1. المقدمة
This instruction manual provides essential information for the proper installation, handling, and maintenance of your Eheim AEH7433710 Ceramic Axle Set. This set is a genuine replacement part designed for Eheim Classic external filter models 2211 and 2213, ensuring optimal performance and longevity of your aquarium filtration system. Please read these instructions carefully before proceeding with installation.

2. دليل التثبيت
The ceramic axle is a critical component of your filter's impeller assembly. Proper installation is vital for the filter's quiet operation and efficient water flow. Always refer to your specific Eheim Classic filter's main instruction manual for detailed disassembly and reassembly procedures.
2.1. الأدوات المطلوبة
- قطعة قماش نظيفة
- Small container for removed parts (optional)
2.2. التثبيت خطوة بخطوة
- تحضير: Disconnect the filter from the power supply and turn off any associated aquarium equipment. Close the inlet and outlet valves to prevent water leakage.
- التفكيك: Carefully disconnect the hoses and remove the filter head from the filter canister. Place the filter head on a clean, stable surface.
- Access Impeller Chamber: Open the impeller cover on the filter head. This usually involves unlatching or unscrewing a cap.
- إزالة المكونات القديمة: Gently remove the impeller. The old ceramic axle and rubber bushings (if present) should also be removed. Inspect the impeller for any damage or wear; replace if necessary.
- Install New Axle: Insert the new ceramic axle into the center of the impeller. Ensure it sits securely.
- Install Bushings: Place the new rubber bushings (included in the set) into their designated slots within the impeller chamber, typically at each end where the axle rests.
- Reassemble Impeller: Carefully place the impeller with the new axle and bushings back into the impeller chamber. Ensure it rotates freely without obstruction.
- Close Filter Head: Securely reattach the impeller cover. Reassemble the filter head onto the canister, ensuring all seals are correctly seated.
- Restart Filter: Reconnect the hoses, open the inlet and outlet valves, and plug the filter back into the power supply. Prime the filter according to your filter model's instructions if necessary.

3. Post-Installation Operation
After successful installation, your Eheim Classic filter should resume normal operation. Observe the filter for the first few hours to ensure proper function.
- تدفق المياه: Verify that water is flowing through the filter at the expected rate.
- مستوى الضوضاء: Listen for any unusual noises, such as grinding or rattling, which could indicate improper seating of the impeller or axle.
- تسرب: Check all connections and seals for any signs of water leakage.
4. الرعاية والتعامل
The Eheim ceramic axle is durable in its intended use but is inherently fragile due to its material composition. Proper handling is crucial to prevent damage.
- التعامل اللطيف: Always handle the ceramic axle with care. Avoid dropping it or subjecting it to sudden impacts.
- تنظيف: When cleaning the impeller chamber, remove the axle and impeller gently. Clean them with a soft brush and rinse with clean water. Do not use harsh chemicals or abrasive materials.
- تقتيش: Regularly inspect the ceramic axle for any signs of cracks, chips, or wear. A damaged axle can lead to increased noise, reduced filter performance, or complete filter failure.
- تخزين: If storing a spare axle, keep it in its original protective packaging in a safe place to prevent accidental damage.
5. استكشاف الأخطاء وإصلاحها
If you encounter issues after replacing the ceramic axle, consult the following common troubleshooting steps:
5.1. Filter Not Starting or Making Unusual Noise
- السبب المحتمل: The ceramic axle or impeller is not seated correctly, or the axle is damaged.
- حل: Disconnect power, disassemble the filter head, and carefully re-inspect the impeller and axle installation. Ensure the axle is fully inserted into the impeller and that both ends are properly seated in the rubber bushings. Check the axle for any visible cracks or breaks.
5.2. Reduced Water Flow
- السبب المحتمل: Obstruction in the impeller chamber, or the impeller is not rotating efficiently due to axle damage or wear.
- حل: Disconnect power, clean the impeller and impeller chamber thoroughly. Verify that the ceramic axle is intact and not worn down, which could cause the impeller to wobble or drag.
6. مواصفات المنتج
| ميزة | التفاصيل |
|---|---|
| ماركة | إهايم |
| Model Number (Axle Set) | AEH7433710 |
| Compatible Filter Models | Eheim Classic 2211, 2213 (also compatible with 2048, 2448, 2313) |
| مادة | سيراميك |
| وشملت المكونات | 1x Ceramic Impeller Shaft, 2x Rubber Bushings |
| وزن العنصر | 4.54 جرام (0.16 أونصة) |
| أبعاد المنتج (تقريبًا) | 1 × 1 × 1 بوصة |
| رمز المنتج الموحد | 720686741966 |
| رقم قطعة الشركة المصنعة | 207146 |
7. معلومات الضمان
Warranty coverage for Eheim replacement parts is typically provided by the manufacturer. Please retain your proof of purchase. For specific warranty terms and conditions, refer to the documentation included with your original Eheim filter unit or visit the official Eheim webموقع.
ملحوظة: Damage resulting from improper handling, installation, or misuse is generally not covered under warranty.
8. دعم العملاء
For further assistance, technical support, or inquiries regarding your Eheim product, please contact Eheim directly through their official channels.
- Official Eheim Webموقع: www.eheim.de
- Refer to the Eheim webموقع إلكتروني يحتوي على معلومات الاتصال، والأسئلة الشائعة، وموارد إضافية عن المنتج.