1. المقدمة
This instruction manual provides essential information for the safe and correct installation and use of the ALLIANCE LAUNDRY SYSTEMS LP Gas Conversion Kit, model 458P3. This kit is designed to convert specific natural gas (NG) dryers to operate on liquid propane (LP) gas. Proper installation is critical for safety and appliance performance.
This kit is compatible with various dryer brands including Ipso, Huebsch, Speed Queen, Unimac, Econo-Wash, Primus, and other Alliance Laundry Systems models.
2. معلومات السلامة
تحذير: قد يؤدي التركيب غير الصحيح أو الضبط أو التغيير أو الخدمة أو الصيانة إلى تلف الممتلكات أو الإصابة أو الوفاة. اقرأ إرشادات التثبيت والتشغيل والصيانة بدقة قبل تثبيت هذا الجهاز أو صيانته.
- Installation must be performed by a qualified service technician or gas installer.
- Ensure the gas supply to the dryer is turned off before beginning any conversion procedures.
- Disconnect electrical power to the dryer before installation.
- Always check for gas leaks after conversion using a non-corrosive leak detection solution. Never use an open flame.
- تأكد من توفير تهوية كافية أثناء وبعد التركيب.
- أبقِ المواد القابلة للاشتعال بعيداً عن المجفف.
3. محتويات المجموعة
The ALLIANCE LAUNDRY SYSTEMS LP Gas Conversion Kit 458P3 includes the necessary components for converting your dryer from natural gas to liquid propane.

Image 1: Components of the LP Gas Conversion Kit 458P3. This image displays two brass gas orifices (one with a white plastic tip, one without) and several white adhesive labels. The labels are printed with conversion information in English, French, and Spanish, indicating the dryer has been converted to LP gas, along with spaces for date, kit number (458P3), installer's name, and address. Other labels specify orifice size (#53), BTU/hour (25,000), and manifold/inlet pressure settings for LP gas.
The kit typically contains:
- One (1) LP gas orifice, size #53.
- Conversion labels for the dryer's rating plate and control panel.
4. الإعداد والتثبيت
4.1 خطوات ما قبل التثبيت
- Ensure the dryer is disconnected from the electrical supply and the natural gas supply valve is closed.
- Verify that the area is well-ventilated.
- Gather necessary tools, which may include wrenches, screwdrivers, and a gas leak detection solution.
- Locate the dryer's gas valve and burner assembly. Refer to your dryer's specific service manual for detailed component locations.
4.2 إجراء التحويل
- Replace Orifice: Carefully remove the existing natural gas orifice from the burner assembly. Install the new LP gas orifice, size #53, provided in this kit. Ensure it is securely tightened to prevent leaks.
- Adjust Pressure Regulator: Locate the gas pressure regulator on the dryer's gas valve. Adjust the regulator for LP gas operation. The manifold pressure for LP gas should be set to 10.5 inches Water Column (W.C.). The inlet pressure should be between 8.5 inches W.C. (minimum) و 11.5 inches W.C. (maximum). Consult your dryer's service manual for specific regulator adjustment instructions.
- Apply Conversion Labels: Affix the provided conversion labels to the dryer. One label should be placed near the existing rating plate, and another on the control panel, as indicated by the label instructions. These labels confirm the dryer has been converted to LP gas. Fill in the date of conversion, kit number (458P3), and the name and address of the converting organization or individual.
- اختبار التسرب: After reassembling the dryer and reconnecting the LP gas supply, perform a thorough leak test on all gas connections using a non-corrosive leak detection solution. Bubbles indicate a leak. Tighten connections as needed and retest until no leaks are detected.
- تحقق من العملية: Reconnect electrical power. Turn on the LP gas supply. Operate the dryer through a full cycle to ensure proper ignition and heating. Observe the flame for proper appearance (blue, stable flame).
5. تعليمات التشغيل
After successful conversion and verification, operate your dryer according to its original operating manual. The primary change is the type of gas used. Always ensure proper ventilation and never operate the dryer if you detect a gas odor.
6. الصيانة
Regular maintenance of your LP gas dryer is similar to a natural gas dryer. Periodically:
- Inspect the gas supply line and connections for any signs of wear or leaks.
- نظف فلتر الوبر قبل أو بعد كل غسلة.
- Ensure the exhaust vent is clear of obstructions to maintain proper airflow and prevent fire hazards.
- For any issues related to gas components, contact a qualified service technician.
7. استكشاف الأخطاء وإصلاحها
If your dryer experiences issues after conversion, consider the following:
- No Heat or Weak Heat: Verify the LP gas supply is open and the tank is not empty. Check that the gas pressure regulator is correctly set to 10.5" W.C.
- رائحة الغاز: Immediately turn off the gas supply and disconnect power. Do not operate the dryer. Ventilate the area and contact a qualified service technician or your gas provider. Do not attempt to locate the leak yourself with an open flame.
- المجفف لا يبدأ: Ensure all electrical connections are secure and the dryer door is properly closed. This is typically not related to gas conversion.
For persistent problems, consult a qualified appliance technician.
8. المواصفات
| ميزة | مواصفة |
|---|---|
| رقم القطعة | 458 بكسل 3 |
| حجم الفتحة | #53 |
| وحدة حرارية بريطانية/ساعة | 25,000 |
| Manifold Pressure (LP) | 10.5" W.C. |
| Inlet Pressure (LP) | 8.5" W.C. (Min) - 11.5" W.C. (Max) |
| مادة | سبائك الفولاذ، الفولاذ المقاوم للصدأ |
| وزن العنصر | 4.3 أونصات |
| أبعاد الحزمة | 11.9 × 10.35 × 0.9 بوصة |
9. الضمان والدعم
For warranty information or technical support regarding the ALLIANCE LAUNDRY SYSTEMS LP Gas Conversion Kit 458P3, please refer to the documentation provided with your original dryer or contact ALLIANCE LAUNDRY SYSTEMS directly through their official webالموقع أو قنوات خدمة العملاء.