Gre SCGPHP100

Gre SCGPHP100 Salt Electrolysis System

دليل المستخدم

1. انتهى المنتجview

The Gre SCGPHP100 is an advanced pool water treatment system that combines salt electrolysis for disinfection, an integrated pH controller, and a dosing pump. This system eliminates the need for traditional chemical chlorine, providing a more natural and comfortable swimming experience.

Gre SCGPHP100 Salt Electrolysis System with pH Controller and Dosing Pump

Figure 1: Complete Gre SCGPHP100 system including the main control unit, electrolysis cell, pH probe, and calibration solutions.

المميزات الرئيسية:

  • Integrated Disinfection: Salt electrolysis system produces natural chlorine from salt, eliminating the need for chemical chlorine.
  • pH Control: Built-in pH controller with an automatic dosing pump maintains optimal pH levels in your pool water.
  • قدرة عالية: Capable of producing 21 g/h of chlorine, suitable for pools up to 100 m³.
  • راحة معززة: Natural chlorine production reduces odors and eye irritation commonly associated with chemical chlorine.
  • Chemical-Free Handling: Minimizes the storage and handling of hazardous pool chemicals.

2. معلومات السلامة

Read all instructions carefully before installation and operation. Failure to follow these instructions may result in injury or damage to the equipment.

  • افصل الطاقة دائمًا قبل إجراء أي صيانة أو خدمة.
  • تأكد من التوصيل الكهربائي الأرضي بشكل صحيح.
  • أبقِ الوحدة بعيدًا عن أشعة الشمس المباشرة ودرجات الحرارة القصوى.
  • لا تقم بتشغيل النظام إذا كان أي جزء منه تالفًا.
  • حافظ على التهوية المناسبة حول الوحدة.
  • يحفظ بعيدًا عن متناول الأطفال.
  • Consult a qualified electrician or pool professional for installation if unsure.

3. التثبيت والإعداد

3.1. التفريغ والتفتيش

أزل جميع المكونات من العبوة بعناية. تأكد من وجود جميع الأجزاء وسلامتها. راجع قائمة المحتويات للاطلاع على الجرد الكامل.

3.2. وضع النظام

Install the main control unit in a dry, well-ventilated area, protected from direct weather exposure. The unit should be mounted vertically on a wall or sturdy surface near the pool's filtration system.

أمام view of Gre SCGPHP100 main control unit

Figure 2: Main control unit with pH display and control buttons.

3.3. توصيلات السباكة

  1. Electrolysis Cell: Install the electrolysis cell (salt cell) in the return line of your pool's filtration system, after the filter and heater (if applicable). Ensure the flow direction arrow on the cell matches the water flow.
  2. Gre SCGPHP100 electrolysis cell

    Figure 3: The transparent electrolysis cell where chlorine is generated.

  3. مسبار الرقم الهيدروجيني: Install the pH probe in a dedicated probe holder or a suitable location in the plumbing line where water flow is consistent.
  4. Gre SCGPHP100 pH probe

    Figure 4: The pH probe, used to measure the pool water's pH level.

  5. مضخة الجرعات: Connect the suction tube of the dosing pump to a container of pH-reducing liquid (e.g., liquid acid). Connect the injection tube to an injection point in the pool's return line, typically after the electrolysis cell.
  6. Close-up of the dosing pump on the Gre SCGPHP100 unit

    Figure 5: Detail of the peristaltic dosing pump for pH correction.

3.4. التوصيلات الكهربائية

Connect the main control unit to a dedicated, grounded electrical outlet. Ensure all connections are secure and comply with local electrical codes. Connect the electrolysis cell and pH probe cables to their respective ports on the main unit.

3.5. Initial Pool Water Preparation

  • أضف الملح: Add pool-grade salt to your pool water to achieve a concentration of 4 g/l (grams per liter). Circulate the water until the salt is fully dissolved.
  • Balance Water Chemistry: Before starting the system, ensure your pool's alkalinity and calcium hardness are within recommended ranges.

4. تعليمات التشغيل

4.1. تشغيل

Once all connections are made and the pool water is prepared, switch on the power to the unit. The display will illuminate, showing the current pH reading.

4.2. pH Probe Calibration

For accurate pH readings, calibrate the pH probe regularly (e.g., monthly or after long periods of inactivity). Use the provided calibration solutions (pH 7.0 and pH 4.0).

pH calibration solutions for Gre SCGPHP100

Figure 6: pH 7.0 and pH 4.0 calibration solutions.

  1. Rinse the pH probe with distilled water.
  2. Immerse the probe in the pH 7.0 solution. Press the "CAL" button and follow the on-screen prompts until calibration is complete.
  3. Rinse the probe again.
  4. Immerse the probe in the pH 4.0 solution. Press the "CAL" button and follow the on-screen prompts until calibration is complete.
  5. Return the probe to its holder in the plumbing line.

4.3. Setting pH Target

Use the "SET" button to adjust the desired pH target level (typically between 7.2 and 7.6 for pools). The system will automatically dose pH-reducing liquid to maintain this level.

4.4. ضبط إنتاج الكلور

The unit features a "Power selector" to adjust the chlorine production level (e.g., 0%, 50%, 75%, 100%). Start with a moderate setting and adjust based on pool usage and chlorine demand. The "SALT" indicator will illuminate if salt levels are too low.

5. الصيانة

5.1. Electrolysis Cell Cleaning

The electrolysis cell may accumulate scale deposits over time, especially in hard water areas. Inspect the cell regularly (e.g., monthly) and clean as needed.

بزاوية view of the Gre SCGPHP100 electrolysis cell

الشكل 7: بزاوية view of the electrolysis cell, showing the internal plates.

  1. Turn off the system and close all valves to isolate the cell.
  2. Remove the cell from the plumbing.
  3. Soak the cell in a diluted acid solution (e.g., 1 part muriatic acid to 4 parts water) for no more than 15 minutes, or until deposits dissolve. ارتدِ معدات السلامة المناسبة.
  4. اشطف جيداً بالماء العذب قبل إعادة التركيب.

5.2. pH Probe Maintenance

  • Keep the pH probe tip moist when not in use, preferably in a storage solution or pH 7.0 buffer.
  • Clean the probe tip gently with a soft brush if deposits are visible.
  • Recalibrate the probe regularly as described in Section 4.2.

5.3. Salt Level Monitoring

Regularly check your pool's salt concentration using a salt test kit. Maintain a level of 4 g/l for optimal system performance. Add salt as needed.

6. استكشاف الأخطاء وإصلاحها

مشكلةالسبب المحتملحل
No Chlorine ProductionLow salt level; Dirty electrolysis cell; Low water flow; System off.Check salt level and add salt; Clean electrolysis cell; Ensure pump is running and filter is clean; Turn system on.
Incorrect pH ReadingpH probe needs calibration; Dirty pH probe; pH probe faulty.Calibrate pH probe (Section 4.2); Clean pH probe; Replace pH probe.
pH Not AdjustingDosing pump not working; Empty pH-reducing liquid container; Clogged injection line.Check dosing pump power/operation; Refill liquid container; Clear injection line.
"SALT" Indicator Onمستوى الملح منخفض جدًا.Add pool-grade salt to achieve 4 g/l concentration.

7. المواصفات

ميزةالتفاصيل
رقم الموديلإس سي جي بي إتش بي 100
ماركةجري
Chlorine Production Capacity21 جرام/ساعة
حجم المسبح الموصى بهحتى 100 متر مكعب
Required Salt Concentration4 جرام/لتر
أبعاد المنتج (الطول × العرض × الارتفاع)19.5 × 13 × 26 سم
وزن المنتج1.3 كيلوغرام
الشركة المصنعةاختبار GRE

8. الضمان والدعم

For warranty information and technical support, please refer to the official Gre webالموقع أو اتصل بالوكيل المعتمد لديك. احتفظ بإيصال الشراء كإثبات للشراء.

Note: Information regarding spare parts availability is not provided in the product data.

المستندات ذات الصلة - إس سي جي بي إتش بي 100

قبلview نظام الملح المتصل من GRE - دليل التعليمات
دليل تعليمات شامل لنظام GRE CONNECTED الملحي، يتضمن تفاصيل التركيب والتشغيل والصيانة واستكشاف الأعطال والمواصفات الفنية لأجهزة تعقيم مياه المسابح بالملح. يشمل إرشادات السلامة ومعلومات الضمان.
قبلview دليل تركيب وصيانة حمامات السباحة Gre
دليل شامل من Gre لتركيب واستخدام حوض السباحة المركب بأمان، يغطي موديلات KPCO41 وKPCOV52 وKPCOV80. يتضمن احتياطات السلامة، ومعلومات الضمان، وتعليمات التركيب خطوة بخطوة.
قبلview حوض سباحة خشبي GRE ORANGE 800007: دليل التعليمات ودليل التجميع
دليل التعليمات الرسمي لحوض السباحة الخشبي الأرضي GRE ORANGE 800007. يوفر خطوات التركيب التفصيلية، وإرشادات التركيب، ونصائح الصيانة، واحتياطات السلامة، ومعلومات الضمان من GRE.
قبلview فلتر خرطوشة Gre CFAQ35 مع Aqualoon: دليل التعليمات
دليل تعليمات شامل لفلتر خرطوشة Gre CFAQ35 مع Aqualoon. يغطي السلامة والتركيب والتشغيل والصيانة والضمان لتنقية مياه المسبح على النحو الأمثل.
قبلview شهادة ضمان ومعلومات ضمان حمام السباحة من GRE
شهادة الضمان الرسمية ومعلومات الضمان لحمامات السباحة من GRE، تتضمن تفاصيل الشروط والأحكام والاستثناءات وخدمة ما بعد البيع. تغطي الضمانات القانونية والتجارية.
قبلview دليل الإعداد السريع لمصابيح حمام السباحة GRE PLED2 المغناطيسية LED تحت الماء
تعليمات تركيب موجزة ودليل مستخدم لأضواء حمام السباحة المغناطيسية GRE PLED2 LED تحت الماء، المصممة لحمامات السباحة فوق الأرض. يتضمن معلومات عن التركيب والتشغيل والضمان.