1. المقدمة
This manual provides comprehensive instructions for the OWON XSA805-TG Spectrum Analyzer. It covers the device's features, setup, operation, and maintenance to ensure safe and efficient use. The XSA805-TG is a high-performance spectrum analyzer designed for various signal analysis applications, featuring a 9-inch LCD, a frequency range of 9 kHz to 500 MHz, and a tracking generator.
2. معلومات السلامة
Please read all safety instructions carefully before operating the device. Failure to follow these instructions may result in injury or damage to the instrument.
- مزود الطاقة: Use only the specified power adapter. Ensure the power source matches the voltage requirements of the instrument.
- بيئة: Operate the device in a dry, well-ventilated area. Avoid exposure to extreme temperatures, humidity, dust, or corrosive gases.
- تهوية: Do not block the ventilation openings on the instrument. Adequate airflow is essential to prevent overheating.
- الاتصالات: Ensure all connections are secure before powering on the device. Disconnect power before making or changing connections.
- الخدمة: Do not attempt to service the instrument yourself. Refer all servicing to qualified service personnel.
- تنظيف: Clean the instrument with a soft, dry cloth. Do not use liquid or aerosol cleaners.
3. انتهى المنتجview
The OWON XSA805-TG Spectrum Analyzer is equipped with a 9-inch LCD and various interfaces for comprehensive signal analysis. Below are the key components and their functions.
3.1 اللوحة الأمامية

The front panel features the main display, control buttons, numeric keypad, and input/output ports.
- Menu Softkeys: Context-sensitive buttons for menu navigation.
- مفاتيح الوظائف: Dedicated buttons for common functions like SPAN, RBW, Trace, etc.
- مقبض الباب: Rotary encoder for adjusting parameters and navigating menus.
- مفاتيح السهم: For precise cursor movement and parameter selection.
- المفاتيح العددية: For direct entry of numerical values.
- مفتاح التشغيل: لتشغيل الجهاز أو إيقاف تشغيله.
- USB Host Interface: لتوصيل أجهزة تخزين USB أو الأجهزة الطرفية الأخرى.
- واجهة السماعة: لإخراج الصوت.
- Tracking Generator Output (optional): Output for the tracking generator function.
- موصل إدخال الترددات اللاسلكية: Main input for RF signals.
3.2 اللوحة الخلفية

The rear panel provides additional connectivity options and power input.
- واجهة HDMI: لتوصيل شاشة خارجية.
- واجهة جهاز USB: For connecting the analyzer to a computer.
- موصل إدخال الزناد: لإشارات التشغيل الخارجية.
- إشارة الساعة المرجعية الداخلة/الخارجة: لمزامنة الساعة الخارجية.
- واجهة LAN: للاتصال بالشبكة.
- موصل طاقة التيار المتردد: لتوصيل سلك الطاقة.
- Security Lock Hole: لتأمين الجهاز.
4. الإعداد
Follow these steps to set up your OWON XSA805-TG Spectrum Analyzer.
- فك التعبئة: Carefully remove the spectrum analyzer and all accessories from the packaging. Inspect for any signs of damage.
- توصيل الطاقة: Connect the provided AC power cord to the AC Power Connector on the rear panel and then to a suitable power outlet.
- التشغيل الأولي: Press the Power Key on the front panel to turn on the device. The system will boot up and display the main measurement interface.
- الاتصالات الخارجية (اختياري):
- جهاز USB:٪ s: Connect USB storage or other peripherals to the USB Host Interface.
- اتصال الكمبيوتر: Use a USB cable to connect the USB Device Interface to your computer for data transfer or remote control.
- العرض الخارجي: Connect an HDMI cable to the HDMI Interface for an external monitor.
- شبكة: Connect an Ethernet cable to the LAN Interface for network access.
5. تعليمات التشغيل
This section details the primary functions and operational modes of the XSA805-TG Spectrum Analyzer.
5.1 القياس الأساسي
Upon startup, the analyzer displays the default spectrum measurement screen. Use the function keys and softkeys to adjust parameters such as Center Frequency, Span, Resolution Bandwidth (RBW), and Video Bandwidth (VBW).
- تردد المركز: Sets the center frequency of the displayed spectrum.
- فترة: Defines the frequency range displayed around the center frequency.
- RBW (Resolution Bandwidth): Determines the frequency resolution of the measurement. A smaller RBW provides better resolution but increases sweep time.
- VBW (Video Bandwidth): Controls the bandwidth of the video filter, affecting trace smoothing.
5.2 Quick Capture Function
The quick capture function allows for rapid analysis of ASK/FSK modulated signals, directly providing center frequency, power, and offset parameters. This is particularly useful for analyzing signals from devices like car remote keys, TRMS tire pressure modules, and small wireless modules.

The image above illustrates the application of the quick capture function for various wireless devices.

This image highlights the 1 Hz minimum resolution bandwidth (RBW) capability, which effectively distinguishes nearby signals, crucial for detailed analysis in quick capture mode.
5.3 Extended Function Modes
The XSA805-TG offers multiple extended function modes for advanced analysis, including modulation signal quality analysis, audio demodulation, field strength measurement, channel measurement, and frequency counter.

The image above shows the interface for modulation signal quality analysis and audio demodulation.

This image displays the interfaces for channel measurement and the frequency counter, demonstrating the versatility of the analyzer.
5.4 EMI Test Function (Optional Software Required)
The device supports EMI pre-compliance testing with an optional software package. It includes over 200 mainstream EMC test standards and regulation templates. This allows users to select corresponding templates, and the software automatically configures the spectrum analyzer and records test data. Data and regulations can be compared on the same screen, and users can customize regulations for comparative analysis.

The image illustrates the EMI test software interface, showing measurement parameters and a graphical display of test results.
6. المواصفات
The following table outlines the key technical specifications for the OWON XSA805-TG Spectrum Analyzer.

This image provides a detailed comparison of specifications across the XSA800 series, including the XSA805-TG model.
| ميزة | مواصفة |
|---|---|
| أبعاد المنتج | 20.28 × 10.43 × 13.78 بوصة |
| وزن | 11.02 رطل |
| عرض | 9-inch LCD, 1280x800 Pixels |
| نطاق التردد | 9 كيلوهرتز - 500 ميجاهرتز |
| مستوى الضوضاء المتوسط المعروض (DANL) | -160 ديسيبل |
| ضجيج المرحلة | -80 dBc/Hz @ 1 GHz and offset at 10 kHz |
| Minimum Resolution Bandwidth (RBW) | 1 هرتز |
| الواجهات | USB Host, USB Device, LAN, Earphone, HDMI |
7. الصيانة
Proper maintenance ensures the longevity and optimal performance of your spectrum analyzer.
- تنظيف: Regularly clean the exterior of the instrument with a soft, dry, lint-free cloth. Do not use abrasive cleaners or solvents. For the display, use a screen-specific cleaner if necessary, applied to the cloth, not directly to the screen.
- تخزين: When not in use, store the analyzer in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a protective case if available.
- معايرة: For critical measurements, periodic calibration by qualified service personnel is recommended to maintain accuracy.
- تحديثات البرامج: Check the OWON official website for any available firmware or software updates to ensure your device has the latest features and bug fixes.
8. استكشاف الأخطاء وإصلاحها
This section provides solutions to common issues you might encounter with your OWON XSA805-TG.
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| الجهاز لا يعمل | Power cord not connected; Power outlet faulty; Device fault. | Check power cord connection; Test power outlet; Contact support if issue persists. |
| لم يتم عرض أي إشارة | Input signal cable disconnected; Input signal too weak; Incorrect frequency settings. | Verify signal cable connection; Ensure signal source is active; Adjust Center Frequency and Span. |
| الشاشة متجمدة أو غير مستجيبة | Software error; Temporary glitch. | Restart the device by holding the power button; If persistent, check for firmware updates. |
| لم يتم التعرف على جهاز USB | USB device incompatible; Faulty USB port. | Try a different USB device; Use a different USB port; Ensure device is formatted correctly. |
If you encounter problems not listed here or if the suggested solutions do not resolve the issue, please contact OWON customer support.
9. الضمان والدعم
OWON provides a limited warranty for its products. Please refer to the warranty card included with your product or visit the official OWON webالموقع للحصول على شروط وأحكام الضمان التفصيلية.
For technical support, service, or inquiries, please contact OWON customer service through the following channels:
- OWON Official Webموقع: www.owon.com (Check for support contact information, FAQs, and software downloads)
- مراكز الخدمة المعتمدة: A list of authorized service centers may be available on the OWON webموقع.