1. المقدمة وما فوقview
The Solaxx SALTDIP™ 2-in-1 Electronic Salt Water Tester provides a fast and accurate method for measuring salt content and water temperature. This device eliminates the need for traditional reagents or test strips, offering digital readouts for confident results without color matching. It is designed for use in pools, spas, ponds, and aquariums.
تتضمن الميزات الرئيسية ما يلي:
- Rugged water resistant housing
- Commercial grade technology sensor
- Easy push buttons
- Large LCD readouts
- Temperature F°/C° toggle button
2. معلومات السلامة
Please read and understand all safety instructions before using the device. Proper handling ensures accurate readings and prolongs the life of your tester.
- Always wear protective eyewear and gloves when handling any chemical reagents or solutions.
- Avoid direct contact between test solutions and skin, eyes, nose, and mouth.
- Read all instructions and labels on any reagents thoroughly before use.
- Keep all reagents and testing equipment out of the reach of children and pets.
- اغسل يديك جيداً بالماء والصابون بعد كل استخدام.
- Dispose of used reagents and equipment according to local regulations.
3. محتويات العبوة
عند تفريغ الأغراض، تأكد من وجود جميع العناصر وأنها في حالة جيدة:
- Solaxx SALTDIP™ 2-in-1 Electronic Salt Water Tester Unit
- Protective Sensor Cap
- Sample Collection Cup (integrated or separate)
- 2 AAA Batteries (pre-installed or separate)
- دليل التعليمات/الدليل المرجعي
4. الإعداد
4.1 تركيب البطارية
The SALTDIP™ tester requires 2 AAA batteries. If not pre-installed, open the battery compartment located at the top of the unit, insert the batteries observing polarity, and securely close the compartment.
4.2 التحضير الأولي
Before first use, remove the protective sensor cap. If a small sponge is present inside the cap, ensure it is slightly moistened with clean water before replacing the cap for storage. This helps maintain sensor integrity.

Figure 1: Solaxx SALTDIP™ tester with protective cap removed, revealing the sensor probes.
5. تعليمات التشغيل
5.1 تشغيل/إيقاف التشغيل
اضغط مع الاستمرار على زر الطاقة (⏻) to turn the unit on or off. The LCD display will illuminate.
5.2 اختيار وضع القياس
The SALTDIP™ tester can measure salt content (PPM) and water temperature. Use the 'MODE/CAL' button to cycle through available measurement modes. Ensure 'SALT' is displayed on the screen for salt readings.
5.3 أخذ القياس
- جمع الماء سample using the integrated cup or a clean, separate container.
- Ensure the sensor probes at the bottom of the tester are clean.
- Immerse the sensor end of the tester into the water sample, ensuring the probes are fully submerged but not exceeding the 'MAX IMMERSION LINE' if indicated.
- Wait a few seconds for the reading to stabilize on the LCD display.
- Record your readings.

Figure 2: The Solaxx SALTDIP™ tester ready for use, displaying its digital interface.
5.4 تغيير وحدات درجة الحرارة
Press the 'HOLD/TEMP' button to toggle between Fahrenheit (F°) and Celsius (C°) temperature readings.

Figure 3: Key features of the SALTDIP™ tester, including the temperature toggle button.
6. فهم القراءات
The SALTDIP™ tester provides readings for salt content in Parts Per Million (PPM) and water temperature. Refer to your pool, spa, or aquarium manufacturer's guidelines for ideal salt and temperature ranges.
For swimming pools, a common ideal salt range is typically between 2700-3400 PPM. Readings outside this range may indicate a need for adjustment:
- < 2700 PPM: Poor disinfection effect.
- 2700-3400 PPM: Ideal Range.
- 3400-4500 PPM: Marginally Acceptable.
- > 4500 PPM: Highly Corrosive.

Figure 4: The SALTDIP™ tester measures both salt content and water temperature.
7. الصيانة
7.1 تنظيف المستشعر
After each use, rinse the sensor probes thoroughly with clean tap water to remove any residue from the tested water. This prevents buildup and ensures accurate future readings.
7.2 التخزين
Always replace the protective sensor cap after cleaning. Store the tester in a cool, dry place away from direct sunlight and extreme temperatures. If the cap contains a sponge, ensure it remains slightly moist to protect the sensor.
8. استكشاف الأخطاء وإصلاحها
- قراءات غير دقيقة أو غير متسقة: Ensure the sensor probes are clean. Re-calibrate the device if necessary (refer to the included reference guide for calibration steps). Check battery levels and replace if low.
- Dim or Blank LCD Display: This typically indicates low battery power. Replace the 2 AAA batteries.
- الوحدة لا تعمل: تحقق من تركيب البطارية وتأكد من أن البطاريات جديدة.
If issues persist after attempting these troubleshooting steps, please contact customer support.
9. المواصفات
- ماركة: سولاكس
- رقم الموديل: رقم NP2064
- مصدر الطاقة: تعمل بالبطارية (تتطلب بطاريتين AAA، متضمنة)
- لون: أسود
- وزن السلعة: 2.4 أونصة (0.15 رطل)
- أبعاد المنتج (الطول × العرض × الارتفاع): 6 × 2 × 11 بوصة
- تصنيف درجة الحرارة العليا: 100 درجة مئوية
- رمز المنتج العالمي: 859535002207
- الشركة المصنعة: SCP Distributors LLC (Pool Corp)
10. الضمان والدعم
The Solaxx SALTDIP™ 2-in-1 Electronic Salt Water Tester comes with a ضمان محدود لمدة عامين. For warranty claims, technical support, or any questions regarding the product, please contact SCP Distributors LLC (Pool Corp) customer service.
يرجى الاحتفاظ بإثبات الشراء للتحقق من صحة الضمان.