1. المقدمة
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Solaxx CLGE40 Resilience E Series 40K Gal All-in-1 system. Please read this manual thoroughly before attempting to install or operate the unit to ensure safe and efficient use.
The Solaxx CLGE40 is designed to provide efficient water treatment for pools up to 40,000 gallons, integrating multiple functions into a single, compact unit.
2. معلومات السلامة
Always observe the following safety precautions to reduce the risk of injury, electric shock, fire, or damage to the unit.
- السلامة الكهربائية: Ensure the unit is connected to a properly grounded outlet. Do not operate with damaged cords or plugs. Disconnect power before servicing.
- التعامل مع المواد الكيميائية: Follow all manufacturer's instructions for handling pool chemicals. Avoid direct contact with skin and eyes.
- تثبيت: يجب أن يتم التركيب بواسطة فني مؤهل وفقًا لجميع قوانين الكهرباء والسباكة المحلية والوطنية.
- جودة المياه: Maintain proper water chemistry as specified in this manual to ensure optimal performance and longevity of the unit.
- الأطفال والحيوانات الأليفة: احتفظ بالأطفال والحيوانات الأليفة بعيدًا عن الوحدة أثناء التشغيل والصيانة.
3. انتهى المنتجview

الشكل 3.1: الجبهة view of the Solaxx CLGE40 Resilience E Series 40K Gal All-in-1 unit. This image displays the main body of the unit, including the control panel with various indicators and buttons, and the transparent cell housing below.

الشكل 3.2: بزاوية view of the Solaxx CLGE40 Resilience E Series 40K Gal All-in-1 unit. This perspective provides a clearer view of the transparent cell, which allows for visual inspection, and the plumbing connection points on either side.
The CLGE40 system integrates a salt chlorine generator with advanced control features. Key components include the control unit, the electrolytic cell, and various sensors for optimal performance.
4. الإعداد والتثبيت
4.1 قائمة التحقق من التثبيت المسبق
- تأكد من أن جميع المكونات موجودة وغير تالفة.
- Ensure adequate space for installation and maintenance.
- Confirm power supply meets unit requirements (refer to specifications).
- Have necessary plumbing tools and materials ready.
4.2 تركيب السباكة
- Select an appropriate location in the return line after the filter and heater.
- Cut the existing PVC pipe and install the provided unions.
- Securely attach the electrolytic cell to the unions, ensuring proper flow direction as indicated on the cell.
- Apply PVC cement to all connections for a watertight seal. Allow adequate curing time.
4.3 التوصيل الكهربائي
- تأكد من فصل التيار الكهربائي من قاطع الدائرة.
- Connect the control unit to a dedicated, grounded electrical outlet or circuit as per local electrical codes.
- Connect the cell cable to the control unit.
- Do not restore power until all connections are secure and the system is filled with water.
5. تعليمات التشغيل
5.1 بدء التشغيل الأولي
- Ensure pool water chemistry is balanced (pH, alkalinity, calcium hardness).
- Add pool salt to achieve the recommended salinity level (typically 3000-3500 ppm). Allow salt to dissolve completely.
- قم بتشغيل مضخة حمام السباحة.
- Restore power to the Solaxx CLGE40 unit.
- Press the "ON/OFF" button to activate the unit.
5.2 Adjusting Chlorine Output
The unit features an adjustable output level to control chlorine production. Use the "+" and "-" buttons on the control panel to increase or decrease the output percentage. Monitor your pool's free chlorine level and adjust as needed to maintain desired sanitation.
5.3 مصابيح مؤشر
- تشغيل/إيقاف: يشير إلى حالة الطاقة.
- انتاج: Bar graph showing current chlorine production level.
- قليل الملح: Illuminates when salt level is below optimal. Add salt.
- لا تدفق: Indicates insufficient water flow through the cell. Check pump and plumbing.
- ماء بارد: Illuminates if water temperature is too low for efficient operation.
- CLEAN CELL: Indicates the cell requires cleaning.
- CELL LIFE LOW: Indicates the electrolytic cell is nearing the end of its lifespan and may need replacement soon.
6. الصيانة
6.1 تنظيف الخلايا
The electrolytic cell may accumulate scale deposits over time, reducing efficiency. The "CLEAN CELL" indicator will illuminate when cleaning is required.
- Turn off the unit and pool pump, and disconnect power.
- Remove the electrolytic cell from the plumbing.
- Prepare a cleaning solution of 1 part muriatic acid to 4 parts water in a plastic container. Always add acid to water, never water to acid.
- Submerge the cell plates in the solution, ensuring the electrical connections remain dry.
- Allow to soak until bubbling stops (typically 5-15 minutes). Do not over-soak.
- Rinse the cell thoroughly with fresh water.
- Reinstall the cell and restore power.
6.2 فصل الشتاء
In areas subject to freezing temperatures, the unit must be properly winterized to prevent damage.
- افصل الطاقة عن الوحدة.
- Drain all water from the electrolytic cell and plumbing lines connected to the unit.
- Remove the cell and store it in a dry, temperature-controlled environment.
7. استكشاف الأخطاء وإصلاحها
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| "LOW SALT" indicator on | Low salt level in pool water. | Test salt level and add salt as needed. Allow time for dissolution. |
| "NO FLOW" indicator on | Insufficient water flow through cell. | Check pool pump operation, filter cleanliness, and ensure valves are open. |
| "CLEAN CELL" indicator on | Scale buildup on cell plates. | Clean the electrolytic cell as per Section 6.1. |
| Low chlorine output | Low salt, dirty cell, low water temperature, or incorrect output setting. | Check salt level, clean cell, ensure water temperature is adequate, increase output setting. |
| الوحدة لا تعمل | No power supply, tripped breaker, or faulty connection. | Check power outlet, reset circuit breaker, ensure all electrical connections are secure. |
8. المواصفات
- نموذج: CLGE40 Resilience E Series
- أقصى حجم لحوض السباحة: 40,000 جالون
- الشركة المصنعة: سولاكس
- أبعاد الحزمة: 12 × 12 × 8 بوصة
- ASIN: B0B96WPR34
- Recommended Salt Level: 3000-3500 جزء في المليون
ملاحظة: المواصفات عرضة للتغيير دون إشعار.
9. الضمان والدعم
For warranty information, please refer to the warranty card included with your product or visit the official Solaxx webالموقع. احتفظ بإثبات الشراء الخاص بك لتقديم مطالبات الضمان.
For technical support, troubleshooting assistance, or to order replacement parts, please contact Solaxx Customer Service:
- Webموقع: www.solaxx.com
When contacting support, please have your product model number (CLGE40) and serial number ready.