Mahr AMR-12 2086960

Mahr AMR-12 Magnification Kit 2086960 Instruction Manual

Model: AMR-12 2086960

1. المقدمة

يوفر هذا الدليل معلومات أساسية للاستخدام الآمن والفعال لـ Mahr AMR-12 Magnification Kit, model 2086960. This kit is specifically designed for the calibration of pneumatic display units, ensuring accurate measurements in industrial and scientific applications. Please read this manual thoroughly before operating the device and retain it for future reference.

Mahr AMR-12 Magnification Kit 2086960

Figure 1: Mahr AMR-12 Magnification Kit, model 2086960, showing its primary components.

2. معلومات السلامة

To ensure safe operation and prevent damage to the device or injury to personnel, observe the following safety precautions:

  • Always handle the magnification kit with care. It is a precision instrument.
  • Do not expose the kit to extreme temperatures, humidity, or corrosive environments.
  • Avoid dropping or subjecting the kit to strong impacts.
  • Only use the kit for its intended purpose: the calibration of pneumatic display units.
  • Keep the kit clean and free from dust and debris.
  • Do not attempt to disassemble or modify the kit. Refer servicing to qualified personnel.

3. محتويات العبوة

The Mahr AMR-12 Magnification Kit, model 2086960, includes the following components:

  • Magnification Kit components (as specified by Mahr)

Upon unpacking, inspect all items for any signs of damage. If any components are missing or damaged, contact your supplier immediately.

4. الإعداد

Follow these steps to set up your Mahr AMR-12 Magnification Kit:

  1. أفرغ: قم بإزالة جميع المكونات بعناية من العبوة.
  2. فحص: Visually inspect all parts for any damage that may have occurred during shipping.
  3. بيئة: Ensure the working environment is clean, stable, and free from vibrations. Maintain a consistent temperature and humidity as recommended for precision instruments.
  4. حَشد: Assemble the magnification kit components according to the specific instructions provided with the kit's internal documentation (if applicable). Ensure all connections are secure.
  5. تحضير: Prepare the pneumatic display unit that requires calibration according to its own instruction manual.

5. تعليمات التشغيل

The Mahr AMR-12 Magnification Kit is designed for precise calibration. Follow these general operating procedures:

  1. اتصال: Connect the magnification kit to the pneumatic display unit as per the calibration procedure. Ensure a secure and leak-free connection.
  2. إجراء المعايرة: Follow the specific calibration steps outlined in the documentation for the pneumatic display unit and the magnification kit. This typically involves applying known pressure values and observing the display unit's readings through the magnification kit.
  3. ملاحظة: Use the magnification kit to accurately read the fine scales or indicators on the pneumatic display unit. The kit enhances visibility for precise measurement.
  4. تسجيل البيانات: Record all calibration data meticulously.
  5. الإنقطاع: After calibration, carefully disconnect the magnification kit from the pneumatic display unit.

Note: Specific calibration procedures may vary depending on the pneumatic display unit being calibrated. Always refer to the primary instrument's manual for detailed steps.

6. الصيانة

Proper maintenance ensures the longevity and accuracy of your Mahr AMR-12 Magnification Kit:

  • تنظيف: Use a soft, lint-free cloth to clean the surfaces of the kit. For optical components, use specialized lens cleaning solutions and cloths to avoid scratching.
  • تخزين: Store the kit in its original packaging or a protective case when not in use. Keep it in a dry, dust-free environment with stable temperature.
  • تقتيش: Periodically inspect the kit for any signs of wear, damage, or loose components.
  • معايرة: While the kit itself is a calibration aid, ensure it is handled with care to maintain its optical and mechanical integrity.

7. استكشاف الأخطاء وإصلاحها

This section addresses common issues you might encounter with the Mahr AMR-12 Magnification Kit:

مشكلة السبب المحتمل حل
Unclear image/view through magnification kit Dust or smudges on optical components; improper focus. Clean optical surfaces with appropriate cleaning materials. Adjust the focus mechanism if available.
Kit components feel loose Connections not fully tightened. Gently tighten any adjustable connections. Do not overtighten.
Inaccurate calibration results Improper setup; environmental factors; faulty pneumatic unit. Review setup steps. Ensure stable environment. Verify the pneumatic display unit's condition. The magnification kit itself does not introduce inaccuracy if properly used.

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, contact Mahr customer support.

8. المواصفات

ميزة التفاصيل
ماركة مهر
رقم الموديل 2086960
الشركة المصنعة شركة ماهر المحدودة
أبعاد المنتج (الطول × العرض × الارتفاع) 50 × 21.6 × 19.7 سم
وزن العنصر 1 كيلوغرام
العناصر الموجودة في العبوة 1
دقة القياس +/-0.5%
وشملت المكونات Magnification Kit
البطاريات المطلوبة لا
ASIN B07Z9CSWDK

9. الضمان والدعم

For information regarding warranty coverage, technical support, or spare parts availability for your Mahr AMR-12 Magnification Kit, please contact Mahr GmbH directly or your authorized Mahr distributor. Keep your purchase receipt and model number (2086960) handy when contacting support.

ملحوظة: المعلومات المتعلقة بتوفر قطع الغيار غير متوفرة حاليًا.

المستندات ذات الصلة - AMR-12 2086960

قبلview Mahr Millimar N 1700 Modular Connection System - Quick Start Guide
This quick start guide provides essential information for the Mahr Millimar N 1700 modular connection system. Learn about permitted use, module assembly, data communication, firmware updates, and compliance. Ideal for users in production, quality control, and workshops.
قبلview Mahr Pocket Surf® IV Portable Surface Roughness Gage - Features and Technical Data
Discover the Mahr Pocket Surf® IV, a compact and economical portable instrument for precise surface roughness measurements. This document outlines its key features, technical specifications, available probes, and accessories for various industrial applications.
قبلview Mahr Engineered Solutions: Precision Dimensional Metrology Devices
Explore Mahr's range of engineered solutions for precision dimensional metrology, including air gaging, taper measurement, gear tooth alignment, and universal measuring units for various industrial applications.
قبلview Mahr MarCator & Millimess Bedienungsanleitung: Digitale Messuhren
Umfassende Bedienungsanleitung für Mahr MarCator und Millimess digitale Messuhren. Erfahren Sie mehr über Funktionen wie Toleranzeinstellung, Datenübertragung und Menüführung.
قبلview Mahr Micromar 844 EWR / 844 EWR i Digital 3-Point Bore Gage - Operating Instructions
Comprehensive operating instructions for the Mahr Micromar 844 EWR and 844 EWR i digital 3-point bore gages. Covers menu functions, parameter settings, MarCom software integration, data communication, display messages, and compliance information.
قبلview Mahr MarCator Dial Indicators Series A and N - Technical Specifications
Detailed technical specifications, features, and accessory options for Mahr Federal Series A (inch) and Series N (metric) dial indicators, including measuring ranges, graduation values, accuracy, and mounting hardware.