دليل مالك POTTER PSN-1000 Power Expander

ميزات دليل مالك POTTER PSN-1000 Power Expander 10 Amp مصدر الطاقة 3 Amps ، منظم حسب NAC 6 NACs Class B أو 3 NACs Class A 2 مدخلات ملامسة جافة قابلة للبرمجة والمراقبة بالكامل من خلال لوحة التحكم اتصال مكرر P-Link معزول ، الفئة A أو B ما يصل إلى 31 مصدر طاقة لكل لوحة تحكم مع نظام واسع ...

دليل المالك لـ POTTER RLY-5 Relay Expander

POTTER RLY-5 Relay Expander Features Mounts with included stacker bracket Provides 5 user configurable relays Contact Rating of 24VDC / 3.0A, 125 VAC / 3.0A (resistive) Maximum 31 RLY-5s per panel Maximum P-Link wire length of 6,500 feet. Product includes a 5 year warranty UUKL Listed for Smoke Control Description The RLY-5 is a relay …

دليل المالك لـ POTTER ALE-127 Loop Expander

POTTER ALE-127 Addressable Loop Expander Owner’s Manual Features Standby Current 80 mA Alarm Current 80 mA Ambient Operating Tem 0°C–49°C (32°F–120°F) Addressing Rotary Dial Compatible Panel PFC-8500 Description The ALE-127 is microprocessor based circuit assembly that provides an additional signaling line circuit (SLC) to the Potter PFC-8500. The SLC is power limited and supervised. The …

متوسع POTTER CA-6075 Class A دليل المالك

POTTER CA-6075 Class A Expander Description The CA-6075 is a Class A Expander. The CA-6075 allows for Class A wiring of the built in SLC circuit, P-Link communication bus and two (2) built in NAC circuits. The CA-6075 mounts to the provided framework in the fire alarm control panel. The Class A operation can be …

متوسع POTTER CA-6500 Class A دليل المالك

POTTER CA-6500 Class A Expander Features Provides Class A connection for NACs, P-Link and SLC Mounts to framework inside panel enclosure Allows for independent circuit selection of Class A operation Product includes a 5 year warranty UUKL Listed for Smoke Control Description The CA-6500 Class A expander allows six notification circuits, two PLINK circuits and …

دليل التعليمات المتوسع بوتر CA-4064 الفئة أ

POTTER CA-4064 Class A Expander NOTICE TO THE INSTALLER This manual provides an overview and the installation instructions for the CA-4064 module.All terminals are power limited and should be wired in accordance with the requirements of NFPA 70 (NEC) and NFPA 72 (National Fire Alarm Code). Failure to follow the wiring diagrams in the following …

POTTER FFT-EXP دليل تعليمات هاتف مكافحة الحرائق

POTTER FFT-EXP Fire Fighters Telephone Expander Instruction Manual NOTICE TO THE INSTALLER This manual provides an overview and the installation instructions for the FFT-EXP module. All terminals are power limited and should be wired in accordance with the requirements of NFPA 70 (NEC) and NFPA 72 (National Fire Alarm Code). Failure to follow the wiring …

POTTER IDC-6 دليل التعليمات لموسع دائرة جهاز بدء التشغيل

POTTER IDC-6 Initiating Device Circuit Expander  NOTICE TO THE INSTALLER This manual provides an overview and the installation instructions for the IDC-6 module. All terminals are power limited and should be wired in accordance with the requirements of NFPA 70 (NEC) and NFPA 72 (National Fire Alarm Code). Failure to follow the wiring diagrams in …

دليل تعليمات أداة توسيع الحلقة القابلة للعنونة POTTER PAD100-SLCE

POTTER PAD100-SLCE Addressable Loop Expander Instruction Installation Manual PAD100-SLCE Addressable Loop Expander NOTICE TO THE INSTALLER This manual provides an overview and the installation instructions for the PAD100-SLCE module. This module is only compatible with addressable fire systems that utilize the PAD Addressable Protocol. All terminals are power limited and should be wired in accordance …

دليل التعليمات لموسع الطاقة بوتر PSN1000 و PSN 1000E

POTTER PSN1000 and PSN 1000E Power Expander Instruction Manual Installation Wiring Document Primary AC  20VAC 50Hz~60Hz, 5.1 AMP كشف الحد الأدنى للتيار المتردد 98VAC 240VAC 50 هرتز ~ 60 هرتز ، 2 AMP Min Low AC Detect 194VAC Common Relays  3A @ 125VAC (Resistive) 3A @ 30VDC (Resistive) Battery Charging  27.3VDC @ 1A Low Battery Detect @20.4VDC Earth Fault to Any …