Leviton 8215-PLC

Leviton 8215-PLC Hospital Grade Plug Instruction Manual

Model: 8215-PLC

مقدمة

The Leviton 8215-PLC is a 15 Amp, 125 Volt, NEMA 5-15P, 2-pole, 3-wire, straight blade grounding plug designed for hospital grade applications. This transparent plug features a power indication LED, allowing for visual confirmation of power presence. Constructed with a super tough nylon body and solid brass blades and contacts, it offers durability, superior conductivity, and resistance to impact, abrasion, and chemicals.

Leviton 8215-PLC Hospital Grade Plug

Image: The Leviton 8215-PLC Hospital Grade Plug, transparent with a green power indicator.

معلومات السلامة

تحذير: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

الإعداد والتثبيت

This section provides instructions for properly wiring the Leviton 8215-PLC plug to a power cord. Ensure the power cord is appropriate for the intended application and current rating.

الأدوات المطلوبة:

تعليمات الأسلاك:

  1. جهّز الحبل: Carefully strip the outer jacket of your power cord to expose approximately 1.5 to 2 inches of the insulated wires (typically black, white, and green/bare copper). Then, strip about 1/2 inch of insulation from the ends of the black (hot), white (neutral), and green/bare copper (ground) wires.
  2. فك القابس: Unscrew the assembly screws on the plug body to separate the front and back sections. Slide the back cover and cord clamp components onto the power cord in the correct orientation.
  3. ربط الأسلاك: The Leviton 8215-PLC features internal wiring chambers designed to isolate individual conductors. Connect the wires to the appropriate terminals:
    • Green/Bare Copper Wire: الاتصال بـ أخضر (grounding) screw terminal.
    • سلك أبيض: الاتصال بـ فضي (neutral) screw terminal.
    • السلك الأسود: الاتصال بـ نحاس (hot) screw terminal.
    Ensure all wire strands are securely under the screw heads and tightened firmly. Trim any excess wire strands to prevent short circuits.
  4. Secure the Cord Clamp: Position the cord clamp around the power cord and tighten the screws to provide a secure grip without damaging the cord's outer jacket. This prevents strain on the wire connections.
  5. أعد تجميع القابس: Carefully align the front and back sections of the plug, ensuring no wires are pinched. Securely fasten the assembly screws.
Internal wiring chambers of the plug

الصورة: عن قرب view of the internal wiring chambers, showing isolated conductors and screw terminals.

Plug with cord clamp securing a cable

Image: The plug's cord clamp mechanism, designed to secure the power cord and prevent strain.

تعليمات التشغيل

Once properly wired, the Leviton 8215-PLC plug is ready for use.

  1. الاتصال بالطاقة: Insert the plug firmly into a compatible 125V, 15A NEMA 5-15R receptacle.
  2. Verify Power Indication: The long-life LED bulb on the transparent body of the plug will illuminate green when power is present at the device. This provides a quick visual confirmation that the circuit is live and the plug is receiving power.
  3. قطع الاتصال: To disconnect, grasp the plug body firmly and pull it straight out from the receptacle. Do not pull by the cord.

صيانة

Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 8215-PLC plug.

استكشاف الأخطاء وإصلاحها

If you encounter issues with your Leviton 8215-PLC plug, refer to the following troubleshooting steps:

تحديد

رقم الموديل 8215-PLC
Ampإيراج 15 Amps
المجلدtage 125 فولت
تكوين نيما 5-15ص
أعمدة / أسلاك 2 Pole, 3 Wire Grounding
درجة المنتج درجة المستشفى
مادة Super Tough Nylon (Body), Thermoplastic (Back Cover)
لون شفاف
مؤشر الطاقة لمبة LED
الموافقات UL 498، CSA C22.2، NOM 057
وزن العنصر 0.01 أونصات
أبعاد المنتج 9.38 × 7.13 × 9 بوصة

معلومات الضمان

This Leviton product is covered by the manufacturer's limited lifetime warranty. For detailed information regarding warranty terms, conditions, and registration, please refer to the official Leviton website or contact Leviton customer service directly. Keep your proof of purchase for warranty claims.

دعم العملاء

For technical assistance, product inquiries, or further support, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the Leviton webتغليف الموقع أو المنتج.

ليفيتون Webموقع: www.leviton.com

المستندات ذات الصلة - 8215-PLC

قبلview دليل اختيار مفاتيح Leviton التجارية والصناعية
دليل اختيار شامل من Leviton يوضح بالتفصيل مفاتيح الدرجة التجارية والصناعية، بما في ذلك مفاتيح التبديل، ومفاتيح Decora Plus، ومفاتيح Lev-lok، ومفاتيح مضادة للميكروبات، وأنواع المفاتيح المتخصصة مع تفاصيل التطبيق ومخططات الأسلاك.
قبلview دليل تركيب واختبار مقبس GFCI من Leviton
دليل شامل حول كيفية تثبيت واختبار مقبس GFCI من نوع Leviton SmartLock Pro، بما في ذلك تعليمات الأسلاك، واحتياطات السلامة، ونصائح استكشاف الأخطاء وإصلاحها.
قبلview ليفيتون EV40P EV سلسلة 40 AMP دليل تركيب الشاحن القابل للتوصيل
دليل التثبيت لـ Leviton EV40P EV Series 40 AMP شاحن سيارة كهربائية. يتضمن تحذيرات السلامة، والمواصفات، وخطوات التركيب، وإجراءات التشغيل، واستخدام بطاقة RFID، ورسائل الخطأ، والصيانة، ومعلومات الضمان.
قبلview دليل تركيب وتشغيل منفذ GFCI من Leviton مع منافذ USB
دليل شامل لتثبيت وتشغيل منافذ Leviton GFCI مع منافذ USB، بما في ذلك تعليمات الأسلاك، وتحذيرات السلامة، وإجراءات الاختبار، ومعلومات الضمان.
قبلview تركيب واختبار مقبس Leviton الذكي المزود بقاطع دائرة الحماية من التسرب الأرضي: دليل شامل
تعليمات خطوة بخطوة لتركيب واختبار منافذ Leviton Smart GFCI (طرازات D2GF1 وD2GF2). تعرّف على وظائف GFCI، والتوصيلات الكهربائية، واستكشاف الأعطال وإصلاحها، واحتياطات السلامة.
قبلview تعليمات تركيب حاوية مركز التحميل من Leviton
تعليمات تركيب مفصلة لصناديق مركز التحميل من Leviton، موديلات LP2xx وLP3xx وLP4xx وLP6xx. تشمل هذه التعليمات السلامة، وإزالة القطع، والتركيب، والأسلاك، وتركيب قاطع الدائرة الفرعية، وتركيب الغطاء.