This manual provides essential instructions for the safe and efficient use of your Pulsar PGiPAIRB4 Inverter Generator Parallel Kit. This kit allows you to connect two compatible Pulsar inverter generators to double their power output, providing increased electrical capacity for various applications, including RV use.

Compatible Pulsar Generator Models: PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO.

معلومات السلامة

Always read and understand all safety warnings and instructions in this manual and the manuals of your connected generators before operation. Failure to follow these instructions can result in serious injury or property damage.

  • Ensure all connections are secure before starting generators.
  • Operate generators in a well-ventilated area to prevent carbon monoxide poisoning.
  • لا تعمل في ظروف رطبة.
  • Keep children and pets away from operating equipment.
  • Always turn off generators and disconnect spark plug wires before performing any maintenance or making connections.

محتويات الحزمة

تأكد من وجود جميع العناصر في الحزمة الخاصة بك:

  • Pulsar PGiPAIRB4 Parallel Kit Unit
  • Connection Cables (integrated)
  • دليل المستخدم (هذا المستند)
Pulsar PGiPAIRB4 Parallel Kit unit with cables

Image: The Pulsar PGiPAIRB4 Parallel Kit unit, showing the main box with receptacles and circuit breakers, and the integrated connection cables extending from it.

الإعداد والاتصال

Follow these steps to connect your parallel kit to two compatible Pulsar inverter generators:

  1. تحضير: Ensure both generators are turned off, cooled down, and disconnected from any loads. Place the generators on a level, stable surface in a well-ventilated area.
  2. Connect Parallel Cables: Locate the parallel connection ports on each generator. These are typically color-coded (red and black) and may have specific shapes.
    Close-up of parallel connection cables

    الصورة: لقطة مقربة view of the parallel kit's connection cables, showing the red and black connectors designed to plug into the generators.

    Connect the red cable from the parallel kit to the red parallel port on the first generator. Connect the black cable from the parallel kit to the black parallel port on the first generator. Repeat this process for the second generator.
    Close-up of parallel connection adapters

    Image: Various parallel connection adapters and plugs, illustrating the types of connections used for linking generators.

  3. اتصالات آمنة: Ensure all connections are firmly seated and secure. Loose connections can cause arcing or power interruptions.
  4. الترتيب النهائي: Position the parallel kit unit in a safe, accessible location, away from exhaust fumes and moisture.
    Two Pulsar generators connected with the parallel kit

    Image: Two Pulsar inverter generators shown from the rear, with the PGiPAIRB4 Parallel Kit connected to their respective parallel ports, demonstrating a complete setup.

تعليمات التشغيل

Once the parallel kit is securely connected to both generators:

  1. Start Generators: Start both inverter generators according to their individual operating instructions. Allow them to run for a few moments to stabilize.
  2. توصيل الأحمال: Plug your electrical loads into the receptacles on the PGiPAIRB4 Parallel Kit.
    • The L14-50 receptacle provides 120/240V output at 50 amps.
    • The L14-30 receptacle provides 120/240V output at 30 amps.
  3. شاشة: Observe the generator and parallel kit for proper operation. The circuit breakers on the parallel kit will trip if an overload occurs.
  4. اغلق: To shut down, first disconnect all loads from the parallel kit. Then, turn off both generators according to their individual instructions. Finally, disconnect the parallel kit cables.

صيانة

The Pulsar PGiPAIRB4 Parallel Kit requires minimal maintenance. Follow these guidelines:

  • Keep the unit clean and free of dirt, dust, and moisture.
  • Inspect cables and connectors regularly for any signs of wear, damage, or corrosion. Replace if necessary.
  • Store the kit in a dry, protected area when not in use.

استكشاف الأخطاء وإصلاحها

مشكلةالسبب المحتملحل
No power output from parallel kit.
  • Generators not started.
  • وصلات فضفاضة.
  • تعثر قاطع الدائرة.
  • Incompatible generators.
  • Ensure both generators are running.
  • Check all parallel cable connections.
  • Reset the circuit breaker on the parallel kit.
  • Verify generators are listed as compatible models.
قواطع الدائرة تتعطل بشكل متكرر.
  • حالة الزائد.
  • جهاز معيب.
  • قلل الحمل الكهربائي الإجمالي.
  • Test appliances individually to identify faulty ones.

تحديد

  • نموذج: PGiPAIRB4
  • حجم الإخراجtage: 120/240 فولت
  • تردد الإخراج: 60 هرتز
  • L14-50 Receptacle: 50 Amps
  • L14-30 Receptacle: 30 Amps
  • المولدات المتوافقة: Pulsar PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO
  • أبعاد المنتج: 12 × 9 × 4 بوصة
  • وزن السلعة: 3 رطل
  • الشركة المصنعة: النجم النابض

معلومات الضمان

For detailed warranty information regarding your Pulsar PGiPAIRB4 Parallel Kit, please refer to the warranty card included with your purchase or visit the official Pulsar Products webالموقع. احتفظ بإثبات الشراء الخاص بك لتقديم مطالبات الضمان.

دعم العملاء

If you have any questions, require technical assistance, or need to order replacement parts, please contact Pulsar Customer Support:

  • Webموقع: www.pulsarproducts.com
  • Refer to your product registration or warranty documentation for specific contact numbers or email addresses.

المستندات ذات الصلة - PGiPAIRB4

قبلview دليل تشغيل مولد الطاقة العاكس ثنائي الوقود من بولسار بقدرة 9500 واط
يوفر دليل التشغيل هذا تعليمات شاملة لمولد العاكس ثنائي الوقود Pulsar PGD95BiSCO بقدرة 9500 وات، ويغطي احتياطات السلامة والتشغيل والصيانة واستكشاف الأخطاء وإصلاحها.
قبلview دليل تشغيل مولد البنزين العاكس Pulsar PG2200BiS
دليل تشغيل شامل لمولد البنزين العاكس المحمول Pulsar PG2200BiS، يغطي السلامة والتشغيل والصيانة واستكشاف الأخطاء وإصلاحها لضمان الأداء الموثوق.
قبلview دليل تشغيل مولد العاكس المحمول Pulsar PG2000iS/PG2300iS
يُقدّم دليل التشغيل هذا معلومات أساسية للتشغيل الآمن، والتجميع، والصيانة، واستكشاف الأعطال وإصلاحها لمولدات البنزين المحمولة العاكسة من طراز Pulsar PG2000iS وPG2300iS. تعرّف على كيفية استخدام مولدك بكفاءة وأمان.
قبلview Pulsar 1600 Watt Inverter Generator Operator's Manual PGD16iSCO
Comprehensive operator's manual for the Pulsar PGD16iSCO 1600 Watt Inverter Generator. Includes detailed safety instructions, operating procedures, maintenance schedules, troubleshooting guides, and technical specifications for safe and efficient use.
قبلview دليل تشغيل مولد البنزين العاكس Pulsar PG2300iSCO
دليل تشغيل شامل لمولد البنزين العاكس Pulsar PG2300iSCO. يغطي هذا الدليل معلومات أساسية تشمل قواعد السلامة، وميزات المنتج، وتعليمات التجميع، وإجراءات التشغيل التفصيلية، وجداول الصيانة، ونصائح استكشاف الأعطال وإصلاحها، ومخطط الأسلاك لضمان الاستخدام الآمن والفعال للمولد.
قبلview دليل تشغيل مولد العاكس Pulsar PG4500BiSRCO
دليل التشغيل لمولد العاكس Pulsar PG4500BiSRCO، يغطي السلامة والميزات والتشغيل والصيانة واستكشاف الأخطاء وإصلاحها لاستخدام البنزين والغاز البترولي المسال بالوقود المزدوج.