1. المقدمة

The UNI-T UT205E is a 2nd generation 1000A True RMS Digital Clamp Meter designed for accurate and reliable electrical measurements. This device is suitable for a wide range of applications in industrial, commercial, and residential settings. It features a large LCD for high-definition display, auto backlight for easy reading in dark environments, and industrial-grade rubber buttons for durability. The UT205E is certified with CE, UKCA, and cETLus standards, ensuring compliance with safety and quality regulations.

2. معلومات السلامة

Always read and understand all safety warnings and operating instructions before using this instrument. Failure to observe safety precautions may result in electric shock, fire, or damage to the meter.

  • Ensure the meter is in good working condition and free from damage before each use.
  • لا تطبق المجلدtagأو التيار الذي يتجاوز الحدود القصوى المحددة للعداد.
  • استخدم دائمًا الوظيفة والنطاق الصحيحين للقياسات.
  • توخ الحذر عند العمل مع الفولtagيجب ألا تتجاوز البطاريات 30 فولت تيار متردد جذر متوسط ​​التربيع، أو 42 فولت ذروة، أو 60 فولت تيار مستمر، لأنها تشكل خطر صدمة كهربائية.
  • The UT205E conforms to CAT III 1000V and CAT IV 600V safety standards. Adhere to these category ratings for safe operation.
  • Wear appropriate personal protective equipment (PPE), such as insulated gloves and safety glasses, when performing electrical measurements.
  • Do not operate the meter in explosive gas, vapor, or dusty environments.
  • Overload protection is provided up to 1000V AC across all ranges to prevent damage to the meter from accidental wrong gear selection.

3. انتهى المنتجview

The UNI-T UT205E Digital Clamp Meter is designed for ease of use and durability. Below is an overview من مكوناتها وميزاتها الرئيسية.

3.1. المكونات

Diagram illustrating key components and functions of the UNI-T UT205E Digital Clamp متر

Figure 1: Key Components of the UT205E Digital Clamp Meter. This diagram highlights the clamp head, NCV sensing end, flashlight, function dial, LCD display, and function buttons.

  • Clamp فك: Used for non-contact AC/DC current measurement. Opens up to 42 mm to accommodate multiple conductors.
  • مشغل: يفتح ويغلق النافذةamp فك.
  • مفتاح دوار: Selects the desired measurement function (e.g., ACV, DCV, ACA, DCA, Resistance, Capacitance, Frequency, Temperature, Diode, Continuity).
  • شاشة عرض LCD: Large, high-definition display with auto backlight for clear readings in various lighting conditions.
  • الأزرار الوظيفية: Include SELECT, RANGE, REL/ZERO, Hz/INRUSH, HOLD, MAX/MIN, and LPF for advanced functions and settings.
  • زر المصباح: Activates the built-in flashlight for illuminating dark work areas.
  • NCV Sensing End: لعدم الاتصال المجلدtagالكشف الإلكتروني.

3.2. الميزات الرئيسية

  • RMS الحقيقي: يوفر قياسات دقيقة للأشكال الموجية غير الجيبية.
  • الإضاءة الخلفية التلقائية: Automatically illuminates the display for improved visibility.
  • وظيفة NCV: حجم عدم الاتصالtage detection with multi-segment display and audio/visual alarm.
  • Inrush Current Capturing: Measures the initial surge current of motors and other inductive loads.
  • Large Jaws: Jaws open up to 42 mm, allowing for measurements of multiple conductors.
  • Industrial-Grade Rubber Buttons: Ensures durability and tactile feedback.
  • مرشح الترددات المنخفضة (LPF): Enables stable and accurate voltage and frequency measurements in variable frequency drive (VFD) environments.
  • Optional Flexible Current Probe: Extends AC current measurement range up to 3000A for tight spaces (probe sold separately).

3.3. انتهى المنتجview فيديو

الفيديو 1: يوفر هذا الفيديو شرحًا شاملاًview of the UNI-T UT200 series clamp meters, including the UT205E. It demonstrates key features such as True RMS, auto backlight, NCV function, large jaws, and various measurement capabilities.

4. المواصفات

Below are the detailed technical specifications for the UNI-T UT205E Digital Clamp متر.

المعلمةقيمة
التيار المتردد (A)1000 أمبير
التيار المستمر (أمبير)1000 أمبير
المجلد ACtagه (الخامس)1000 فولت
المجلد العاصمةtagه (الخامس)1000 فولت
المقاومة (Ω)60 ميغا أوم
السعة (ف)60 ميل بحري
Temperature (C/F)-40 درجة مئوية ~ 1000 درجة مئوية / -40 درجة فهرنهايت ~ 1832 درجة فهرنهايت
التردد (هرتز)10 هرتز ~ 1 ميجا هرتز
دورة العمل (٪)10% ~ 90%
عرض العد6000
فتح الفك42 ملم
تصنيفات الفئةCAT III 1000 فولت، CAT IV 600 فولت
أبعاد المنتج6.5 × 4.33 × 4.72 بوصة
وزن العنصر1.32 رطل (0.6 كيلوغرام)
مصدر الطاقةتعمل بالبطارية (بطارية ليثيوم معدنية واحدة متضمنة)
Detailed technical specifications table for UNI-T UT200 series clamp أمتار

Figure 2: Detailed technical specifications for the UNI-T UT200 series, including the UT205E.

5. الإعداد

5.1. تركيب البطارية

The UT205E requires 1 Lithium Metal battery (included). To install or replace the battery:

  1. Ensure the meter is turned OFF and disconnect all test leads from the meter and the circuit under test.
  2. حدد موقع غطاء حجرة البطارية على الجزء الخلفي من العداد.
  3. استخدم مفك البراغي لفك البراغي التي تثبت غطاء البطارية.
  4. Remove the cover and insert the battery, observing the correct polarity (+/-) as indicated inside the compartment.
  5. أعد تركيب غطاء البطارية وقم بربط المسمار (المسامير) بإحكام.

5.2. توصيل أسلاك الاختبار

للمجلدtage, resistance, capacitance, frequency, diode, and continuity measurements, connect the test leads as follows:

  • Insert the red test lead into the VΩHz% input jack.
  • أدخل سلك الاختبار الأسود في مقبس إدخال COM.
UNI-T UT207B clamp meter with test leads, carrying case, and manual

Figure 3: The UT205E (similar to UT207B shown) with included test leads and carrying case.

6. أوضاع التشغيل

The UT205E offers various measurement functions. Use the rotary switch to select the desired mode.

6.1. قياس التيار المتردد/المستمر

To measure AC or DC current:

  1. Turn the rotary switch to the ACA (AC Current) or DCA (DC Current) position.
  2. اضغط على الزناد لفتح clamp فك.
  3. قم بتغليف موصل واحد بالعلبةamp jaw. Ensure the jaw is completely closed.
  4. Read the current value on the LCD display. For DC current, observe the polarity.

For measurements in tight spaces, an optional flexible current probe can be used (refer to Video 1, segment 02:02 for demonstration).

6.2. AC / DC Voltagهـ القياس

لقياس التيار المتردد أو العاصمة المجلدtage:

  1. Turn the rotary switch to the ACV (AC Voltage) or DCV (DC Voltagه) الموقف.
  2. Connect the red test lead to the live terminal and the black test lead to the neutral/ground terminal of the circuit.
  3. اقرأ المجلدtagقيمة e على شاشة LCD.

For variable frequency voltage measurements, activate the Low-Pass Filter (LPF) function by pressing the LPF button (refer to Video 1, segment 00:55 for demonstration).

6.3. قياس المقاومة

لقياس المقاومة:

  1. Turn the rotary switch to the Ω (Resistance) position.
  2. Ensure the circuit is de-energized before connecting the test leads across the component to be measured.
  3. اقرأ قيمة المقاومة على شاشة LCD.

Refer to Video 1, segment 01:15 for a demonstration of 10MΩ resistance measurement.

6.4. قياس السعة

لقياس السعة:

  1. Turn the rotary switch to the capacitance (usually shared with resistance or diode) position and press SELECT if necessary to choose capacitance.
  2. Ensure the capacitor is fully discharged before connecting the test leads across its terminals.
  3. اقرأ قيمة السعة على شاشة LCD.

6.5. قياس التردد

لقياس التردد:

  1. Turn the rotary switch to the Hz (Frequency) position. This may be combined with voltage or current functions, requiring the Hz button to be pressed.
  2. Connect the test leads to the circuit for voltage frequency, or use the clamp for current frequency.
  3. اقرأ قيمة التردد على شاشة LCD.

Refer to Video 1, segment 01:45 for a demonstration of frequency measurement.

6.6. قياس درجة الحرارة

لقياس درجة الحرارة:

  1. Turn the rotary switch to the °C/°F (Temperature) position.
  2. Connect the appropriate temperature probe (if included or purchased separately) to the meter's input jacks.
  3. Place the probe tip on the surface or in the medium whose temperature is to be measured.
  4. اقرأ قيمة درجة الحرارة على شاشة LCD.

Refer to Video 1, segment 01:12 for a demonstration of high-precision temperature measurement using a blackbody heat source.

6.7. قياس الصمام الثنائي

لإجراء اختبار ثنائي:

  1. Turn the rotary switch to the diode (usually shared with resistance or continuity) position and press SELECT if necessary to choose diode.
  2. قم بتوصيل سلك الاختبار الأحمر بالأنود وسلك الاختبار الأسود بالكاثود للدايود.
  3. قراءة إلى الأمام المجلدtage drop on the LCD display. Reverse the leads to check for open circuit.

Refer to Video 1, segment 01:23 for a demonstration of diode measurement.

6.8. مجلد عدم الاتصالtagكشف (NCV).

لاستخدام وظيفة NCV:

  1. أدر المفتاح الدوار إلى وضع NCV.
  2. Move the NCV sensing end of the meter close to the conductor or electrical outlet.
  3. سيشير العداد إلى وجود جهد التيار المترددtage through a multi-segment display, audible beeps, and visual alarms.

Refer to Video 1, segment 01:27 for a demonstration of non-contact voltagالقياس.

6.9. قياس تيار البدء

لقياس تيار الاندفاع:

  1. Turn the rotary switch to the ACA (AC Current) position.
  2. Press the INRUSH button.
  3. Clamp the meter around the single live conductor of the device you wish to test.
  4. Turn on the device. The meter will capture and display the peak inrush current.

Refer to Video 1, segment 01:42 for a demonstration of measuring the starting current of a single-phase motor.

7. الصيانة

7.1. التنظيف

  • امسح العداد جasing مع لينة، damp قماش. لا تستخدم المواد الكاشطة أو المذيبات.
  • Keep the input terminals and rotary switch clean and free from dust or debris.

7.2. استبدال البطارية

Replace the battery when the low battery indicator appears on the display to ensure accurate measurements. Refer to section 5.1 for battery installation instructions.

7.3. التخزين

When not in use for extended periods, remove the battery and store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

8. استكشاف الأخطاء وإصلاحها

If the meter does not function correctly, check the following common issues:

  • لا يوجد عرض أو عرض خافت: Check battery level and replace if necessary. Ensure battery is installed with correct polarity.
  • تم عرض "OL" (الحمل الزائد): The input value exceeds the selected range. Select a higher range or ensure the measurement is within the meter's capabilities.
  • قراءات غير دقيقة: Ensure test leads are properly connected and not damaged. Verify the correct function and range are selected. Clean input terminals.
  • لا يوجد كشف لسرعة التوصيل العصبي: Ensure the NCV function is selected and the sensing end is close enough to the AC voltagالمصدر هـ.

إذا استمرت المشاكل، فاتصل بدعم عملاء UNI-T للحصول على المساعدة.

9. ماذا يوجد في الصندوق

The UNI-T UT205E Digital Clamp Meter package typically includes:

  • UNI-T UT205E Digital Clamp متر
  • اختبار الأسلاك
  • بطارية ليثيوم معدنية واحدة
  • حقيبة الحمل
  • دليل المستخدم

10. الضمان والدعم

للحصول على معلومات الضمان أو الدعم الفني أو الاستفسارات المتعلقة بالخدمة، يرجى الرجوع إلى موقع UNI-T الرسمي webالموقع أو تواصل مع موزعك المحلي. احتفظ بإيصال الشراء كإثبات للشراء في حال وجود أي مطالبات بالضمان.

المستندات ذات الصلة - UT205E

قبلview UNI-T UT205E/UT206B/UT207B/UT208B 1000A True RMS Digital Clamp دليل تشغيل العداد
دليل تشغيل شامل لأجهزة UNI-T UT205E وUT206B وUT207B وUT208B 1000A True RMS Digital Clamp العدادات. يغطي هذا الدليل الميزات، وتعليمات السلامة، والرموز الكهربائية، والهيكل الخارجي، وشاشة LCD، وأدوات التحكم في الوظائف، والمواصفات، وتعليمات التشغيل التفصيلية لمختلف القياسات، وإجراءات الصيانة.
قبلview جهاز قياس متعدد رقمي UNI-T UT161E True RMS - المواصفات والميزات
معلومات تفصيلية عن جهاز القياس الرقمي المتعدد UNI-T UT161E True RMS، بما في ذلك ميزاته ومواصفاته وتقييمات السلامة ومحتويات العبوة. مثالي لقياس الجهد بدقة في التيار المتردد/المستمرtagقياسات التيار والمقاومة والتردد والسعة.
قبلview UNI-T UT210E برو ميني CLamp دليل تشغيل العداد
توفر هذه الوثيقة دليل تشغيل شامل لجهاز UNI-T UT210E PRO Mini Clamp العداد، مع تفصيل مميزاته، واحتياطات السلامة، والمواصفات الفنية، وتعليمات التشغيل لمختلف القياسات الكهربائية.
قبلview UNI-T UT211A/B Mini Digital Clamp دليل مستخدم العداد
دليل المستخدم الشامل لجهاز UNI-T UT211A/B Mini Digital Clamp عداد، يتضمن تفاصيل المواصفات وتعليمات السلامة وإجراءات التشغيل والصيانة لإجراء قياسات كهربائية دقيقة.
قبلview سلسلة UNI-T UT210 Mini Clamp العدادات: المواصفات والميزات
المواصفات والميزات التفصيلية لسلسلة UNI-T UT210 من أجهزة التنظيف المصغرةamp العدادات، بما في ذلك التيار المتردد/المستمر، والفولتيةtagقياسات التيار الكهربائي، والمقاومة، والتردد، والسعة، ودرجة الحرارة. مثالي لفنيي الكهرباء والصيانة.
قبلview UNI-T UT201+/UT202+/UT202A+ AC Clamp دليل مستخدم العداد
دليل المستخدم الشامل لأجهزة UNI-T UT201+ وUT202+ وUT202A+ AC Clamp العدادات. يغطي هذا القسم الميزات، وتعليمات السلامة، وإجراءات التشغيل، والمواصفات الفنية، والصيانة لهذه الفئة من عدادات القيمة الفعّالة الحقيقية (True RMS).amp متر.