فلوك TL175

دليل مستخدم أسلاك اختبار Fluke TL175 TwistGuard

الموديل: TL175

1. المقدمة

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. معلومات السلامة

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • لا تستخدم أكثر من الحجم المقدرtage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • توخ الحذر عند العمل مع المجلدtagأعلى من 30 فولت تيار متردد RMS، أو 42 فولت ذروة، أو 60 فولت تيار مستمر. هذه الفولتياتtagإنها تشكل خطر صدمة.

3. مواصفات المنتج

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

الشكل 1: انتهىview of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. الإعداد والتثبيت

  1. Inspect Leads: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. Connect to Instrument: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. تعليمات التشغيل

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • المجلدtagالقياس ه: حدد المجلد المناسبtage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • القياس الحالي: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Resistance/Continuity: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. الصيانة

  • تنظيف: Clean the test leads with a damp قماش ومنظف معتدل. لا تستخدم المنظفات الكاشطة أو المذيبات.
  • تقتيش: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • تخزين: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

7. استكشاف الأخطاء وإصلاحها

  • No Reading or Intermittent Reading:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • قراءات غير دقيقة:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. المواصفات

ميزةمواصفة
رقم الموديلتي ال 175
تصنيف السلامةCAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
مادة سلك الرصاصDouble Insulated Silicone
درجة حرارة التشغيل-20 إلى 55 درجة مئوية (-4 إلى 131 درجة فهرنهايت)
ارتفاع2000m (6,562')
امتثالEN61010-031
أبعاد المنتج10 × 3 × 2 بوصة
وزن العنصر120 جرام (4.23 أونصة)

ماذا يوجد في الصندوق:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. الضمان والدعم

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke webموقع.

الشركة المصنعة: شركة فلوك

تاريخ التوفر الأول: 1 يونيو 2011

المستندات ذات الصلة - تي ال 175

قبلview جهاز فلوك 179 متعدد القياسات الرقمي: دليل الصيانة والخدمة الميدانية
اكتشف جهاز فلوك 179 الرقمي متعدد القياسات ذو التربيع الجذري الحقيقي، المصمم لصيانة فعّالة للكهرباء وأنظمة التدفئة والتهوية وتكييف الهواء. تعرّف على ميزاته ومواصفاته وملحقاته الموصى بها لخدمة ميدانية موثوقة.
قبلview دليل مستخدم أجهزة القياس الرقمية المتعددة من فلوك 15B+/17B+/18B+
Comprehensive user manual for Fluke 15B+, 17B+, and 18B+ digital multimeters, covering features, operation, safety, maintenance, and specifications. This document provides detailed instructions for using the multimeters for various electrical measurements.
قبلview Fluke 106/107 Palmsized Digital Multimeters: Technical Specifications and Features
Detailed technical specifications, product highlights, and general information for the Fluke 106 and 107 palmsized digital multimeters. Learn about their electrical specifications, accuracy, features, and included equipment.
قبلview جهاز فلوك 107 الرقمي المحمول متعدد القياسات من الفئة الثالثة - المواصفات الفنية
المواصفات الفنية التفصيلية والميزات والمعلومات العامة لجهاز فلوك 107 الرقمي المحمول من الفئة الثالثة. يشمل ذلك القياسات الكهربائية وتصنيفات السلامة وتفاصيل الطلب.
قبلview مجموعة محولات Fluke FEV100 لمحطات شحن المركبات الكهربائية: البيانات الفنية والمواصفات
استكشف المواصفات الفنية والميزات وإجراءات الاختبار لمجموعة محولات Fluke FEV100، المصممة لاختبار محطات شحن المركبات الكهربائية (EVSE) بأمان وكفاءة. تتضمن معلومات السلامة والتوافق وتفاصيل الطلب.
قبلview جهاز فلوك 110 متعدد القياسات بتقنية True-RMS: المواصفات الفنية والميزات
المواصفات والميزات التفصيلية لجهاز فلوك 110 متعدد القياسات المدمج بتقنية True-RMS، المصمم خصيصًا لتركيبات الكهرباء الدقيقة وتشخيص الأعطال. يتضمن ذلك دقة القياس، وتصنيفات السلامة، والملحقات المرفقة.