the load.
- حماية التيار الزائد (OCP): Press the 'OCP' button to set the maximum allowable output current. If the output current exceeds this limit, the power supply will switch to CC mode or shut down the output.
4.5 وظيفة الذاكرة
- The 'Memory' button allows you to store and recall up to four groups of frequently used voltagه والإعدادات الحالية.
- A long press on the 'Memory' button will enter the List waveform timing output interface for advanced programming.
4.6 استخدام منفذ USB
- The front 5V/1A USB port can be used to charge compatible mobile devices.
- The rear USB communication port allows connection to a PC for software control and firmware updates. Refer to the OWON website for compatible software and update procedures.
5. الصيانة
- تنظيف: Disconnect the power supply from the AC mains before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- تهوية: Ensure that the ventilation openings are kept clear of dust and debris to prevent overheating.
- استبدال الصمامات: If the fuse blows, disconnect the power cord and replace it with a fuse of the same type and rating (refer to specifications).
- تخزين: عند عدم استخدام مصدر الطاقة لفترات طويلة، قم بتخزينه في بيئة جافة وخالية من الغبار.
6. استكشاف الأخطاء وإصلاحها
- لا يوجد طاقة: Check the power cord connection and ensure the power switch is in the 'ON' position. Verify the AC outlet is functional and check the fuse on the rear panel.
- لا إخراج: Ensure the output is enabled using the 'On/Off' button. Check for active OVP or OCP conditions that might have shut down the output. Verify connections to the load.
- مخرجات غير صحيحة: تحقق المجلدtage and current settings. Ensure the load is connected correctly and is within the power supply's operating range.
- ارتفاع درجة الحرارة: Ensure adequate ventilation around the unit. Clear any obstructions from the fan vents. Reduce the load if operating continuously at high power.
- For persistent issues, refer to the detailed troubleshooting guide on the OWON support webالموقع أو الاتصال بخدمة العملاء.
7. المواصفات

Figure 4: OWON SPE8105 Product Specifications.
| المعلمة | قيمة |
|---|---|
| نموذج | SPE8105 (OWON-SPS3081) |
| حجم الإخراجtage | 0-80 فولت |
| تيار الخرج | 0-10 أمبير |
| الحد الأقصى لقوة الإخراج | 500 واط |
| أوفرفولtagالحماية الإلكترونية (OVP) | 85 فولت |
| حماية التيار الزائد (OCP) | 11 أمبير |
| حماية من درجة الحرارة الزائدة (OTP) | 85 درجة مئوية |
| تنظيم الحمل (الحجم)tage) | ≤ 20mV |
| تنظيم الحمل (التيار) | ≤10 مللي أمبير |
| Power Regulation (Voltage) | ≤ 20mV |
| Power Regulation (Current) | ≤10 مللي أمبير |
| ضبط الدقة (مستوى الصوت)tage) | 10mV |
| ضبط الدقة (الحالية) | 1 مللي أمبير |
| دقة القراءة (المجلد)tage) | 10mV |
| دقة القراءة (الحالية) | 1 مللي أمبير |
| Setting Accuracy (25°C±5°C) (Voltage) | ≤0.01٪ ± 20mV |
| Setting Accuracy (25°C±5°C) (Current) | ≤0.05٪ ± 10mA |
| Readback Accuracy (25°C±5°C) (Voltage) | ≤0.01٪ ± 20mV |
| Readback Accuracy (25°C±5°C) (Current) | ≤0.05٪ ± 10mA |
| تموج وضجيج (مجلد)tage) | ≤50mVp-p |
| تموج وضوضاء (حالي) | ≤15mAp-p |
| Output Temperature Coefficient (Voltage) | 100 جزء في المليون/درجة مئوية |
| Output Temperature Coefficient (Current) | 200 جزء في المليون/درجة مئوية |
| Response Time (50%-100% rated load) | ≤5.0 مللي ثانية |
| تخزين | 4 مجموعة من البيانات |
| عرض | 2.8inch LCD (IPS) |
| الواجهة | جهاز USB |
| الأبعاد (العرض × الارتفاع × العمق) | 82 مم × 142 مم × 226 مم |
| وزن | حوالي 1.8 كجم |
Note: The instrument must be operated continuously for more than 30 minutes at the specified operating temperature to achieve the following specifications. Ripple & Noise bandwidth 20MHz, ripple bandwidth 1MHz, connect 10uF electrolytic capacitor in parallel with 0.1uF ceramic capacitor to the output terminal for testing.

Figure 5: OWON SPE8105 dimensions and internal component layout.
8. الضمان والدعم
OWON products are designed for reliability and performance. For warranty information, technical support, or service, please contact your local distributor or visit the official OWON webالموقع. احتفظ بإيصال الشراء الخاص بك كإثبات للشراء في حالة مطالبات الضمان.
Manufacturer: ZHANGZHOU LILLIPUT ELECTRONIC TECHNOLOGY CO.,LTD.