GENMAX GM-PUMP

GENMAX 12V DC Electric Fuel Pump GMEFP Instruction Manual

Model: GM-PUMP

1. المقدمة

The GENMAX GMEFP is a 12V DC electric fuel pump designed to automatically transfer gasoline from an external fuel tank to your GENMAX small inverter generator. This system ensures continuous operation of your generator without manual refueling, enhancing convenience and efficiency.

This manual provides essential information for the safe and effective installation, operation, and maintenance of your GENMAX GMEFP fuel pump. Please read it thoroughly before use and retain it for future reference.

GENMAX GMEFP Electric Fuel Pump
Image 1.1: The GENMAX GMEFP 12V DC Electric Fuel Pump, designed for automatic fuel transfer.

2. معلومات السلامة

WARNING: Gasoline is highly flammable and its vapors are explosive. Always handle fuel with extreme caution.

3. مواصفات المنتج

4. محتويات العبوة

تأكد من تضمين جميع العناصر المدرجة أدناه في الحزمة الخاصة بك:

GENMAX GMEFP Fuel Pump and Accessories
Image 4.1: The GENMAX GMEFP fuel pump shown with its included accessories: 12V DC power plugs (crocodile clips and cigarette lighter type) and a fuel hose with a primer bulb. These components facilitate connection to various power sources and external fuel tanks.

5. الإعداد والتثبيت

Proper installation is crucial for the safe and efficient operation of the fuel pump. Follow these steps carefully:

5.1 فحص التثبيت المسبق

GENMAX GMEFP Fuel Pump Dimensions and Thread Size
Image 5.1: Detailed dimensions of the GENMAX GMEFP fuel pump, including thread size (1.95 inches diameter, 0.18 inches pitch) and overall height (7.3 inches), crucial for compatibility with external fuel tanks.

5.2 Connecting the Fuel Pump

  1. Install the Fuel Pump: Securely screw the GENMAX GMEFP fuel pump into the fuel tank opening of your generator. Ensure a tight seal to prevent leaks.
  2. Connect Fuel Hose to External Tank: Connect one end of the provided fuel hose (with the primer bulb) to the outflow port of your external fuel tank. Ensure this connection is secure.
  3. Connect Fuel Hose to Pump: Connect the other end of the fuel hose to the tubing connection port on the GENMAX GMEFP fuel pump. This port indicates fuel flow to the generator.
  4. توصيل الطاقة: Choose the appropriate 12V DC power plug (crocodile clips or cigarette lighter) and connect it to the 12V DC power cable of the fuel pump. Then, connect the power plug to your generator's 12V DC output or another suitable 12V DC power source.
  5. التمركز: Place the external fuel tank on a stable surface, ensuring it is below the generator's fuel tank for optimal gravity feed assistance during priming. Ensure the fuel hose is not kinked and is clear of hot engine components, especially the muffler.
GENMAX GMEFP Fuel Pump Connection Diagram
Image 5.2: Diagram illustrating the connection of the GENMAX GMEFP fuel pump to a generator and an external fuel tank. It shows the 12V DC power cable connection and the fuel hose routing, emphasizing to keep the hose away from the muffler.
GENMAX GMEFP Fuel Pump in operation with generator
Image 5.3: The GENMAX GMEFP fuel pump installed on a GENMAX generator, connected to an external red fuel tank. This setup demonstrates the automatic fuel replenishment system in use.

6. تعليمات التشغيل

Once the fuel pump is correctly installed and connected, follow these steps for operation:

  1. تجهيز نظام الوقود: Before starting the generator, use the primer bulb on the fuel hose to manually draw gasoline from the external tank towards the pump. Squeeze the bulb until it feels firm, indicating fuel has reached the pump.
  2. بدء المولد: Start your GENMAX inverter generator according to its own instruction manual.
  3. Activate the Fuel Pump: Locate the switch on the GENMAX GMEFP fuel pump and turn it to the "ON" position. The pump will begin to monitor the fuel level in the generator's tank.
  4. التزود بالوقود تلقائياً: When the generator's fuel level drops to a predetermined low point, the GMEFP pump will automatically activate and transfer fuel from the external tank to the generator's tank.
  5. Overfill Protection: The pump's internal fault detection system will automatically stop the fuel transfer once the generator's tank is full, preventing overfilling and ensuring safe operation.
  6. التشغيل المستمر: The pump will cycle on and off as needed to maintain the fuel level, allowing for extended, unattended generator operation.

ملحوظة: If the generator is not a GENMAX model, ensure its fuel tank depth and fuel cap thread are compatible with the pump before use.

7. الصيانة

Regular maintenance ensures the longevity and reliable performance of your GENMAX GMEFP fuel pump.

8. استكشاف الأخطاء وإصلاحها

If you encounter issues with your GENMAX GMEFP fuel pump, refer to the following common troubleshooting steps:

If these steps do not resolve the issue, please contact GENMAX customer support for assistance.

9. المواصفات

مواصفةالتفاصيل
نموذجGM-PUMP
ماركةجين ماكس
مصدر الطاقة12 فولت تيار مستمر
وضع التشغيلاوتوماتيكي
نوع الغازالغازولين
مادة الجسمبلاستيك
وزن العنصر3.65 جنيه (1.66 كيلوجرام)
نوع التركيبحامل الخزان
Applicable Generator Power2kW to 5kW (GENMAX inverter generators)
Compatible External Tank Capacity5-17 Gallons (tank not included)
Required Tank Port Depth> 3.74 بوصات
Required Tank Port Diameter2.17 بوصة
Required Tank Port Thread Pitch~ 0.18 inches

10. الضمان والدعم

The GENMAX GMEFP fuel pump comes with a ضمان لمدة 1 سنوات من تاريخ الشراء.

GENMAX also provides دعم فني مجاني مدى الحياة from experienced experts. If you have any questions, require assistance with installation, operation, or troubleshooting, please do not hesitate to contact GENMAX customer support.

For warranty claims or technical support, please refer to the contact information provided on the GENMAX official webالموقع أو مواد تسجيل المنتج الخاصة بك.

المستندات ذات الصلة - GM-PUMP

قبلview دليل مستخدم مولد العاكس ثلاثي الوقود Genmax GM17000iETC
دليل مستخدم شامل لمولد الطاقة العاكس ثلاثي الوقود Genmax GM17000iETC، يشمل التشغيل والسلامة والصيانة واستكشاف الأخطاء وإصلاحها والمواصفات الفنية. تعرّف على كيفية تشغيل وصيانة مولدك بأمان باستخدام البنزين وغاز البترول المسال والغاز الطبيعي.
قبلview دليل مستخدم مولد العاكس ثلاثي الوقود GENMAX GM17000iETC
دليل مستخدم شامل لمولد GENMAX GM17000iETC ثلاثي الوقود العاكس، يغطي جوانب السلامة والتشغيل والصيانة واستكشاف الأعطال والمواصفات الفنية. تعرّف على كيفية تشغيل وصيانة مولدك بأمان للبنزين وغاز البترول المسال والغاز الطبيعي.
قبلview دليل مستخدم مولد الطاقة المحمول GENMAX GM12000E/GM12000ED
دليل مستخدم شامل لمولدات البنزين المحمولة GENMAX GM12000E وGM12000ED، يغطي التشغيل والسلامة والصيانة واستكشاف الأعطال والمواصفات الفنية. يتضمن إمكانية استخدام نوعين من الوقود في طراز GM12000ED.
قبلview دليل مستخدم مولد العاكس Genmax GM7250iEDC
دليل مستخدم شامل لمولد الطاقة المحمول ثنائي الوقود Genmax GM7250iEDC. يغطي الدليل احتياطات السلامة، وتعليمات التشغيل، وجداول الصيانة، واستكشاف الأعطال وإصلاحها، والمواصفات الفنية لكل من استخدام البنزين وغاز البترول المسال.
قبلview دليل مستخدم مولد الطاقة المحمول ثلاثي الوقود Genmax GM15000ET
دليل مستخدم شامل لمولد Genmax GM15000ET ثلاثي الوقود المحمول، يغطي السلامة والتشغيل والتجميع والصيانة والمواصفات الفنية للبنزين وغاز البترول المسال والغاز الطبيعي.
قبلview دليل مستخدم مولد العاكس GENMAX GM7500iAED: السلامة والتشغيل والصيانة
دليل المستخدم الرسمي لمولد الطاقة المحمول ثنائي الوقود GENMAX GM7500iAED. يشمل الدليل الإعداد والتشغيل واحتياطات السلامة وجدول الصيانة واستكشاف الأعطال وإصلاحها والمواصفات الفنية واختيار المولد المناسب. ويتضمن تفاصيل حول استخدام البنزين وغاز البترول المسال.