1. المقدمة
The Atrix VACOHCS HEPA Certified Vacuum is designed for efficient and safe cleaning, particularly in environments requiring ultra-fine filtration. This manual provides essential information for the proper setup, operation, and maintenance of your vacuum to ensure optimal performance and user safety.
2. معلومات السلامة
Always read and understand all safety warnings and instructions before operating this appliance. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.
- Ensure the vacuum is unplugged before performing any maintenance or changing accessories.
- Do not use the vacuum on wet surfaces or to pick up liquids. This vacuum is designed for dry hazardous material cleanup.
- احتفظ بالشعر والملابس الفضفاضة والأصابع وجميع أجزاء الجسم بعيدًا عن الفتحات والأجزاء المتحركة.
- استخدم فقط كما هو موضح في هذا الدليل. استخدم فقط الملحقات الموصى بها من قبل الشركة المصنعة.
- توخى الحذر الشديد عند تنظيف السلالم.
- لا تلتقط أي شيء يحترق أو يصدر دخانًا، مثل السجائر أو أعواد الثقاب أو الرماد الساخن.
- The vacuum is equipped with a short electrical cord. Always use a suitable extension cord that is in good condition and rated for the vacuum's power requirements.
3. محتويات العبوة
تأكد من تضمين جميع العناصر المدرجة أدناه في الحزمة الخاصة بك:
- VACOHCS HEPA Vacuum Unit
- OF612HE-IC HEPA CERTIFIED Filter Cartridge
- سلك كهرباء بطول 25 قدم
- أداة الشقوق
- فرشاة تنظيف الشقوق
- Utility Nozzle and Brush
- 19" Wand
- خرطوم شفاف
- (2) Hose Plugs
- حزام كتف قابل للتعديل

Figure 3.1: The Atrix VACOHCS HEPA Certified Vacuum kit, neatly organized within its durable red carrying case, showcasing the main unit, filter, and various accessories.
4. الإعداد
Follow these steps for initial setup of your Atrix VACOHCS vacuum:
- قم بتوصيل الخرطوم: Connect the clear hose to the vacuum's intake port. Ensure a secure fit to prevent loss of suction.
- تجميع العصا: Connect the 19" wand to the hose. Attach the desired cleaning tool (crevice tool, utility nozzle, etc.) to the end of the wand.
- توصيل الطاقة: Plug the vacuum's pigtail cord into a suitable 3-prong extension cord. Utilize the cord relief feature on the vacuum to alleviate pressure on the pigtail cord connection.
- Wear the Backpack: Adjust the shoulder straps and waist strap for a comfortable and secure fit. The ergonomic design allows for airflow between your back and the unit.
Video 4.1: This video demonstrates the assembly, ergonomic features, and practical use of the Atrix Ergo Pro Backpack Vacuum, including how to wear it comfortably and attach accessories.

Figure 4.2: A person wearing the Atrix VACOHCS backpack vacuum, demonstrating its ergonomic design and portability during a cleaning task.
5. تعليمات التشغيل
The Atrix VACOHCS is designed for versatile cleaning across various surfaces.
- تشغيل/إيقاف التشغيل: Locate the power switch on the side of the vacuum unit. Flip the switch to the 'ON' position to start the vacuum.
- تنظيف السطح: Select the appropriate attachment for your cleaning task. Use the utility nozzle for general cleaning on hard floors, carpets, and upholstery. The crevice tool is ideal for tight spaces and edges.
- Adjusting the Wand: The 19" wand is extendable. Adjust its length to comfortably reach high or low areas without straining.
- وظيفة المنفاخ: This vacuum can also function as a blower. Consult the full product manual for instructions on converting the unit to blower mode and using the specialized blower attachments.

Figure 5.1: A man efficiently cleaning a hard floor surface using the Atrix vacuum with its extended wand and floor tool, highlighting its versatility for different floor types.
6. الصيانة
Regular maintenance ensures the longevity and efficiency of your Atrix VACOHCS vacuum, especially regarding its HEPA filtration system.
- استبدال خرطوشة الفلتر: The VACOHCS uses an OF612HE-IC HEPA CERTIFIED Filter Cartridge. This is a sealed system designed for safe and simple replacement. When the filter is full, simply plug the intake and exhaust ports of the cartridge with the provided plugs, then pull the tabs to remove it. Dispose of the old filter according to local regulations for hazardous waste. Install a new filter cartridge by aligning it correctly and ensuring it clicks into place.
- No Secondary Filters: The sealed filter cartridge design eliminates the need for secondary or tertiary filters, reducing cross-contamination risks during changes.
- النظافة العامة: امسح الجزء الخارجي من المكنسة الكهربائية بالإعلانamp cloth as needed. Ensure all ports and connections are free of debris.
فيديو 6.1: أكثر منview of the ATRIX SafeGuard 360 filter system, detailing its components and the benefits of its sealed design for safe and simple filter changes.
Video 6.2: This video highlights the features and benefits of the ATRIX SafeGuard 360 HEPA H13 Certified Filter, emphasizing its individual testing and high efficiency for capturing fine particles.
7. المواصفات
| ميزة | مواصفة |
|---|---|
| ماركة | ATRIX |
| اسم الموديل | VACOHCS |
| ميزة خاصة | حبالي |
| نوع الفلتر | Cartridge (OF612HE-IC HEPA Certified) |
| المكونات المضمنة | HEPA Filter, 25 ft power cord, crevice tool, crevice tool brush, utility nozzle and brush, 19" wand, clear hose, (2) hose plugs, adjustable shoulder strap |
| هل هو لاسلكي؟ | لا |
| الاستخدامات الموصى بها للمنتج | Carpet, Desk, Furniture, Hard Floor, Tile Floor, Hardwood, Rug, Garage, Bare Floor, Sofa |
| عامل الشكل | Handheld (with backpack harness) |
| لون | أبيض |
| مستوى الضوضاء | 73 ديسيبل |
| Ampإيراج | 5.23 Amps |
| عدد العناصر | 1 |
| نوع وحدة التحكم | التحكم باليد |
| قوة حصان | 0.84 حصان |
| طريقة التحكم | يلمس |
| أسلوب | مضغوط |
| محمول | No (designed to be worn) |
| عدد مستويات الطاقة | 1 |
| الاستخدام الداخلي والخارجي | داخلي |
| أقصى قوة حصان | 0.84 حصان |
| تقنية تجميع الشفط | الشفط |
| رمز المنتج الموحد | 838067003296 |
| أبعاد الحزمة | 20 × 9 × 6 بوصة |
| ASIN | B078Y7FTJM |
| توصية السطح | جميع الطوابق |
| مصدر الطاقة | كهرباء سلكية |
8. استكشاف الأخطاء وإصلاحها
If you encounter issues with your Atrix VACOHCS vacuum, consider the following common troubleshooting steps:
- لا يوجد طاقة: Check if the power cord is securely plugged into both the vacuum and a functioning electrical outlet. Ensure the extension cord is not damaged.
- فقدان الشفط: Inspect the hose and attachments for blockages. Verify that the filter cartridge is correctly installed and not completely full.
- ضوضاء غير عادية: Turn off the vacuum immediately. Check for any foreign objects lodged in the hose, wand, or attachments. Ensure the filter is properly seated.
- ارتفاع درجة الحرارة: If the vacuum shuts off unexpectedly, it may be due to overheating. Unplug the unit and allow it to cool down for at least 30 minutes. Check for blockages or a full filter that might be restricting airflow.
For persistent issues, please contact Atrix customer support.
9. الضمان والدعم
For information regarding product warranty, returns, or technical support, please refer to the official Atrix webالموقع أو تواصل مع خدمة العملاء مباشرةً. احتفظ بإيصال الشراء كإثبات للشراء في حال وجود أي مطالبات بالضمان.