The Generac 7668 120V Parallel Cable Kit is designed to enhance the power output of compatible Generac inverter generators. This kit allows you to connect two Generac iQ3500 or GP3000i inverter generators, effectively doubling their combined power capacity to meet higher electrical demands.
This cable kit provides a versatile power solution for various applications, including camping, tailgating, or as a backup power source for your home. It features both 30 Amp و 50 Amp 120V receptacles, offering flexibility for connecting a wide range of devices and appliances.

Image 1.1: The Generac 7668 Parallel Cable Kit, showing its main unit with 30A and 50A receptacles and the connecting cables.
2. معلومات السلامة
Always read and understand all safety warnings and instructions before operating this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.
- المخاطر الكهربائية: Ensure all connections are secure and dry before operating. Do not operate in wet conditions.
- Generator Safety: Refer to your generator's owner's manual for specific safety guidelines, including proper ventilation and carbon monoxide prevention.
- حماية من التحميل الزائد: The parallel kit includes circuit breakers (30A and 50A) to protect against overloads. Do not bypass or modify these.
- التأريض: Always ensure proper grounding of the generators and the parallel kit as per local electrical codes.
3. محتويات العبوة
تأكد من وجود جميع العناصر في الحزمة الخاصة بك:
- Generac 7668 Parallel Cable Kit Unit
- Integrated 2-foot connecting cables with custom plug ends
- دليل المستخدم (هذا المستند)
4. تعليمات الإعداد
Follow these steps for easy installation and connection of your parallel kit:
- Position Generators: Place your two compatible Generac iQ3500 or GP3000i inverter generators on a level, stable, and well-ventilated surface, ensuring they are at a safe distance from each other and any combustible materials.
- Ensure Generators are OFF: Before making any connections, ensure both generators are turned OFF and their engines have cooled down.
- Connect Parallel Cables: Locate the parallel ports on each generator. Insert the custom plug ends of the parallel cable kit into the corresponding ports on each generator. Ensure a firm and secure connection.
- التأريض (اختياري ولكن يُنصح به): If desired, connect a grounding wire from the parallel kit's grounding lug to a suitable earth ground. Refer to local electrical codes for proper grounding procedures.
- مستعد للعملية: Once the cables are securely connected, the parallel kit is ready for use.

الصورة 4.1: مثالample of Generac portable generators compatible with the parallel kit.
5. تعليمات التشغيل
After successful setup, follow these steps to operate your parallel generator system:
- Start Generators: Start both generators according to their individual operating instructions. Allow them to run for a few moments to stabilize.
- توصيل الأجهزة: Once both generators are running stably, you can connect your desired appliances or power cords to the 30 Amp أو 50 Amp 120V receptacles on the parallel cable kit.
- تحميل الشاشة: Pay attention to the total power draw to avoid overloading the combined capacity of your generators. The parallel kit allows for enhanced power capability, but exceeding the maximum combined wattage can trip circuit breakers or damage equipment.
- Powering a Home: For home backup power, connect the parallel kit to your transfer switch or appropriate inlet box. Consult a qualified electrician for proper installation and connection to your home's electrical system.
- اغلق: To shut down, first disconnect all loads from the parallel kit. Then, turn off both generators according to their respective manuals. Once generators are off and cooled, you may disconnect the parallel cables.

Image 5.1: The parallel kit enables sufficient power for home backup during outagإِسْ

Image 5.2: The parallel kit provides versatile power for outdoor activities like campأو التجمع قبل المباراة.
6. الصيانة
The Generac 7668 Parallel Cable Kit requires minimal maintenance. To ensure longevity and reliable performance:
- تنظيف: Keep the unit clean and free of dirt, dust, and debris. Use a dry cloth to wipe down the exterior. Do not use harsh chemicals or abrasive cleaners.
- تخزين: Store the parallel kit in a cool, dry place when not in use. Avoid extreme temperatures and direct sunlight.
- فحص الكابلات: Periodically inspect the cables and connectors for any signs of wear, damage, or fraying. Do not use the kit if any part is damaged.
- Receptacle Covers: Ensure the receptacle covers are properly closed when not in use to protect against moisture and debris.
7. استكشاف الأخطاء وإصلاحها
If you encounter issues with your Generac 7668 Parallel Cable Kit, refer to the following common problems and solutions:
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| No power output from parallel kit. |
|
|
| Kit feels hot during operation. | Overload or insufficient ventilation. | Reduce the electrical load. Ensure the kit and generators are in a well-ventilated area. If overheating persists, disconnect and allow to cool. |
| Cables do not fit into generator ports. | Incompatible generator models. | Ensure your generators are Generac iQ3500 or GP3000i inverter models. This kit is specifically designed for these models. |
If troubleshooting steps do not resolve the issue, contact Generac customer support.
8. المواصفات
| ميزة | التفاصيل |
|---|---|
| رقم الموديل | 7668 |
| التوافق | Generac iQ3500 and GP3000i Inverter Generators |
| المجلدtage | 120 فولت |
| الأوعية | 1 × 30 Amp 120V, 1 x 50 Amp 120 فولت |
| طول السلك | 2 أقدام (حوالي 0.6 أمتار) |
| أبعاد المنتج | 11 × 9.4 × 5.9 بوصة (27.9 × 23.9 × 15 سم) |
| وزن العنصر | 2 رطل (حوالي 0.91 كجم) |
| الشركة المصنعة | شركة Generac Power Systems، Inc |
9. الضمان والدعم
For warranty information and customer support, please refer to the official Generac website or contact Generac Power Systems, Inc. directly. Keep your purchase receipt for warranty claims.
Generac Customer Support:
- Visit the official Generac webالموقع للحصول على تفاصيل الاتصال وموارد الدعم.
- Refer to the documentation included with your Generac generators for additional support information.