1. المقدمة

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Senville AURA Series Mini Split Air Conditioner Heat Pump. Please read this manual thoroughly before operating the unit to ensure proper use and to prevent damage.

The Senville AURA Series is designed to provide efficient cooling and heating for various spaces, including individual rooms, additions, garages, and commercial applications. It features DC Inverter Technology for high efficiency and quiet operation.

Senville AURA Series 48000 BTU Five Zone Mini Split Air Conditioner Heat Pump system, showing outdoor condenser, five indoor air handlers, remote controls, and installation accessories.

Figure 1.1: Complete Senville AURA Series Mini Split System Components.

2. معلومات السلامة

Always adhere to the following safety precautions to reduce the risk of fire, electric shock, injury, or property damage.

  • يجب أن يتم التركيب بواسطة أفراد مؤهلين وفقًا لجميع القوانين المحلية والوطنية المعمول بها.
  • تأكد من أن مصدر الطاقة يطابق مواصفات الوحدة (208-230 فولت).
  • لا تقم بإدخال أصابعك أو أي أشياء في مدخل/مخرج الهواء.
  • لا تحاول إصلاح الجهاز بنفسك. اتصل بفنيي الصيانة المؤهلين.
  • قم بإيقاف تشغيل مصدر الطاقة قبل التنظيف أو إجراء الصيانة.

3. مكونات المنتج

The Senville AURA Series SENA-48HF/F system includes the following main components:

  • (5) 9000 BTU Indoor Air Handlers
  • (1) 48000 BTU Outdoor Condenser
  • أجهزة تحكم عن بعد لاسلكية (جهاز واحد لكل وحدة داخلية)
  • Pre-charged refrigerant lines (up to 125 ft)
  • Installation accessories (drain hoses, electrical wiring, insulation tape)
Close-up of a single Senville AURA Series indoor air handler unit.

Figure 3.1: Indoor Air Handler Unit.

Senville AURA Series remote control with LCD display and various function buttons.

Figure 3.2: Wireless Remote Control.

Installation kit components including insulated copper lines, electrical cable, and tape.

Figure 3.3: Included Installation Accessories.

4. التثبيت والإعداد

Installation of the Senville AURA Series mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC technician.

4.1 قائمة التحقق من التثبيت المسبق

  • تأكد من أن جميع المكونات موجودة وغير تالفة.
  • تأكد من توفير مساحة كافية للوحدات الداخلية والخارجية، مما يسمح بتدفق الهواء المناسب وسهولة الوصول للصيانة.
  • Confirm electrical supply meets 208-230V requirements and dedicated circuit is available.

4.2 خطوات التثبيت (أكثر منview (للفني)

  1. Mount indoor air handlers in desired locations, ensuring proper drainage.
  2. Position the outdoor condenser unit on a stable, level surface, away from obstructions.
  3. Connect refrigerant lines between indoor and outdoor units. The system is pre-charged for up to 125 feet of line.
  4. Connect electrical wiring according to the wiring diagram provided in the full installation manual.
  5. قم بتنظيف أنابيب التبريد بالمكنسة الكهربائية لإزالة الهواء والرطوبة.
  6. Check for leaks using appropriate methods.
  7. Open service valves to release refrigerant.
  8. اختبر النظام للتأكد من تشغيله بشكل صحيح في كل من وضعي التبريد والتدفئة.

5. تعليمات التشغيل

Your Senville AURA Series system is designed for user-friendly operation via the wireless remote control.

5.1 وظائف التحكم عن بعد

Refer to Figure 3.2 for a visual guide to the remote control buttons.

  • زر الطاقة: يقوم بتشغيل / إيقاف تشغيل الوحدة.
  • زر الوضع: يتنقل بين أوضاع التشغيل التالية: تلقائي، تبريد، تجفيف، تدفئة، مروحة.
  • ضبط درجة الحرارة: استخدم الأسهم لأعلى/لأسفل لضبط درجة الحرارة المطلوبة.
  • سرعة المروحة: يضبط سرعة المروحة (تلقائي، منخفض، متوسط، عالي).
  • تأرجح: يتحكم في حركة فتحات التهوية لتوزيع الهواء.
  • معدات صديقة للبيئة: يقوم بتنشيط وضع توفير الطاقة.
  • المؤقت: يضبط مؤقتات التشغيل/الإيقاف للتشغيل المجدول.

أوضاع التشغيل 5.2

  • وضع بارد: Provides cooling. Ideal for summer months.
  • وضع الحرارة: Provides heating. Effective down to -22°F (-30°C) with Arctic Heat Pump technology.
  • وضع الجاف: يزيل الرطوبة من الهواء.
  • وضع المروحة: يقوم بتدوير الهواء دون تسخين أو تبريد.
  • نظام آلي: Automatically selects cooling or heating based on ambient temperature.
Diagram illustrating the wide operating temperature range of the Senville AURA system, from -22°F with Arctic Heat Pump to 122°F with Inverter Heat Pump.

Figure 5.1: Operating Temperature Range.

5.3 الميزات الذكية

  • Whisper Technology: Ensures quiet operation, with noise levels as low as 23.5 dB.
  • Smart Saving: Built-in intelligent eye detects human movement to automatically adjust operation and save energy.
  • عناصر التحكم الذكية: Compatible with voice control (e.g., Alexa) and app control (requires Alexa Kit installation).
Graph comparing Senville AURA noise levels to other common sounds like library and normal talk, highlighting its quiet operation.

الشكل 5.2: التشغيل بضوضاء منخفضة.

Image showing 'Nobody Detected Lower Energy Consumption' and 'Smart Saving' features, indicating energy efficiency.

Figure 5.3: Smart Saving Feature.

Two women using smart devices to control the mini split, with text 'Alexa, set my mini split to cooling.' and 'Alexa Kit Must Be Installed'.

Figure 5.4: Smart Controls with Alexa Integration.

6. الصيانة

Regular maintenance ensures optimal performance and longevity of your Senville AURA system.

6.1 تنظيف المرشح

  • Clean air filters every two weeks or more frequently depending on usage and air quality.
  • Open the front panel of the indoor unit, remove filters, and wash with lukewarm water.
  • اترك المرشحات لتجف تمامًا قبل إعادة إدخالها.

6.2 صيانة الوحدة الخارجية

  • حافظ على المنطقة المحيطة بالوحدة الخارجية خالية من الحطام والأوراق والثلوج.
  • Periodically clean the outdoor coil with a soft brush or vacuum cleaner.
  • Ensure proper drainage from the outdoor unit.

6.3 الخدمة المهنية

It is recommended to have a certified HVAC technician perform annual inspections and maintenance, including checking refrigerant levels, electrical connections, and overall system performance.

7. استكشاف الأخطاء وإصلاحها

قبل الاتصال بدعم العملاء، يرجى الرجوع إلى المشكلات والحلول الشائعة التالية:

مشكلةالسبب المحتملحل
الوحدة لا تعمل.لا يوجد كهرباء، بطاريات جهاز التحكم عن بعد فارغة، قاطع الدائرة الكهربائية مفصول.افحص مصدر الطاقة، واستبدل بطاريات جهاز التحكم عن بعد، وأعد ضبط قاطع الدائرة.
عدم كفاية التبريد/التدفئة.فلاتر هواء متسخة، وحدة خارجية مسدودة، ضبط غير صحيح للوضع، انخفاض مستوى غاز التبريد.نظف الفلاتر، وأزل أي عوائق، واختر الوضع الصحيح، واتصل بالفني لفحص غاز التبريد.
ضوضاء غير عادية.الأجزاء المفكوكة، انسداد المروحة، أصوات التشغيل العادية (مثل تدفق غاز التبريد).Inspect for loose parts, remove obstructions. If persistent or loud, contact technician.
تسرب المياه من الوحدة الداخلية.خرطوم تصريف مسدود، تركيب غير صحيح.Check and clear drain hose. If issue persists, contact technician.

8. المواصفات الفنية

ميزةمواصفة
رقم الموديلSENA-48HF/F
سعة48000 وحدة حرارية بريطانية (4 طن)
الوحدات الداخلية(5) 9000 BTU Air Handlers
الوحدة الخارجية(1) 48000 BTU Condenser
المجلدtage208-230 Volts
الكفاءة (الرائي)22.0
مستوى الضوضاء (داخلي)23.5 dB (Whisper Technology)
أبعاد المنتج48"D x 48"W x 60"H (Overall System)
المميزات الخاصةHeating and Cooling Function, DC Inverter Technology, Smart Saving, Smart Controls (Alexa compatible)
الشهاداتETL Intertek Approved, AHRI Certified, ENERGYSTAR

9. معلومات الضمان

The Senville AURA Series is backed by a comprehensive warranty:

  • ضمان قطع الغيار: سنتان
  • ضمان الضاغط: سنتان

For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Senville webموقع.

10. دعم العملاء

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Senville customer support.

  • Webموقع: Visit the Senville Store on Amazon
  • الاستفسارات العامة: Refer to the contact information provided in your product packaging or on the official Senville webموقع.
Illustration of a customer support representative with a headset, indicating 24/7 customer support.

Figure 10.1: Senville Customer Support.

المستندات ذات الصلة - SENA-48HF/F

قبلview دليل مالك مكيف الهواء المنفصل من Senville
يُقدّم دليل المالك هذا معلومات أساسية لتركيب وتشغيل وصيانة وإصلاح أعطال مكيف الهواء المنفصل من نوع سينفيل. تعرّف على احتياطات السلامة والميزات والصيانة لضمان الأداء الأمثل وطول عمر جهازك.
قبلview دليل المستخدم ودليل السلامة لمكيف الهواء المنفصل من نوع سينفيل
دليل المالك الشامل لأجهزة تكييف الهواء المنفصلة من نوع Senville، والذي يغطي احتياطات السلامة والتشغيل والصيانة واستكشاف الأخطاء وإصلاحها وإرشادات التثبيت لطرازات مثل CS019UI-EP(R454B).
قبلview دليل المالك ودليل التركيب لمكيف الهواء المنفصل من Senville
دليل شامل للمالك ودليل تركيب مكيفات الهواء المنفصلة من نوع سينفيل (SENA/09HF/IQ، SENA/09HF/OQ، SENA/12HF/IQ، SENA/12HF/OQ، SENA/18HF/IQ، SENA/18HF/OQ، SENA/24HF/IQ، SENA/24HF/OQ). يغطي الدليل جوانب السلامة والتشغيل والصيانة والتركيب.
قبلview دليل المالك والتركيب لمكيف الهواء المنفصل من نوع Senville
يوفر هذا الدليل تعليمات شاملة لمكيف الهواء المنفصل من نوع Senville، ويغطي احتياطات السلامة وتفاصيل دليل المالك والعناية والصيانة واستكشاف الأخطاء وإصلاحها وإجراءات التثبيت للطرازات SENA/09HF وSENA/12HF وSENA/18HF وSENA/24HF.
قبلview دليل المالك والتركيب لمكيف الهواء المنفصل من نوع سينفيل
يُقدّم هذا الدليل تعليماتٍ مُفصّلة لتركيب وتشغيل وصيانة واستكشاف أعطال مكيفات الهواء المنفصلة من نوع سينفيل، ويشمل الطرازات التالية: SENA/09HF/IQ، SENA/09HF/OQ، SENA/12HF/IQ، SENA/12HF/OQ، SENA/18HF/IQ، SENA/18HF/OQ، SENA/24HF/IQ، وSENA/24HF/OQ. ويتضمن إرشادات السلامة والمواصفات الفنية.
قبلview مجموعات الوحدات الداخلية المتوافقة مع أنظمة Senville متعددة المناطق
دليل لمجموعات الوحدات الداخلية المتوافقة مع أنظمة التدفئة والتهوية وتكييف الهواء متعددة المناطق من Senville، مع تفاصيل الخيارات لمنطقتين إلى خمس مناطق مع نماذج مكثف خارجية مختلفة.