This manual provides essential instructions for the proper setup, operation, and maintenance of your Dwyer 400-23-GAGE Air Velocity Meter. Please read this manual thoroughly before using the device to ensure accurate measurements and safe operation. Retain this manual for future reference.

المنتج انتهىview

The Dwyer 400-23-GAGE is a precision instrument designed for measuring air velocity. It typically includes a manometer, pitot tube, tubing, and necessary accessories for field use. This device is suitable for various industrial and scientific applications requiring accurate airflow measurement.

Dwyer 400-23-GAGE Air Velocity Meter kit including manometer, pitot tube, tubing, and carrying case.

الشكل 1: Dwyer 400-23-GAGE Air Velocity Meter kit. This image displays the complete kit, including the inclined manometer, a pitot tube, connecting tubing, and a protective carrying case. Also visible are small bottles, likely containing manometer fluid, and instruction sheets.

يثبت

  1. فك التعبئة: Carefully remove all components from the packaging. Verify that all items listed in the packing list are present and undamaged.
  2. Manometer Fluid Filling: If the manometer is not pre-filled, carefully add the specified manometer fluid (typically included) to the reservoir until it reaches the indicated zero mark. Refer to the specific instructions on the manometer itself for precise filling procedures. Avoid overfilling or introducing air bubbles.
  3. اتصال الأنابيب: Connect one end of the flexible tubing to the high-pressure port of the manometer and the other end to the total pressure port of the pitot tube. Connect a second piece of tubing from the low-pressure port of the manometer to the static pressure port of the pitot tube. Ensure all connections are secure and airtight.
  4. Pitot Tube Placement: Position the pitot tube in the airflow stream at the desired measurement point. Ensure the tip of the pitot tube is facing directly into the airflow for accurate readings.
  5. Leveling the Manometer: Place the manometer on a stable, level surface or mount it securely. Use the integrated leveling bubble (if present) or a separate level to ensure the manometer is perfectly horizontal. This is critical for accurate inclined manometer readings.

تعليمات التشغيل

  1. التعديل الصفري: Before taking any measurements, ensure the manometer fluid level is at the zero mark when no pressure is applied. Adjust the zeroing knob if necessary.
  2. أخذ القراءات: With the pitot tube correctly positioned in the airflow, observe the fluid level in the manometer. The difference in fluid height indicates the differential pressure.
  3. Velocity Calculation: Use the provided air velocity calculation chart or formula (typically printed on the manometer or in accompanying documentation) to convert the differential pressure reading (in inches of water) into air velocity (e.g., feet per minute or meters per second). This calculation often requires knowing the air density, which can vary with temperature and atmospheric pressure.
  4. قراءات متعددة: For improved accuracy, take several readings at different points within the airflow duct or area and average them.
  5. الاعتبارات البيئية: Ensure the operating environment is within the specified temperature and humidity ranges for the instrument to maintain accuracy.

صيانة

  • فحص مستوى السوائل: Regularly check the manometer fluid level and replenish if necessary. Use only the manufacturer-specified fluid.
  • تنظيف: Keep the manometer and pitot tube clean. Use a soft, damp cloth for the exterior. Ensure the pitot tube openings are free from obstructions.
  • فحص الأنابيب: Periodically inspect the connecting tubing for cracks, kinks, or leaks. Replace damaged tubing immediately to prevent inaccurate readings.
  • تخزين: When not in use, store the instrument in its protective carrying case in a clean, dry environment, away from extreme temperatures and direct sunlight. Ensure the manometer fluid is secured to prevent spillage.
  • معايرة: For critical applications, periodic calibration by a qualified service center is recommended to maintain measurement accuracy.

استكشاف الأخطاء وإصلاحها

  • No Reading or Erratic Readings:
    • Check for kinks or blockages in the tubing.
    • Ensure tubing connections are secure and airtight.
    • Verify the pitot tube is correctly positioned in the airflow.
    • Check manometer fluid level and for air bubbles.
    • Ensure the manometer is level.
  • قراءات غير دقيقة:
    • Confirm the manometer is properly zeroed.
    • Verify the correct air density is used in velocity calculations.
    • Check for any physical damage to the pitot tube or manometer.
    • Consider professional calibration if accuracy issues persist.

تحديد

نموذج400-23-GAGE
ماركةدواير
الشركة المصنعةدواير
أبعاد الحزمة13 × 3 × 3 بوصة
وزن الحزمة17.4 رطل
ASINB077NJWHYB

Note: Specific measurement ranges and accuracy details are typically found on the device itself or in supplementary documentation.

المستندات ذات الصلة - 400-23-GAGE

قبلview جهاز قياس الضغط الرقمي المحمول من سلسلة دواير 477AV: المواصفات، التركيب، وتعليمات التشغيل
دليل شامل لجهاز قياس الضغط الرقمي المحمول Dwyer Series 477AV، يغطي المواصفات والتركيب وتعليمات التشغيل والميزات والصيانة لقياسات الضغط والتدفق والسرعة.
قبلview مواصفات جهاز قياس سرعة الهواء الشبكي من سلسلة دواير 160G وجهاز قياس درجة الحرارة/الرطوبة المحمول باليد من سلسلة 485B
المواصفات التفصيلية لشبكة متوسط ​​سرعة الهواء من سلسلة Dwyer 160G وجهاز قياس درجة الحرارة والرطوبة الرقمي المحمول باليد من سلسلة 485B، بما في ذلك الميزات والتطبيقات والمعايير الفنية.
قبلview مقياس الضغط التفاضلي المغناطيسي دواير - النشرة أ-27
المواصفات الفنية ودليل التركيب والتشغيل واستكشاف الأخطاء وإصلاحها لأجهزة قياس الضغط التفاضلية Dwyer Magnehelic، السلسلة 2000.
قبلview مقياس الضغط التفاضلي المغناطيسي دواير - النشرة A-27
نشرة فنية توضح بالتفصيل مقياس الضغط التفاضلي Dwyer Magnehelic، بما في ذلك المواصفات والتركيب والتشغيل واستكشاف الأخطاء وإصلاحها لمختلف الموديلات.
قبلview Dwyer Series A3000 Photohelic Differential Pressure Switch/Gage User Guide
User's guide for the Dwyer Series A3000 Photohelic Differential Pressure Switch/Gage, detailing its specifications, installation, electrical connections, and maintenance.
قبلview عدادات الطاقة بالموجات فوق الصوتية من سلسلة دواير TUF: مراقبة التدفق ودرجة الحرارة
المواصفات التفصيلية والميزات والتطبيقات ومعلومات الطلب لأجهزة قياس الطاقة بالموجات فوق الصوتية من سلسلة Dwyer TUF، المصممة لمراقبة التدفق ودرجة الحرارة بدقة باستخدام اتصالات Modbus® أو BACnet.