Sealey IHS1

Sealey IHS1 Stand for IWMH1809R/IFSH1809R Heaters - Instruction Manual

Model: IHS1

1. المقدمة

This manual provides essential instructions for the safe assembly, operation, and maintenance of your Sealey IHS1 stand. This stand is designed to convert the Sealey IWMH1809R wall-mounted infrared heater into a freestanding IFSH1809R unit. Please read these instructions thoroughly before use and retain them for future reference.

Sealey IHS1 Stand with Heater

Figure 1: The Sealey IHS1 stand with a compatible infrared heater installed, showcasinتصميمه القائم بذاته.

2. تعليمات السلامة

Always observe the following safety precautions to prevent personal injury or damage to the product.

  • Ensure the stand is assembled on a flat, stable, and level surface.
  • Do not exceed the maximum weight capacity of the stand. This stand is specifically designed for Sealey IWMH1809R/IFSH1809R heaters.
  • Regularly inspect all fasteners and connections to ensure they are secure.
  • Keep children and pets away from the stand and attached heater during operation.
  • Do not attempt to modify the stand in any way.
  • When moving the stand with the heater attached, ensure the heater is switched off and cooled, and move with care to prevent tipping.

3. محتويات العبوة

تأكد من وجود جميع المكونات قبل البدء بالتجميع:

  • 1 x Sealey IHS1 Stand Assembly (includes base, pole sections, and mounting bracket)
  • Required Fasteners and Tools (if applicable, refer to heater manual for heater-specific fasteners)

4. الإعداد والتجميع

Follow these steps to assemble the IHS1 stand and attach your compatible heater.

  1. تجميع القاعدة: Place the stand base on a flat, stable surface. Ensure the base is fully seated and stable.
    Close-up of the stand's circular base

    Figure 2: The robust circular base of the Sealey IHS1 stand, designed for stability.

  2. تركيب أجزاء العمود: Securely connect the pole sections to the base and to each other, following the instructions provided with the stand's packaging. Ensure all connections are tightened.
  3. تركيب السخان: Attach your Sealey IWMH1809R heater to the top mounting bracket of the IHS1 stand. Refer to your heater's instruction manual for specific mounting hardware and procedures. Ensure the heater is securely fastened and balanced on the stand.
  4. إدارة الكابلات: Route the heater's power cable along the stand pole using the provided cable clips to prevent tripping hazards and maintain a tidy appearance.
    Cable management clip on stand pole

    الشكل 3: لقطة مقربة view of the cable management clip on the stand's pole, used to secure the power cord.

5. تعليمات التشغيل

The IHS1 stand provides a stable platform for your heater. Its primary operational feature is height adjustment.

  1. ضبط الارتفاع: To adjust the height of the heater, loosen the height adjustment collar on the stand pole. Carefully raise or lower the upper pole section to the desired height (between 1340mm and 1700mm). Once the desired height is achieved, securely tighten the adjustment collar to lock the pole in place.
    Height adjustment mechanism on the stand

    Figure 4: The height adjustment collar on the stand's pole, allowing for variable height settings.

  2. التمركز: Place the stand with the attached heater in a location where it can provide optimal heating without obstruction. Ensure there is adequate clearance around the heater as specified in the heater's manual.
    Heater on stand in an outdoor setting

    Figure 5: The Sealey IHS1 stand with an infrared heater positioned outdoors, demonstrating its freestanding utility.

Note: For specific operating instructions regarding the heater's power, heat settings, and sensor functions, please refer to the instruction manual provided with your Sealey IWMH1809R/IFSH1809R heater. An example of a heater control panel is shown below for reference.

Heater control panel with ON, OFF, and SENSOR buttons

الشكل 6: مثالample of a control panel found on compatible Sealey heaters, featuring ON, OFF, and SENSOR buttons.

6. الصيانة

To ensure the longevity and safe operation of your IHS1 stand:

  • تنظيف: امسح الحامل بقطعة قماش ناعمة و...amp القماش. لا تستخدم المنظفات أو المذيبات الكاشطة.
  • تقتيش: Periodically check all bolts, screws, and connections for tightness. Retighten if necessary.
  • تخزين: If storing the stand for an extended period, disassemble it if desired and store in a dry, protected area.

7. استكشاف الأخطاء وإصلاحها

If you encounter issues with your IHS1 stand, consider the following:

  • عدم استقرار الموقف:
    • Ensure the stand is on a completely flat and level surface.
    • Verify all pole sections and the base are securely tightened.
    • Confirm the heater is properly centered and balanced on the mounting bracket.
  • صعوبة تعديل الارتفاع:
    • Ensure the height adjustment collar is fully loosened before attempting to adjust.
    • تأكد من عدم وجود أي عوائق أو حطام داخل أقسام الأعمدة.

For issues related to the heater's functionality, refer to the heater's specific instruction manual.

8. المواصفات

ميزةالتفاصيل
رقم الموديلIHS1
سخانات متوافقةSealey IWMH1809R, IFSH1809R
الحد الأدنى للارتفاع1340 ملم
الحد الأقصى للارتفاع1700 ملم
أبعاد المنتج (بعد التعبئة)حوالي 0.62 × 3.23 × 0.62 بوصة
وزن العنصر22.2 رطل (حوالي 10.07 كجم)
لونأسود

9. الضمان والدعم

This Sealey IHS1 stand comes with a ضمان لمدة 1 سنوات. For full terms and conditions, please refer to the official Sealey website or contact Sealey customer support.

شعار ضمان سيلي لمدة عام واحد

Figure 7: Sealey's 1 Year Guarantee emblem, indicating product assurance.

للحصول على المساعدة الفنية أو قطع الغيار أو مطالبات الضمان، يرجى الاتصال بوكيل Sealey المعتمد أو زيارة موقع Sealey الرسمي webالموقع للحصول على معلومات الدعم.

Please note: "Terms and conditions apply" as indicated by the manufacturer.

المستندات ذات الصلة - IHS1

قبلview دليل مستخدم سخان سيراميك سيلي بقدرة 1.2/2.4 كيلو واط مع حامل ثلاثي القوائم تلسكوبي - CH30110VS
دليل المستخدم لسخان السيراميك Sealey CH30110VS بقدرة 1.2/2.4 كيلو واط. يتضمن تعليمات السلامة، ودليل التشغيل، والمواصفات، والتجميع، والصيانة.
قبلview دليل مستخدم سخان سيلي IR55.V2 بالأشعة تحت الحمراء بقدرة 45.5 كيلوواط للكيروسين/البيروفين/الديزل
دليل مستخدم شامل لسخان الأشعة تحت الحمراء Sealey IR55.V2 بقدرة 45.5 كيلوواط. يغطي الدليل السلامة والمواصفات والتشغيل والصيانة واستكشاف الأعطال وإصلاحها لوقود البارافين والكيروسين والديزل.
قبلview دليل مستخدم سخان السيراميك Sealey 1.4/2.8 كيلو واط مع حامل ثلاثي القوائم تلسكوبي CH30S
دليل المستخدم لسخان السيراميك Sealey CH30S بقدرة 1.4/2.8 كيلو واط مع حامل ثلاثي القوائم قابل للتمديد. يتضمن تعليمات السلامة والمواصفات وتفاصيل التجميع والتشغيل والصيانة.
قبلview سخان غاز الأشعة تحت الحمراء Sealey LP14: دليل المستخدم وتعليمات السلامة
دليل مستخدم شامل وتعليمات سلامة لسخان الغاز بالأشعة تحت الحمراء Sealey LP14 الذي يعمل بالبروبان. يتضمن معلومات التركيب والتشغيل وتحذيرات السلامة والمواصفات للاستخدامات التجارية.
قبلview دليل تركيب وتشغيل سخان الكوارتز بالأشعة تحت الحمراء Sealey IWMH2003
تعليمات شاملة لسخان الكوارتز بالأشعة تحت الحمراء Sealey IWMH2003، تغطي السلامة والتركيب والتشغيل والمواصفات. تعرّف على كيفية تركيب واستخدام السخان بأمان.
قبلview Sealey IR15 Infrared Halogen Heater User Manual and Safety Instructions
Comprehensive guide to the Sealey IR15 Infrared Halogen Heater, covering safety, operation, specifications, assembly, and maintenance for optimal performance and safe use.