This manual provides essential information for the safe and efficient operation of your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater. Please read all instructions carefully before installation, operation, or maintenance. Retain this manual for future reference.

ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater

الصورة: الجبهة view of the ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, showcasing its compact design and infrared heating plaques.

معلومات السلامة

Your ProCom heater is designed with safety in mind. It is a ventless unit, meaning it does not require an outside duct or chimney. However, proper ventilation is still crucial for safe operation. This heater is equipped with an Oxygen Depletion Sensor (ODS) that automatically shuts down the unit if oxygen levels become too low. It is ANSI Certified to ensure safety standards are met.

مميزات المنتج

ProCom MN180TPA-B Features Diagram

Image: Diagram highlighting key features of the ProCom heater, including BTU output, ventless operation, natural gas compatibility, no electricity requirement, safety features, Piezo ignition, and thermostat mode.

يثبت

The ProCom MN180TPA-B heater offers flexible installation options: wall-mounted or floor-standing.

فك التعبئة والتفتيش

اختيار الموقع

Select a location that allows for proper clearances from combustible materials. Ensure the area has adequate ventilation as per local codes and the heater's specifications.

خيارات التثبيت

الوقوف على الأرض: Attach the included base feet to the bottom of the heater using the provided hardware. Ensure the heater is stable and level.

التثبيت على الحائط: Use the included wall mounting bracket and hardware. Follow the detailed instructions in the manufacturer's full installation guide for secure wall attachment and proper clearances.

ProCom MN180TPA-B Included Components

Image: Components included with the ProCom heater, showing the main unit, base feet, wall bracket, and highlighting the Oxygen Depletion Sensor and natural gas operation.

ProCom MN180TPA-B Wall Mounted

Image: The ProCom MN180TPA-B heater mounted on a wall in a living space, demonstrating its compact profile and integration into a room.

توصيل الغاز

This heater operates on natural gas only. Connection to the natural gas supply must be performed by a qualified professional in accordance with all local codes and regulations. Ensure all connections are leak-tested before operation.

تعليمات التشغيل

Follow these steps to safely operate your ProCom MN180TPA-B heater.

إجراءات التشغيل

  1. تأكد من فتح صمام إمداد الغاز.
  2. Turn the control knob to the 'PILOT' position.
  3. Press and hold the control knob in while simultaneously pressing the Piezo ignition button repeatedly until the pilot flame ignites.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit.
  5. If the pilot does not remain lit, repeat steps 2-4.
  6. Once the pilot is stable, turn the control knob to the desired heat setting (1-5). The main burner will ignite.

التحكم في الترموستات

The heater features a thermostat control with 5 variable heat settings. Rotate the control knob to select your preferred heat output. The heater will cycle on and off to maintain the set temperature.

ProCom MN180TPA-B Thermostat Controls

الصورة: عن قرب view of the control panel on the ProCom heater, showing the Piezo ignitor button and the rotary knob for 5 variable heat settings and pilot control.

إيقاف تشغيل المدفأة

  1. أدر مقبض التحكم إلى وضع "إيقاف التشغيل".
  2. For prolonged shutdown, close the main gas supply valve to the heater.

صيانة

تضمن الصيانة المنتظمة طول عمر السخان وتشغيله بشكل آمن.

استكشاف الأخطاء وإصلاحها

If you encounter issues with your heater, refer to the following common problems and solutions. For persistent issues, contact a qualified service technician.

مشكلةالسبب المحتملحل
لن يضيء الطيارNo gas supply; Air in gas line; Pilot orifice clogged; Faulty thermocoupleCheck gas supply; Purge air from line; Clean pilot orifice; Contact technician
Pilot lights but will not stay litThermocouple not heating sufficiently; Loose thermocouple connection; Faulty ODS pilot assemblyHold knob longer; Tighten connection; Contact technician
Main burner will not ignitePilot not lit; Main burner orifice clogged; Low gas pressureEnsure pilot is lit; Clean burner orifice; Contact gas provider/technician
Heater cycles off frequentlyInsufficient ventilation; ODS activation; Thermostat setting too high for room sizeIncrease ventilation; Check for obstructions; Adjust thermostat setting

تحديد

يصفالتفاصيل
ماركةProCom
رقم الموديلMN180TPA-B
نوع الوقودالغاز الطبيعي
Maximum BTU Output18,000 وحدة حرارية بريطانية
تغطية التدفئةتصل إلى 950 قدم مربع.
نوع الإشعالPush Button Piezo
نوع التحكمThermostat (High/Medium/Low)
ميزات السلامةOxygen Depletion Sensor (ODS)
خيارات التركيبWall Mount, Floor Standing (Base Feet Included)
أبعاد المنتج8 بوصة عمق × 22 بوصة عرض × 26 بوصة ارتفاع
وزن العنصر26.2 رطل
لونأبيض
الشهاداتCSA Certified, ANSI Certified
ProCom MN180TPA-B Dimensions Diagram

Image: Diagram illustrating the dimensions of the ProCom MN180TPA-B heater: 24 inches H, 19 inches L, and 8 inches D.

معلومات الضمان

For detailed warranty information regarding your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, please refer to the warranty card included with your product packaging or visit the official ProCom webقد تختلف شروط وأحكام الضمان.

دعم العملاء

If you require assistance, have questions about your heater, or need to report an issue, please contact ProCom customer support. Refer to your product packaging or the official ProCom website for the most current contact information, including phone numbers, email addresses, and online support resources.

المستندات ذات الصلة - MN180TPA-B

قبلview دليل مستخدم جهاز Procom NEW PRO-9900 AM/FM Citizens Band 2-Way Radio
دليل المستخدم لجهاز Procom NEW PRO-9900 AM/FM Citizens Band 2-Way Radio، يوضح بالتفصيل وظائفه وعملياته وميزاته والمواصفات الفنية للاستخدام الأمثل.
قبلview PROCOM Atlas Loud Mouth Digital Wireless Intercom User Manual
This user manual provides comprehensive information on the PROCOM Atlas Loud Mouth Digital Wireless Intercom, including its features, operation, specifications, safety guidelines, and FCC compliance.
قبلview ProCom Heating Vent-Free Gas Space Heater: Operation and Installation Manual
Comprehensive guide for ProCom Heating vent-free gas space heaters, covering installation, operation, safety, maintenance, and troubleshooting for models MN180TPA-B, ML150TPA-B, MN300TPA-B, and ML250TPA-B.
قبلview دليل المالك لتشغيل وتركيب سخان الغاز الحائطي بدون فتحة تهوية من ProCom
يقدم هذا الدليل تعليمات تشغيل وتركيب سخانات ProCom الجدارية الغازية بدون فتحة تهوية، بما في ذلك الطرازات MN2PHG، MN2PTG، MN3PHG، MN3PTG، ML2PHG، ML2PTG، ML3PHG، وML3PTG. ويغطي احتياطات السلامة، وميزات المنتج، والمواصفات، وإجراءات التركيب، والتشغيل، واستكشاف الأخطاء وإصلاحها، وقطع الغيار، والملحقات، ومعلومات الضمان.
قبلview قائمة قطع غيار الوحدة الداخلية من سلسلة Bosch Climate 5000AA
قائمة تفصيلية لقطع الغيار والرسم التخطيطي لوحدة Bosch Climate 5000AA Series الداخلية، بما في ذلك أرقام الأجزاء ومعلومات التوافق لمختلف سعات BTU.
قبلview ProCom Heating Vent-Free Gas Log Heater Manual
This manual provides comprehensive installation, operation, safety, and maintenance instructions for ProCom Heating Vent-Free Gas Log Heater models PCNSD18T, PCNSD24TD, and PCNSD24M. Learn how to safely install and use your gas log heater.