Prity FGW15

Prity FGW15 Wood-Burning Stove with Oven and Back Boiler

دليل المستخدم

1. المقدمة

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Prity FGW15 wood-burning stove with oven and back boiler. This appliance is designed to provide both room heating and hot water for central heating systems, while also offering a functional oven for cooking. Please read this manual thoroughly before using the appliance and retain it for future reference.

The Prity FGW15 stove complies with European standards EN 13240:2001 and EN 13299:2001, ensuring its quality and safety for domestic use.

2. معلومات السلامة

التثبيت المهني المطلوب: This appliance requires professional installation by a qualified technician to ensure safe and correct operation, as well as compliance with local building codes and regulations. Improper installation can lead to fire hazards, carbon monoxide poisoning, and other serious risks.

2.1 تحذيرات السلامة العامة

2.2 Minimum Clearances to Combustible Materials

Maintain the following minimum distances from combustible materials to prevent fire hazards:

These distances are critical for safety. Consult your installer for specific requirements based on your installation.

2.3 Permissible Fuel

استخدم فقط dry firewood as fuel. The wood moisture content should be 16 ± 4% according to EN 13240:2006, EN 13229:2006, EN 12815:2006 Annex B, Table B.1. Do not burn treated wood, plastics, coal, or any other materials not specified for wood-burning stoves, as this can damage the appliance, create hazardous emissions, and void your warranty.

3. مكونات المنتج

The Prity FGW15 is a versatile appliance combining a wood-burning firebox, an oven, and a back boiler for central heating. Key components include:

أمام view of Prity FGW15 wood-burning stove with oven and back boiler, showing the firebox, oven, and ash drawer.

الشكل 3.1: الجبهة view of the Prity FGW15 stove, highlighting the firebox, oven, and ash drawer.

مؤخرة view of Prity FGW15 wood-burning stove, showing the back boiler connections and flue outlet.

الشكل 3.2: خلفي view of the Prity FGW15 stove, illustrating the cold and hot water connections for the back boiler and the flue pipe outlet.

4. المواصفات الفنية

Below are the detailed technical specifications for the Prity FGW15 wood-burning stove:

Prity FGW15 wood-burning stove dimensions: 93 cm height, 57 cm width, 53 cm depth.

Figure 4.1: Key dimensions of the Prity FGW15 stove.

ميزةمواصفة
نموذجFGW15
ماركةشبح
أبعاد المنتج (العمق × العرض × الارتفاع)53 × 57 × 93 سم
وزن136 كجم
مادةالحديد الزهر
Nominal Room Heating Power5 كيلو واط
Nominal Water Heating Power15 كيلو واط
Total Nominal Heat Output19.8 كيلو واط
سعة الغلاية15 لتر
Cold Water Inlet / Hot Water Outlet2.5 سم (1 بوصة)
قطر أنبوب الدخان130 ملم
كفاءة76.5%
Approximate Heating Surface Area114 m² (for room heating)
أبعاد صندوق النار (العرض × العمق × الارتفاع)465 × 240 × 430 ملم
Oven Dimensions (W x D x H)380 × 400 × 200 ملم
Maximum Working Pressure (Water)1.25 بار
درجة حرارة غاز المداخن192 درجة مئوية
CO in Flue Gas1031.3 mg/Nm³ (0.0985 %)
Dust Content26.4 مجم/نيوتن متر مكعب
NOx Content102.7 مجم/نيوتن متر مكعب
CxHy Content43.8 مجم/نيوتن متر مكعب

5. متطلبات التثبيت

Installation of the Prity FGW15 stove must be carried out by a certified professional in accordance with all national and local building and fire safety regulations. This includes proper chimney connection, flue pipe installation, and integration with your central heating system.

5.1 Chimney and Flue Pipe

5.2 Water Connections for Back Boiler

The back boiler requires connection to a closed or open central heating system. The cold water inlet and hot water outlet connections are 2.5 cm (1 inch). A qualified plumber must perform these connections, ensuring proper pressure relief valves, expansion tanks, and circulation pumps are installed according to system requirements and local codes.

5.3 Positioning and Clearances

Refer to Section 2.2 for minimum clearances to combustible materials. The stove must be placed on a non-combustible hearth extending beyond the appliance as required by local regulations.

6. تعليمات التشغيل

Before operating, ensure all installation checks are complete and the central heating system (if connected) is filled and vented.

6.1 Starting the Fire

  1. Open both the front air supply damper and the smoke damper fully.
  2. Place a small amount of kindling and firelighters on the cast iron grate in the firebox.
  3. Light the kindling. Once it is burning well, add small pieces of dry firewood.
  4. Close the firebox door securely.
  5. Allow the fire to establish fully before adding larger logs.

6.2 Air Control and Flame Intensity

The stove is equipped with two manual dampإرس:

Adjust both dampers to achieve a steady, efficient burn. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or poor draft.

6.3 استخدام الفرن

The oven utilizes heat from the firebox below. The oven temperature will vary depending on the intensity of the fire. Monitor the oven temperature gauge and adjust the fire's intensity as needed for cooking. Preheat the oven thoroughly before placing food inside.

7. الصيانة

Regular maintenance is crucial for the safe and efficient operation of your Prity FGW15 stove.

7.1 إزالة الرماد

Remove ash from the ash drawer regularly, ideally before each use or when the ash bed becomes thick. Allow the stove to cool completely before removing ash. Dispose of ash in a metal container with a tight-fitting lid, away from combustible materials.

7.2 تنظيف الزجاج

Clean the ceramic glass on the firebox and oven doors as needed. Use a specialized stove glass cleaner or a damp cloth dipped in fine ash (when cold) to remove soot. Avoid abrasive cleaners or tools that could scratch the glass.

7.3 Flue Pipe and Chimney Cleaning

The flue pipe and chimney must be inspected and cleaned by a qualified chimney sweep at least once a year, or more frequently if heavy use or creosote buildup is observed. Blockages can lead to dangerous chimney fires and carbon monoxide accumulation.

7.4 التفتيش العام

Periodically check all seals, hinges, and dampers for wear or damage. Ensure water connections for the back boiler are free from leaks. Replace any worn parts promptly.

8. استكشاف الأخطاء وإصلاحها

This section addresses common issues you might encounter with your Prity FGW15 stove.

مشكلةالسبب المحتملحل
الدخان يدخل الغرفةBlocked chimney/flue, insufficient draft, door opened too quickly, wet fuel.Check chimney/flue for blockages. Ensure dampers are open. Use dry fuel. Open door slowly.
انخفاض إنتاج الحرارةInsufficient air supply, wet fuel, small fire, poor insulation.الهواء الطلق دampers. Use dry, seasoned wood. Build a larger fire. Check room insulation.
النار تحترق بسرعة كبيرةExcessive air supply, door not sealed properly.إغلاق الهواء دampers partially. Check door seals and replace if necessary.
الزجاج يتحول إلى اللون الأسود بسرعةWet fuel, insufficient air for combustion, low burning temperature.Use dry fuel. Increase air supply. Ensure fire burns hot enough.
Central heating not heating effectivelyLow fire intensity, air in system, pump malfunction, system blockage.Increase fire intensity. Bleed radiators. Check circulation pump. Consult a plumber.

If you encounter persistent problems that cannot be resolved using this guide, contact a qualified technician or your seller for assistance.

9. الامتثال والشهادات

The Prity FGW15 wood-burning stove is manufactured and tested to meet stringent European standards.

9.1 European Standards

This appliance complies with:

9.2 ملصق كفاءة الطاقة

The Prity FGW15 has an energy efficiency rating of A. This label provides information on the energy performance of the appliance.

Energy efficiency label for Prity FGW15 stove, showing an A rating and heat outputs.

Figure 9.1: Energy Efficiency Label for Prity FGW15.

9.3 إعلان الأداء

A Declaration of Performance (DoP) is available, confirming the essential characteristics and performance of the product in accordance with Regulation (EU) No 305/2011.

Declaration of Performance document for Prity FGW15, detailing compliance and technical data.

Figure 9.2: English Declaration of Performance for Prity FGW15.

10. الضمان والدعم

For warranty information, please refer to the terms and conditions provided at the point of purchase or contact your seller directly. In case of technical issues, questions, or the need for spare parts, please contact the retailer from whom you purchased the Prity FGW15 stove. Ensure you have your purchase details and the product model number (FGW15) available when contacting support.

المستندات ذات الصلة - FGW15

قبلview غلايات بريتي: الوصف الفني ودليل التركيب والتشغيل
دليل شامل لمراجل بريتي السكنية، يغطي المواصفات الفنية وإجراءات التثبيت وتعليمات التشغيل والصيانة واستكشاف الأخطاء وإصلاحها لموديلات الوقود الصلب والحبيبات.