1. المقدمة
This manual provides essential information for the safe and efficient operation of your Immergas Victrix Tera 24KW Condensing Boiler. It is crucial to read and understand all instructions before installation, operation, or maintenance. Keep this manual in a safe place for future reference.
المنتج انتهىview
The Immergas Victrix Tera 24KW is a high-efficiency condensing boiler designed for domestic heating and hot water production. Its advanced technology ensures optimal performance and energy savings.

الشكل 1: أمام view of the Immergas Victrix Tera 24KW Condensing Boiler, showing the control panel and pressure gauge. This image illustrates the compact design and user interface of the unit.
2. معلومات السلامة
Safety is paramount when dealing with gas appliances. Failure to follow these instructions could result in property damage, personal injury, or death.
- التثبيت الاحترافي: This appliance must be installed by a qualified and certified professional in accordance with all local and national regulations.
- تهوية: Ensure adequate ventilation in the installation area as required by local codes. Do not obstruct air vents.
- تسرب الغاز: If you smell gas, do not operate electrical switches, light matches, or use any flame. Immediately open windows and doors, evacuate the building, and call your gas supplier or fire department.
- أول أكسيد الكربون: Install carbon monoxide detectors in your home. Carbon monoxide is an odorless, colorless gas that can be fatal.
- صيانة: Regular maintenance by a qualified technician is essential for safe and efficient operation.
- الأطفال والحيوانات الأليفة: Keep children and pets away from the boiler.
- ضغط الماء: Regularly check the system water pressure as indicated on the boiler's gauge.
3. الإعداد
Installation should only be performed by a qualified heating engineer.
فحوصات ما قبل التثبيت:
- Verify that the boiler type (methane) matches the available gas supply.
- Ensure the installation site complies with all relevant building and safety regulations.
- Check that all necessary connections (gas, water, electrical, flue) are accessible and correctly sized.
Installation Steps (Summary for reference):
- التركيب: Securely mount the boiler to a suitable wall using the provided template and fixings. Ensure it is level.
- نظام المداخن: Install the flue system according to manufacturer's instructions and local regulations for safe exhaust of combustion products.
- التوصيلات الهيدروليكية: Connect the heating flow and return pipes, domestic hot water inlet and outlet, and condensate drain. Ensure all connections are watertight.
- توصيل الغاز: Connect the gas supply line to the boiler's gas inlet, ensuring a gas-tight seal and proper isolation valve installation.
- التوصيل الكهربائي: Connect the boiler to the main electrical supply via a fused spur, following the wiring diagram in the full installation manual.
- Filling and Purging: Fill the heating system with water and thoroughly purge air from the system. Check for leaks.
- التكليف: A qualified engineer must perform the initial commissioning, including gas pressure checks, combustion analysis, and functional tests.
4. تعليمات التشغيل
Once installed and commissioned by a professional, operating your Immergas boiler is straightforward.
انتهت لوحة التحكمview:
The boiler features a digital display and several buttons for adjusting settings. Refer to the detailed diagram in the full manual for specific button functions.
التشغيل الأساسي:
- تشغيل/إيقاف التشغيل: Use the main power switch (usually located near the boiler) to turn the unit on or off. The display will illuminate when powered on.
- Heating Temperature Adjustment: Use the '+' and '-' buttons, typically marked with a radiator icon, to set your desired central heating temperature.
- Domestic Hot Water (DHW) Temperature Adjustment: Use the '+' and '-' buttons, typically marked with a tap icon, to set your desired domestic hot water temperature.
- أوضاع التشغيل: The boiler may have different operating modes (e.g., Summer, Winter, Auto). Select the appropriate mode using the mode selection button.
- فحص ضغط النظام: Regularly observe the pressure gauge on the boiler. The optimal pressure range is typically between 1.0 and 1.5 bar when the system is cold. If the pressure drops below 1.0 bar, repressurize the system using the filling loop (refer to the full manual for detailed instructions).
رموز الخطأ:
If an issue occurs, the boiler's display may show an error code. Note down the code and consult the troubleshooting section of this manual or the comprehensive error code list in the full Immergas manual. Do not attempt repairs yourself; contact a qualified technician.
5. الصيانة
Regular maintenance ensures the longevity, efficiency, and safe operation of your Immergas boiler.
- الخدمة المهنية السنوية: It is mandatory to have your boiler serviced annually by a Gas Safe registered (or equivalent national standard) engineer. This service includes checking combustion, gas pressure, safety devices, and cleaning components.
- ضغط النظام: Periodically check the system pressure on the boiler's gauge. If it consistently drops, there may be a leak in the system that needs professional attention.
- تنظيف: حافظ على نظافة الجزء الخارجي من الغلاية باستخدام قطعة قماش ناعمة.amp cloth. Do not use abrasive cleaners or solvents. Ensure air vents are clear of obstructions.
- الحماية من الصقيع: If the boiler is installed in an unheated area, ensure the frost protection function is active (if available) or take appropriate measures to prevent freezing during cold periods.
- جفاف: Ensure the condensate drain pipe is not blocked and is free-flowing.
6. استكشاف الأخطاء وإصلاحها
Before calling a service technician, you can perform some basic checks for common issues.
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| لا يوجد تدفئة أو ماء ساخن | No power, low system pressure, thermostat setting too low, gas supply off. | Check power supply, check pressure gauge and repressurize if needed, adjust thermostat, ensure gas valve is open. |
| ضغط نظام منخفض | Minor leak, system not adequately filled. | Repressurize the system using the filling loop. If pressure drops frequently, contact a qualified technician for leak detection. |
| يصدر المرجل أصواتًا غير عادية | Air in the system, limescale build-up, pump issue. | Bleed radiators to remove air. For persistent noises or suspected limescale, contact a qualified technician. |
| الغلاية تعرض رمز خطأ | Internal fault, sensor issue, component failure. | Note the error code. Attempt to reset the boiler (refer to full manual). If the code persists, contact a qualified Immergas service technician, providing the error code. |
مهم: For any issue not resolved by these basic steps, or if you are unsure, always contact a qualified and certified heating engineer. Do not attempt complex repairs yourself.
7. المواصفات
Key technical specifications for the Immergas Victrix Tera 24KW Condensing Boiler:
| الشركة المصنعة | إيمرجاس |
| أبعاد المنتج (الطول × العرض × الارتفاع) | 40 × 30 × 76 سم |
| رقم موديل العنصر | 3027368 |
| مقاس | صغير |
| لون | بيانكو (أبيض) |
| أسلوب | 24 كيلو واط |
| كمية العناصر | 1 |
| المكونات المضمنة | المرجل |
| البطاريات المتضمنة | لا |
| البطاريات المطلوبة | لا |
| وزن | 36 جرام |
| توافر قطع الغيار | معلومات غير متوفرة عن قطع الغيار |
| تاريخ التوفر الأول على Amazon.com.be | 25 أبريل 2022 |
| تم إيقافه من قبل الشركة المصنعة | لا |
8. الضمان والدعم
Your Immergas Victrix Tera 24KW Condensing Boiler is covered by a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Immergas webالموقع للحصول على معلومات مفصلة.
دعم العملاء:
For technical assistance, spare parts, or warranty claims, please contact your authorized Immergas dealer or a certified service center. Ensure you have your boiler's model number (3027368) and serial number ready when contacting support.
For general inquiries, you may also visit the official Immergas website or consult their local distributors for contact information.