This manual provides essential information for the safe and efficient operation of your Nedis UPSD2000VBK Uninterruptible Power Supply. Please read these instructions carefully before installation and use, and retain them for future reference. This UPS is designed to provide backup power and protect your electronic devices from power outages, surges, and fluctuations.
تعليمات السلامة
- للاستخدام الداخلي فقط: This UPS is designed for indoor use in a controlled environment. Do not expose it to rain, snow, or direct sunlight.
- تهوية: Ensure adequate ventilation around the UPS. Do not block ventilation openings. Maintain at least 20 cm of clearance from walls or other obstructions.
- مصدر الطاقة: Connect the UPS to a properly grounded AC power outlet. Do not remove the grounding prong.
- التحميل الزائد: Do not overload the UPS. The total power consumption of connected equipment must not exceed the UPS's rated capacity (1200 W).
- سلامة البطارية: The UPS contains internal batteries. Do not attempt to open the UPS casing or service the batteries yourself. Refer all servicing to qualified personnel.
- التلامس السائل: Avoid placing liquids on or near the UPS. In case of accidental spillage, immediately disconnect the UPS from the power source and contact support.
- قطع الاتصال في حالات الطوارئ: Ensure the AC power outlet for the UPS is easily accessible for quick disconnection in an emergency.
المنتج انتهىview
The Nedis UPSD2000VBK is a compact and efficient uninterruptible power supply. Familiarize yourself with its components before proceeding with installation.

الشكل 1: الامام والجانب view of the Nedis UPSD2000VBK. This image displays the main power button and the vertical strip of LED indicators on the front panel, along with ventilation grilles on the side.

الشكل 2: مؤخرة view of the Nedis UPSD2000VBK. This image highlights the four power outlets, the USB communication port, and the RJ45 network protection ports (IN/OUT), along with the main power input and cooling fan.
المكونات الرئيسية:
- اللوحة الأمامية: Power button, LED status indicators (AC mode, battery mode, fault, battery level).
- اللوحة الخلفية: AC input, 4 x Schuko output sockets, USB communication port, RJ45 network protection ports (IN/OUT).
- داخلي: Sealed lead-acid batteries, inverter, charger, control circuitry.
يثبت
1. فك التعبئة
- قم بإخراج جهاز UPS من عبوته بعناية.
- Inspect the unit for any shipping damage. If damage is found, do not operate the unit and contact your dealer.
2. تحديد مستوى
- Place the UPS on a flat, stable surface in a well-ventilated area.
- Avoid locations with excessive dust, humidity, or extreme temperatures.
- تأكد من أن درجة الحرارة المحيطة تتراوح بين 0 درجة مئوية و40 درجة مئوية (32 درجة فهرنهايت و104 درجة فهرنهايت).
3. توصيل الأجهزة
- قم بتوصيل سلك الطاقة الخاص بجهاز UPS بمأخذ حائط مؤرض.
- Plug your computer, monitor, and other critical devices into the output sockets on the rear of the UPS. Ensure the total load does not exceed 1200 W.
- خياري: Connect a USB cable from the UPS to your computer for monitoring software functionality (software not included, typically available from manufacturer's webموقع).
- خياري: Connect network cables through the RJ45 IN/OUT ports to protect your network devices from surges.
4. الشحن الأولي
For optimal performance, charge the UPS for at least 8 hours before initial use. Leave the UPS connected to the AC power outlet with no load connected during this period.
التشغيل
1. تشغيل/إيقاف
- لتشغيل: اضغط مع الاستمرار على زر الطاقة الموجود على اللوحة الأمامية لمدة 3 ثوانٍ تقريبًا حتى تسمع صوت تنبيه وتضيء المؤشرات.
- لإيقاف التشغيل: Press and hold the power button for approximately 3 seconds until you hear a beep and the indicators turn off.
2. فهم المؤشرات والإنذارات
The front panel features LED indicators and an audible alarm to communicate the UPS status:
- AC Mode (Green LED): Solid green indicates the UPS is operating on utility power and charging the battery.
- Battery Mode (Yellow LED): Flashing yellow indicates the UPS is operating on battery power. An audible alarm will sound periodically.
- Fault (Red LED): Solid red indicates a fault condition. Refer to the troubleshooting section. An audible alarm may sound continuously.
- مؤشرات مستوى البطارية: A series of LEDs typically indicates the remaining battery capacity.
3. Battery Mode Operation
When utility power fails, the UPS automatically switches to battery mode, providing power to connected devices. The duration of battery backup depends on the load connected. During battery mode, save your work and shut down your equipment properly to prevent data loss.
صيانة
1. العناية بالبطارية
- To maximize battery life, keep the UPS connected to an AC outlet at all times.
- Perform a full discharge/recharge cycle every 3-6 months if the UPS is rarely used on battery power.
- Batteries are consumable items and will eventually require replacement. Contact qualified service personnel for battery replacement.
2. التنظيف
- Disconnect the UPS from the AC power outlet and all connected devices before cleaning.
- Use a soft, dry cloth to wipe the exterior surfaces. Do not use liquid or aerosol cleaners.
- تأكد من أن فتحات التهوية خالية من الغبار والحطام.
3. التخزين
- If storing the UPS for an extended period, turn it off and disconnect it from all power sources.
- يخزن في مكان بارد وجاف.
- Recharge the UPS battery every 3 months to prevent battery degradation.
استكشاف الأخطاء وإصلاحها
Review the following common issues and solutions before contacting technical support.
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| لا يتم تشغيل UPS. | No AC input power. Battery deeply discharged. | Check AC power cord connection. Ensure wall outlet has power. Allow UPS to charge for 8 hours. |
| UPS beeps continuously in AC mode. | Overload condition. Internal fault. | Reduce connected load. Disconnect non-essential devices. If problem persists, contact support. |
| يتحول UPS إلى وضع البطارية بشكل متكرر. | Unstable utility power. Low battery capacity. | Check utility power quality. Allow battery to fully charge. Consider battery replacement if old. |
| Connected devices lose power during outage. | UPS overloaded. Battery depleted. | Ensure total load is within capacity. Allow UPS to recharge. |
تحديد
| ميزة | مواصفة |
|---|---|
| نموذج | UPSD2000VBK |
| ماركة | نيديس |
| سعة | 2000 فولت أمبير / 1200 واط |
| حجم الإدخالtage | 120 فولت (تيار متردد) |
| مآخذ الإخراج | 4 (Schuko type) |
| الأبعاد (الطول × العرض × الارتفاع) | 14.5 × 40 × 20.5 سم |
| وزن | 30 كجم |
| نوع البطارية | Sealed Lead-Acid (internal, non-user replaceable) |
| وقت الشحن | 8 hours to 90% capacity (typical) |
| درجة حرارة التشغيل | 0 درجة مئوية إلى 40 درجة مئوية |
| رطوبة | 0-90% رطوبة نسبية (بدون تكاثف) |
| منفذ الاتصالات | USB |
| حماية الشبكة | RJ45 (IN/OUT) |
الضمان والدعم
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Nedis website. Do not attempt to repair the unit yourself, as this may void your warranty and pose safety risks. Always contact qualified service personnel for assistance.