This manual provides essential information for the installation, operation, and maintenance of your Lunos e² decentralized ventilation system. Please read this manual thoroughly before installation and operation to ensure proper function and safety. Keep this manual for future reference.

The Lunos e² system is a highly efficient, decentralized ventilation unit with heat recovery, designed for room-by-room ventilation. It operates on a reversible airflow principle using a ceramic regenerator, ensuring low energy consumption and quiet operation.

مكونات المنتج

انفجرت view of Lunos e² ventilation unit components and accessories

الشكل 1: انفجرت view of the Lunos e² decentralized ventilation units and accompanying accessories. This image shows two complete ventilation units, two round ducts, a universal control unit, a power supply, and a wall switch. Each ventilation unit consists of an outer grille, a fan, a ceramic heat exchanger, and an inner panel with a filter.

The Lunos e² system includes:

الإعداد والتثبيت

Installation should be performed by a qualified professional. Ensure all local building codes and regulations are followed.

فحوصات ما قبل التثبيت:

خطوات التثبيت:

  1. Drill a 162 mm diameter hole through the wall at the desired location, ensuring a slight downward slope to the outside for drainage.
  2. Insert the round duct (DN160 mm) into the drilled hole. Cut the duct to the appropriate length for the wall thickness.
  3. Install the Lunos e² ventilation unit into the duct. Ensure the ceramic heat exchanger and fan are correctly oriented.
  4. Mount the exterior grille (1-WE 180) on the outside of the wall, securing it with screws.
  5. Mount the interior panel with filter (9/IBE) on the inside of the wall.
  6. Connect the ventilation units to the 5/UNI-FT universal control unit.
  7. Connect the 5/NT18 power supply to the universal control unit and to the main power.
  8. Install the 5/W2U switch in a convenient location and connect it to the universal control unit.

تعليمات التشغيل

The Lunos e² system is designed for continuous operation to maintain optimal indoor air quality and heat recovery.

التشغيل الأساسي:

أوضاع التشغيل:

The Lunos e² system typically offers multiple fan speed settings to adjust ventilation rates:

The system also features humidity recovery, typically around 20-30%, to prevent excessive drying of indoor air during colder months.

صيانة

Regular maintenance ensures optimal performance and longevity of your Lunos e² ventilation system.

استبدال/تنظيف الفلتر:

The G3 filter should be checked regularly and replaced or cleaned as needed, typically every 3-6 months depending on air quality.

  1. Turn off the ventilation system at the main switch.
  2. Carefully remove the interior panel.
  3. Remove the G3 filter.
  4. Clean the filter by vacuuming or gently washing with warm water (if washable type). Allow to dry completely before reinstallation. Replace if heavily soiled or damaged.
  5. Reinsert the clean/new filter and reattach the interior panel.
  6. قم بتشغيل النظام مرة أخرى.

Ceramic Heat Exchanger Cleaning:

The ceramic heat exchanger should be cleaned annually or if performance degrades.

  1. Turn off the ventilation system.
  2. Remove the interior panel and filter.
  3. Carefully pull out the ceramic heat exchanger unit.
  4. Clean the ceramic core under running water. Do not use harsh detergents. Allow to dry completely.
  5. Reinsert the dry ceramic heat exchanger, ensuring correct orientation.
  6. Reinstall the filter and interior panel.
  7. قم بتشغيل النظام مرة أخرى.

Exterior Grille Cleaning:

Periodically inspect and clean the exterior grille to ensure unobstructed airflow.

استكشاف الأخطاء وإصلاحها

If you experience issues with your Lunos e² system, consult the following table before contacting support.

مشكلةالسبب المحتملحل
System not operatingNo power supply; switch is OFF.Check power connection; ensure switch is ON. Verify power supply (5/NT18) is functioning.
Reduced airflow or efficiencyClogged filter; dirty ceramic heat exchanger; obstructed exterior grille.Clean or replace filter; clean ceramic heat exchanger; clear any obstructions from the exterior grille.
ضوضاء غير عاديةانسداد المروحة؛ مكونات مفكوكة.Turn off system and inspect fan for obstructions. Ensure all components are securely installed. If noise persists, contact support.
Condensation around unitImproper installation (e.g., no downward slope); extreme temperature difference.Ensure proper installation with slight downward slope. If problem persists, consult a professional.

تحديد

Detailed technical specifications for the Lunos e² decentralized ventilation system.

Lunos e² Energy Label

الشكل 2: Energy label for the Lunos e² ventilation system, indicating an A+ energy efficiency rating, 40 dB sound level, and a maximum airflow of 38 m³/h.

Lunos e² Product Data Sheet

الشكل 3: Product data sheet for the Lunos e² ventilation system, detailing specifications such as supplier, model identification, specific energy consumption, type of heat recovery, thermal efficiency, maximum flow rate, power input, sound pressure level, and annual energy consumption.

المعلمةقيمة
نموذجLunos e²
كفاءة استعادة الحرارة90.6%
Airflow Volume (m³/h)18 / 31 / 38
Power Consumption per unit (W)1.4 / 2.8 / 3.3
Rated Power (W/m³/h)0.09
Network Voltage12 فولت تيار مستمر
استعادة الرطوبةApprox. 20-30%
مستوى ضغط الصوت (ديسيبل)16.5 / 19.5 / 26
Normal Sound Level (DN,W, open)42 ديسيبل
طول الوحدة243 ملم
الحد الأدنى لسمك الجدار300 ملم
قطر الحفرة162 ملم

الضمان والدعم

For warranty information, please refer to the documentation provided with your purchase or contact Lunos directly. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or further assistance, please contact Lunos customer service. Contact details can typically be found on the manufacturer's official webالموقع أو على فاتورة الشراء الخاصة بك.

الشركة المصنعة: Lunos

Webموقع: www.lunos.de

المستندات ذات الصلة - localization_B07MQ62LLD

قبلview دليل تركيب نظام التهوية اللامركزي LUNOS Nexxt
دليل تركيب شامل لنظام التهوية اللامركزي LUNOS Nexxt مع استعادة الحرارة، يغطي المواصفات الفنية والتركيب والتوصيلات الكهربائية وإعدادات مفتاح DIP واستبدال المرشح والصيانة.
قبلview دليل تركيب نظام التهوية اللامركزية من سلسلة LUNOS e²
دليل تركيب نظام التهوية اللامركزي من سلسلة LUNOS e² مع استعادة الحرارة. يتضمن المواصفات الفنية، ومخططات التوصيل الكهربائي، وإرشادات التركيب.
قبلview نظام التهوية اللامركزي من سلسلة LUNOS e² مع استرداد الحرارة - دليل التركيب
دليل تركيب شامل لنظام التهوية اللامركزي e² من سلسلة LUNOS مع خاصية استعادة الحرارة. يغطي تفاصيل المنتج، والمواصفات الفنية، والتوصيلات الكهربائية، وإرشادات التركيب، والصيانة لطرازات e² وe²kurz وe²60 وe²60kurz.
قبلview دليل تثبيت التحكم العالمي LUNOS 5/UNI-FT & 5/UNI-RF
دليل التثبيت لنظام التحكم العالمي LUNOS 5/UNI-FT و 5/UNI-RF، والذي يشرح بالتفصيل الميزات والمواصفات الفنية والتوصيلات الكهربائية وإعدادات مفتاح الترميز وأوضاع التشغيل لأنظمة التهوية.
قبلview LUNOS Universal Controller 5/UNI-FT Settings Guide
Comprehensive guide to the LUNOS Universal Controller (Typ: 5/UNI-FT, No.:40269), covering features, technical specifications, electrical connections, dial settings, and handling instructions for optimal ventilation system management.
قبلview دليل تكثيف التهوية في نظام LUNOS: الأسباب والحلول
دليل شامل من شركة لونوس حول فهم ومنع وتقليل التكثيف على الشاشات الداخلية لوحدات التهوية المنزلية. تعرف على أسباب مثل الرطوبة المتبقية وكيفية الحفاظ على مستوى الرطوبة الأمثل داخل المنزل.