The Symptoms related to an incorrectly installed Float Valve are as follows;

  • Water reservoir will not fill using float valve system
  • Water reservoir overfills using float valve system
  • Water reservoir underfills using float valve system

تحذير:
DISCONNECT THE EVAPORATIVE COOLER FROM THE POWER
SOURCE PRIOR TO ANY MAINTENANCE PERFORMED

Float Valve Replacement Instructions

  1. Disconnect your shop water supply hose from the float valve inlet.
    TQB 1027T Evaporative Cooler - fig 1
  2. Disconnect the evaporative cooler from the power source.
    TQB 1027T Evaporative Cooler - fig 2
  3. Remove cooling pad fastening sheet [item 27] then remove dust proof sheet [item 26] and cooling pad [item 25] by removing the Phillips head screws.
    TQB 1027T Evaporative Cooler - fig 3
  4. Use a water supply hose to manually fill the reservoir to the full level on the level indicator panel located at the rear of the unit below the air inlet panels, or if overfilled drain off the excess water to the correct full level.
    TQB 1027T Evaporative Cooler - fig 4
  5. Reconnect the water supply to the float valve inlet and turn the supply on.
  6. With the water supply turned on, water will flow from the float valve, Use the float arm adjustor to set the off position by tilting the float downwards and tightening the adjuster knob, repeat this adjustment until the float bottom is under water and the water flow has ceased. This will be at an angle of approximately 15 to 20 degrees to the body of the valve.
    TQB 1027T Evaporative Cooler - fig 5 
  7. Once the float valve angle has been set and the water is not flowing, we recommend you open the reservoir drain and wait for the float valve to open and filling begins, then close the drain, and check the level at which the water flow stops. If it stops below or above the level mark as seen in instruction 4. Then readjust the float angle either up to increase volume, or down to reduce volume and prevent overflow.
  8. Reassemble cooling pad, dust proof sheet and cooling pad fastening sheet.
  9. Reconnect the electricity supply and turn to on position.

At this point the Evaporative Cooler should be ready for Operation.
If the Evaporative Cooler continues to show the Symptoms as above, please refer to a Qualified Service Technician or contact TQB Brands via sales@tqbbrands.com.au أو 03 9357 8440.

رسم تخطيطي للأجزاء

TQB 1027T Evaporative Cooler - fig 6قائمة قطع غيار

الجزء # وصف المنتج الكمية الجزء # وصف المنتج الكمية
1 Control Panel & Label 1 17 العجلة الأمامية 2
2 لوحة العرض 1 18 استنزاف صمام 1
3 مجلس PC 1 19 الأنابيب Clamp 3
4 المكثف (مكثف التشغيل) 1 20 أنابيب المياه 1
5 Automatic Diffuser 1 21 مروحة 1
6 Cooling Casting 1 22 محرك المروحة 1
7 Front Mesh 1 23 موزع المياه 1
8 بكرة اسلاك 2 24 قوس مروحة 4
9 Water Level Displayer 1 25 لوحة التبريد 1
10 فتحة مدخل المياه 1 26 شبكة الغبار 1
11 حلقة الأسلاك 3 27 Cooling Pad Fasten Sheet 1
12 سلك كهربائي 1 28 مضخة الماء 1
13 Water Level Sensor Fixture 1 29 مقطع غير القابل للصدأ 2
14 مستشعر مستوى الماء 1 30 Water Pump Platen 1
15 خزان المياه 1 31 تطفو 1
16 العجلة الخلفية 2 32 جهاز التحكم 1

MN December22