1. انتهى المنتجview

The Suntree DC Molded Case Circuit Breaker is engineered to safeguard DC electrical installations from overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms for reliable protection. Upon detecting a fault, the circuit breaker automatically interrupts the electrical circuit, preventing wire damage and reducing fire risk. This device can also be manually opened under its full rated load for electrical maintenance without sustaining damage. Designed for reversible connection, the circuit breaker can be wired in either direction and supports bidirectional current flow. Clear markings on the handle indicate the contact position (ON/OFF) at a glance. Its design facilitates easy installation on both standard DIN rails and vertical surfaces.

رينوجي سانتري 160 Amp 2-Pole DC Circuit Breaker

Figure 1: Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

2. معلومات السلامة

  • Always disconnect power before installing or servicing the circuit breaker.
  • Installation should be performed by qualified personnel in accordance with local electrical codes and standards.
  • Ensure proper wire sizing and terminal connections to prevent overheating.
  • لا تقم بتشغيل قاطع الدائرة إذا كان يبدو تالفًا.
  • ارتدِ معدات الحماية الشخصية المناسبة عند العمل مع الأنظمة الكهربائية.

3. التثبيت

3.1 محتويات العبوة

  • 160A 2P DC Molded Case Circuit Breaker
  • مسامير التثبيت
  • Insulation Barrier (2 pieces)
Dimensions and included components of the circuit breaker

Figure 2: Product Dimensions and Included Components

3.2 التركيب

The circuit breaker supports both DIN rail and vertical surface mounting. Ensure the mounting location is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.

Diagram showing quick installation on DIN rail with insulation barriers

Figure 3: Quick Installation on DIN Rail

3.3 توصيلات الأسلاك

Connect the DC positive and negative cables to the corresponding terminals on the circuit breaker. The circuit breaker is designed for reversible connection and functions with bidirectional current. Ensure all connections are secure and tight. Install the provided insulation barriers between terminals for enhanced safety.

Wiring diagram showing positive and negative connections to the circuit breaker

الشكل 4: مخطط الاتصال

3.4 Sizing Tips for Circuit Breaker Selection

Proper sizing is crucial for effective protection.

  • For controller/inverter/DC device:
    1. Determine the maximum continuous operating current (current = watt/voltagهـ).
    2. Calculate maximum current = 1.25 x maximum continuous operating current.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
  • For solar panel:
    1. Determine the short-circuit current.
    2. Calculate maximum current = Short-circuit current x 1.25 x 1.25.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
Diagram illustrating sizing tips for circuit breakers in solar systems

Figure 5: Circuit Breaker Sizing Guidelines

4. التشغيل

4.1 تشغيل / إيقاف

To switch the circuit breaker ON, push the handle to the 'ON' position. To switch it OFF, push the handle to the 'OFF' position. The handle's position clearly indicates the contact status.

Image showing the ON and OFF positions of the circuit breaker handle

Figure 6: ON/OFF Markings

4.2 آليات الحماية

The circuit breaker provides protection against both overload and short-circuit conditions. In the event of an electrical fault, the breaker will automatically trip to protect the system.

Diagram illustrating overload and short-circuit protection features

Figure 7: Overload and Short-circuit Protection

5. الصيانة

After the circuit breaker has tripped due to a fault, it can be reset manually. No damage occurs to the breaker itself from tripping. Regular visual inspection for any signs of wear or damage is recommended. Ensure connections remain tight.

Diagram showing mechanical and electrical life cycles, and high electrical conductivity

Figure 8: Durability and Conductivity

6. استكشاف الأخطاء وإصلاحها

  • Breaker trips frequently: This indicates an overload or short circuit in the system. Identify and resolve the underlying electrical issue before resetting the breaker.
  • Breaker does not reset: Ensure the fault condition has been cleared. If the breaker still does not reset, it may be damaged and require replacement.
  • No power after installation: Verify all wiring connections are correct and secure. Check for proper input voltage and ensure the breaker is in the 'ON' position.

7. المواصفات

ميزةمواصفة
ماركةرينوجي
التقييم الحالي160 Amps
نوع قواطع دوائرمعيار
نوع التركيبالتركيب السطحي
عدد الاقطاب2
رمز المنتج الموحد810009719694
الشركة المصنعةرينوجي
رقم القطعةSUNDCCB160MC2P
وزن العنصر5.15 رطل
أبعاد المنتج7.9 × 3.5 × 5.3 بوصة
مادةنحاس
المكونات المضمنة160A 2P DC Molded Case Circuit Breaker, Mounting Screws, Insulation Barrier

8. الضمان والدعم

Renogy offers a 1-year material and workmanship warranty for this product. For technical support or warranty claims, please visit the official Renogy webالموقع أو الاتصال بخدمة العملاء الخاصة بهم.

لمزيد من المعلومات، قم بزيارة Renogy Store.

المستندات ذات الصلة - SUNDCCB160MC2P

قبلview Renogy Off-Grid Solar Kit General Manual: Installation and Operation Guide
This manual provides comprehensive instructions for installing, wiring, and maintaining the Renogy Off-Grid Solar Kit. Learn about safety precautions, mounting systems, battery configurations, and system connections for reliable off-grid power.
قبلview دليل مستخدم مجموعة الطاقة الشمسية خارج الشبكة من رينوجي: دليل التركيب والتوصيل والتثبيت
دليل مستخدم شامل لمجموعات الطاقة الشمسية خارج الشبكة من رينوجي، يغطي التركيب، والأسلاك، وأنظمة التركيب (قوس Z، والسكك الحديدية، والأعمدة)، وتكوينات البطارية، واحتياطات السلامة، واستخدام صمامات ANL للمركبات الترفيهية والقوارب وأنظمة الطاقة خارج الشبكة.
قبلview دليل المستخدم لـ Renogy Battery Shunt 300
دليل مستخدم شامل لجهاز Renogy Battery Shunt 300، يوفر إرشادات التثبيت والتشغيل والتكوين واستكشاف الأخطاء وإصلاحها لمراقبة البطارية الذكية في أنظمة الطاقة الشمسية والأنظمة خارج الشبكة.
قبلview Renogy ONE Core Quick Guide | Installation and Operation
A quick guide for the Renogy ONE Core (RSHGWSN-W02W-G3), covering installation, connection, and basic operation. Learn how to set up your Renogy ONE Core for optimal performance.
قبلview دليل المستخدم والمواصفات الفنية لوحدة بلوتوث Renogy BT-2
دليل شامل لوحدة Renogy BT-2 Bluetooth، يوضح بالتفصيل ميزاتها وتحديد الأجزاء والتشغيل والمواصفات الفنية والاتصال بالتطبيق لوحدات التحكم في شحن الطاقة الشمسية.
قبلview Renogy ONE Core User Manual: Comprehensive Guide to Energy Monitoring and Smart Home Integration
This user manual provides detailed instructions for the Renogy ONE Core, covering installation, operation, features like RV leveling and smart home integration, troubleshooting, and technical specifications. Learn how to monitor and manage your energy systems effectively.