This manual provides essential information for the safe and efficient installation, operation, and maintenance of your IBO BETA2 25-40/180 Hot Water Circulation Pump. Please read this manual thoroughly before installation and retain it for future reference.
The IBO BETA2 25-40/180 circulation pump is a high-efficiency, durable, and reliable pump designed to circulate water in central heating systems, solar installations, or hot water systems. This device features 11 speed settings, allowing for parameter adaptation to various operating conditions. An electronic processor controls the pump's operation. It is equipped with a single-phase motor with a power range of 5 to 22 W. Constructed from high-quality materials, the IBO BETA2 pump ensures optimal performance under all conditions and is resistant to high temperatures. It can operate in ambient temperatures from 0 °C to 40 °C, with the device surface reaching approximately 125 °C and pumped water temperatures up to 110 °C. The pump is designed for easy installation and intuitive use, featuring an electronic display that shows current energy consumption and operating status. Additionally, the pump operates quietly (43 dB) and offers significant energy efficiency, consuming between 1/10 and 1/3 of the energy compared to traditional pumps. The device has a 1 ½ inch diameter connection (180 mm distance between connections). It operates with a capacity of up to 50 liters per minute and can lift water up to a height of 4 meters. The Beta 2 25-40/180 pump includes a power cable and screw fittings.
2. تعليمات السلامة
Always observe the following safety precautions to prevent injury and damage to the pump or property:
- السلامة الكهربائية: Ensure the power supply matches the pump's specifications (230V). Disconnect power before any installation, maintenance, or repair work. All electrical connections must be performed by a qualified electrician and comply with local regulations.
- درجة حرارة الماء: The pump handles liquid temperatures from +2 °C to +110 °C. Ensure the system's operating temperature remains within this range.
- درجة الحرارة المحيطة: Operate the pump in ambient temperatures between 0 °C and 40 °C.
- ضغط: Do not exceed the maximum system pressure of 1 MPa.
- تثبيت: Install the pump in a dry, well-ventilated area, protected from frost and direct sunlight. Ensure proper ventilation to prevent overheating.
- التعامل: The pump is heavy (2.92 kg). Use appropriate lifting techniques or assistance during installation.
- الأطفال والأفراد غير المصرح لهم: أبقِ الأطفال والأشخاص غير المصرح لهم بعيدًا عن المضخة أثناء التشغيل والصيانة.
3. مكونات أكثرview
The IBO BETA2 25-40/180 circulation pump package typically includes the following items:
- IBO BETA2 25-40/180 Circulation Pump Unit
- كابل الطاقة
- Set of Screw Fittings (for pipe connection)
- دليل المستخدم (هذا المستند)

الشكل 3.1: IBO BETA2 25-40/180 Hot Water Circulation Pump. This image displays the IBO BETA2 25-40/180 hot water circulation pump. The pump is black, cylindrical in shape with two threaded pipe connections. An electronic display panel is visible on the front, showing 'ECO' and numerical readings, along with two green indicator lights and buttons labeled 'PP1', 'PP2', 'CP1', 'CP2'. A black power cable with a standard European plug is shown detached from the pump, indicating it's included for connection.
4. الإعداد والتثبيت
The IBO BETA2 25-40/180 pump is designed for easy installation. However, professional installation by a qualified technician is recommended to ensure proper functioning and compliance with all local codes and regulations.
4.1 فحوصات ما قبل التثبيت
- Verify that the installation site meets the ambient temperature requirements (0 °C to 40 °C).
- Ensure the power supply is 230V and adequately protected.
- Confirm that the pipe connections are clean and free of debris.
4.2 تركيب المضخة
- Choose a suitable location in the heating or hot water system where the pump can be easily accessed for maintenance.
- Ensure the pump is mounted horizontally with the motor shaft in a horizontal position to ensure proper lubrication and cooling.
- Use the provided screw fittings to connect the pump to the system piping. Ensure a tight, leak-free connection. The connection diameter is 1 ½ inches, with a distance of 180 mm between connections.
4.3 التوصيل الكهربائي
- Ensure the main power supply is switched off before making any electrical connections.
- Connect the provided power cable to the pump's electrical terminal block according to the wiring diagram (refer to the diagram on the pump or in the packaging if available).
- Connect the other end of the power cable to a grounded 230V power outlet.
- تأكد من أن جميع التوصيلات آمنة ومعزولة بشكل صحيح.
4.4 System Filling and Venting
- After installation, fill the heating or hot water system with water.
- Vent the system thoroughly to remove any trapped air. Air in the system can cause noise, reduce pump efficiency, and lead to damage.
5. تعليمات التشغيل
The IBO BETA2 25-40/180 pump features an electronic control system for intuitive operation.
5.1 بدء التشغيل الأولي
- After ensuring the system is filled and vented, switch on the main power supply to the pump.
- The electronic display will illuminate, showing the current operating status and energy consumption.
5.2 ضبط إعدادات السرعة
The pump offers 11 speed settings to adapt to various system requirements. Use the control buttons on the display panel (e.g., PP1, PP2, CP1, CP2, ECO) to cycle through the available modes and speeds. The display will indicate the selected setting and corresponding energy consumption.
- نمط الصدى: للتشغيل الموفر للطاقة.
- PP Modes: Proportional pressure modes, where pump head adjusts proportionally to flow rate.
- CP Modes: Constant pressure modes, maintaining a constant differential pressure.
Consult your heating system's requirements or a qualified technician to determine the optimal setting for your application.
5.3 عملية المراقبة
The electronic display provides real-time feedback on:
- Current energy consumption (in Watts)
- Selected operating mode/speed
- Any error codes (if applicable)
The pump operates quietly, with a sound pressure level of 43 dB.
6. الصيانة
Regular maintenance ensures the longevity and efficient operation of your IBO BETA2 25-40/180 pump.
6.1 General Checks (Monthly)
- Visually inspect the pump for any signs of leaks, corrosion, or damage.
- Listen for unusual noises during operation, which could indicate air in the system or mechanical issues.
- Check the electronic display for any error messages.
6.2 System Water Quality
Maintain good water quality in your heating system. Poor water quality can lead to scale buildup, corrosion, and reduced pump performance. Consider using appropriate system inhibitors if recommended for your heating system type.
6.3 التنظيف
Keep the exterior of the pump clean and free from dust and debris to ensure proper heat dissipation.
6.4 Professional Servicing (Annually)
It is recommended to have the pump and heating system inspected by a qualified technician annually to ensure optimal performance and identify any potential issues early.
7. استكشاف الأخطاء وإصلاحها
This section addresses common issues you might encounter with your IBO BETA2 25-40/180 pump. For complex problems, contact a qualified technician.
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| المضخة لا تعمل | لا يوجد مصدر للطاقة الصمامات المنفوخة / الكسارة المقطوعة انسداد المحرك | Check power connection and supply Check and replace fuse/reset breaker Disconnect power, check for obstructions in the impeller (professional service recommended) |
| تعمل المضخة ولكن لا يوجد دوران للمياه | الهواء في النظام الصمامات المغلقة انسداد المكره | Vent the system thoroughly Open all necessary valves in the system Disconnect power, check for obstructions (professional service recommended) |
| المضخة صاخبة | الهواء في النظام Cavitation (insufficient system pressure) تصاعد فضفاض | تنفيس عن النظام Check system pressure and increase if necessary Ensure pump is securely mounted |
| تسرب المضخة | اتصالات فضفاضة الأختام التالفة | Tighten pipe connections Contact a qualified technician for seal replacement |
| Electronic display shows error code | عطل داخلي محدد | Refer to the pump's specific error code list (if available in packaging) or contact technical support. |
8. المواصفات الفنية
| المعلمة | قيمة |
|---|---|
| نموذج | BETA2 25-40/180 |
| الشركة المصنعة | Röhtenbach |
| قوة المحرك | 5 - 22 واط |
| المجلدtage | 230 V (+6% / -10%) |
| مستوى السلامة | IP42 |
| فئة عزل المحرك | H |
| أقصى ارتفاع للرفع | 4 متر |
| الحد الأقصى لمعدل التدفق | 50 لتر في الدقيقة |
| الرطوبة النسبية | 95% |
| أقصى ضغط النظام | 1 ميجا باسكال |
| Pumped Liquid Temperature | من +2 درجة مئوية إلى +110 درجة مئوية |
| درجة الحرارة المحيطة | 0 درجة مئوية إلى 40 درجة مئوية |
| مستوى ضغط الصوت | 43 ديسيبل (أ) |
| قطر الاتصال | 1 ½ inches (180 mm between connections) |
| أبعاد المنتج (الطول × العرض × الارتفاع) | 21 × 18 × 11 سم |
| وزن العنصر | 2.92 كجم |
| مادة | الحديد الزهر |
| لون | أسود |
| نوع مصدر الطاقة | الكابلات الكهربائية |
9. معلومات الضمان
Specific warranty details for the IBO BETA2 25-40/180 pump are not provided in the available product information. Please refer to your purchase documentation or contact your retailer for warranty terms and conditions.
10. الدعم والاتصال
For technical assistance, spare parts, or service inquiries, please contact the retailer from whom you purchased the IBO BETA2 25-40/180 pump. Keep your purchase receipt and product model information readily available when contacting support.
الشركة المصنعة: Röhtenbach