This manual provides essential information for the safe and effective installation, operation, and maintenance of the Allanson Industrial Gas Ignitor, Model 2260-TP. This electronic ignition transformer is designed for industrial gas applications, providing reliable ignition for various heating systems.

Allanson Industrial Gas Ignitor Model 2260-TP

الشكل 1: Allanson Industrial Gas Ignitor Model 2260-TP. This image displays the black rectangular electronic ignition transformer with a white label. The label clearly shows 'Allanson ELECTRONIC IGNITION TRANSFORMER CAT No. 2260-TP', along with primary and secondary voltage/current ratings. It also indicates 'MADE IN CANADA'. Electrical wires are visible, connected to one side of the unit.

2. معلومات السلامة

تحذير: Installation and servicing of this ignitor must be performed by a qualified and licensed professional. Failure to follow these instructions could result in property damage, personal injury, or death.

3. انتهى المنتجview

The Allanson 2260-TP is an electronic ignition transformer designed to provide a high-voltage spark for igniting gas in industrial heating systems. It converts standard line voltage to a high-voltage output, ensuring reliable and efficient ignition.

المميزات الرئيسية:

4. الإعداد والتثبيت

قبل أن تبدأ:

  1. Ensure the power supply matches the ignitor's specifications (120V, 50/60Hz).
  2. Confirm the ignitor is compatible with your specific heating system.
  3. Gather necessary tools: screwdrivers, wire strippers, multimeter, mounting hardware.

خطوات التثبيت:

  1. انقطاع التيار الكهربائي: Turn off all power to the heating system at the main circuit breaker. Verify power is off using a multimeter.
  2. Remove Old Ignitor (if applicable): Carefully disconnect wiring and mounting hardware from the existing ignitor. Note wire connections for reference.
  3. التركيب: Securely mount the Allanson 2260-TP ignitor in the designated location using appropriate hardware. Ensure it is stable and free from vibration.
  4. التوصيلات الكهربائية: Connect the primary (input) wires to the 120V AC power supply according to the wiring diagram of your appliance. Connect the secondary (output) wires to the spark electrode or ignition rod. Ensure all connections are tight and insulated. Refer to the label on the ignitor for specific primary and secondary connections.
  5. التأريض: Ensure the ignitor and the appliance are properly grounded.
  6. الفحوصات النهائية: Double-check all wiring connections. Ensure no loose wires or potential short circuits.

5. تعليمات التشغيل

The Allanson 2260-TP ignitor operates automatically as part of the heating system's control sequence. Once properly installed and wired, it will generate a high-voltage spark when called upon by the system's control board to ignite the gas burner.

ليشغل:

  1. Ensure all installation steps are completed and verified.
  2. أعد تشغيل نظام التدفئة.
  3. Initiate a call for heat from the thermostat or control system.
  4. Observe the ignitor's operation. It should produce a visible spark at the electrode, leading to gas ignition.
  5. If ignition does not occur, refer to the Troubleshooting section.

6. الصيانة

The Allanson 2260-TP ignitor is designed for long-term reliability with minimal maintenance. However, periodic inspection of the entire ignition system is recommended as part of routine appliance servicing.

7. استكشاف الأخطاء وإصلاحها

If the ignitor is not functioning correctly, perform the following checks. Always disconnect power before inspecting components.

مشكلة السبب المحتمل حل
No Spark from Ignitor
  • لا يوجد طاقة للإشعال.
  • خلل في توصيل الأسلاك.
  • المشعل المعيب.
  • لوحة تحكم معيبة.
  • التحقق من قاطع الدائرة ومصدر الطاقة.
  • تأكد من أن جميع توصيلات الأسلاك آمنة.
  • Test ignitor for proper voltage output (requires specialized equipment and knowledge).
  • Consult appliance manual for control board diagnostics.
Intermittent Spark/Ignition
  • وصلات الأسلاك فضفاضة.
  • Dirty or worn spark electrode.
  • إمداد الطاقة المتقلب.
  • أحكم ربط جميع التوصيلات الكهربائية.
  • Clean or replace the spark electrode.
  • Have an electrician check the power supply.
Ignitor Sparks but No Gas Ignition
  • لا يوجد مصدر للغاز.
  • صمام الغاز الخاطئ.
  • Blocked burner orifice.
  • فجوة شرارة غير مناسبة.
  • Check gas supply to the appliance.
  • Test gas valve operation.
  • Clean burner orifices.
  • Adjust spark gap according to appliance specifications.

If problems persist after troubleshooting, contact a qualified HVAC technician or the manufacturer for assistance.

8. المواصفات

يصف قيمة
الشركة المصنعة ألانسون
رقم القطعة 2260،XNUMX،XNUMX-TP
وزن العنصر 7 رطل
كمية حزمة العنصر 1
المجلد الابتدائيtagهـ / الحالية 120 فولت 50/60 هرتز 0.6 أمبير
المجلد الثانويtagهـ / الحالية 15.6 kVpk 28 mA
تاريخ أول توفر 18 أغسطس 2017

9. الضمان والدعم

Specific warranty information for the Allanson Industrial Gas Ignitor #2260-TP is not provided in this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact Allanson directly through their official webالموقع أو قنوات خدمة العملاء.

For technical support or further assistance, please reach out to a qualified HVAC professional or the manufacturer's support team.

المستندات ذات الصلة - 2260،XNUMX،XNUMX-TP

قبلview Allanson 2260 Series Electronic Ignitors Instruction Manual
Comprehensive instruction manual for Allanson 2260 series electronic ignitors (models 2260-TP, 2260-TPLP, 2260-TW, 2260-TWLP, 2260-P, 2260-TPLPJB). Includes installation, maintenance, testing, and mechanical specifications for commercial and industrial gas applications.
قبلview Allanson OMNI Electronic Ignitor Type 2275U Instruction Manual
Instruction manual for the Allanson OMNI Electronic Ignitor, Type 2275U, providing application details, specifications, installation, maintenance, and testing procedures for reliable ignition in gas and oil systems.
قبلview Allanson OMNI 2270U-3ST Electronic Ignitor Specification Guide
Detailed specification guide for the Allanson OMNI 2270U-3ST universal electronic ignitor, featuring a built-in 3-second timer and diagnostic tool for oil burner systems. Includes technical specifications, dimensions, and contact information.
قبلview Allanson 2270U-3ST OMNI Universal Electronic Ignitor Specification Guide
Detailed specification guide for the Allanson 2270U-3ST OMNI Universal Electronic Ignitor, featuring a built-in 3-second timer and diagnostic capabilities for oil burner systems.
قبلview Allanson Industrial Gas Transformers: Specifications and Cross-Reference Guide
Detailed specifications and cross-reference charts for Allanson Industrial Gas Transformers, covering models like 1092-H, 1092-PF-G, and others, with compatibility information for various burner manufacturers.
قبلview Allanson ACL-SC-DMX DMX Sub-Controller Installation Manual
This installation manual provides detailed instructions for the Allanson ACL-SC-DMX DMX Sub-Controller, covering specifications, port configurations, wiring diagrams, and important safety precautions for RGBW lighting systems.