EARU EARU-1006
EARU Electric Single Phase Energy Meter 220V 80A Instruction Manual
Model: EARU-1006
1. المقدمة
The EARU Electric Single Phase Energy Meter (Model EARU-1006) is designed for accurate monitoring of electrical parameters in single-phase 220V, 80A systems. It provides real-time data for voltage (V), current (A), power (W), power factor (PF), frequency (Hz), and kilowatt-hour (kWh) consumption. This device assists in understanding energy usage and identifying potential inefficiencies in your electrical system.
2. معلومات السلامة
- يجب أن يتم التركيب بواسطة كهربائي مؤهل وفقًا لقوانين ولوائح الكهرباء المحلية.
- Ensure the main power supply is disconnected before installation or maintenance to prevent electric shock.
- لا تقم بتشغيل الجهاز إذا كان يبدو تالفًا.
- هذا الجهاز مصمم للاستخدام الداخلي في بيئة جافة. تجنب تعريضه للرطوبة أو درجات الحرارة القصوى.
- The maximum current rating is 80A. Do not exceed this limit.
3. انتهى المنتجview
The EARU-1006 energy meter features a clear LCD display that shows various electrical parameters simultaneously. It is designed for DIN rail mounting, allowing for easy integration into standard electrical distribution boards.

الشكل 1: الجبهة view of the EARU Electric Single Phase Energy Meter, showing the LCD display with various electrical readings.

الشكل 2: مفصل view of the LCD display, illustrating the layout of voltage, current, power, frequency, power factor, and kWh readings.
4. محتويات العبوة
تتضمن الحزمة عادةً ما يلي:
- 1 x EARU Electric Single Phase Energy Meter (Model EARU-1006)
5. المواصفات

Figure 3: Technical data table providing detailed specifications of the energy meter.
| المعلمة | قيمة |
|---|---|
| ماركة | إيرو |
| نموذج | EARU-1006 |
| تصنيف المجلدtage | AC110V/220V (230 Volts) |
| التيار المقدر | 80 أمبير |
| تكرار | 50/60 هرتز |
| دقة القياس | ±1% / Class 1 |
| استهلاك الطاقة | <2 واط |
| تثبيت | 35 ملم DIN السكك الحديدية |
| درجة حرارة العمل | من -10 درجة مئوية إلى +55 درجة مئوية |
| درجة حرارة التخزين | من -40 درجة مئوية إلى +70 درجة مئوية |
| رطوبة العمل | 5% إلى 95% رطوبة نسبية |
| نوع العرض | شاشة الكريستال السائل |
| Max kWh Record | 999999 كيلو وات في الساعة |
| أبعاد المنتج | 10 × 5 × 10 سم |
| وزن العنصر | 450 جرام |

Figure 4: Dimensional drawing of the energy meter, showing measurements in both millimeters and inches.
6. الإعداد والتثبيت
مهم: تأكد من فصل جميع الطاقة قبل متابعة التثبيت.
- التركيب: The EARU-1006 is designed for 35mm DIN rail mounting. Snap the meter onto the DIN rail securely within your electrical panel.
- التوصيلات الكهربائية: Refer to the wiring diagram below for correct connection. This is a single-phase, 2-wire direct connection meter.
- Connect the Live (L) input wire to the designated 'L In' terminal.
- Connect the Neutral (N) input wire to the designated 'N In' terminal.
- Connect the Live (L) output wire to the designated 'L Out' terminal.
- Connect the Neutral (N) output wire to the designated 'N Out' terminal.
- تشغيل الطاقة: Once all connections are secure and verified, restore power to the circuit. The LCD display should illuminate and begin showing readings.

Figure 5: Wiring diagram illustrating the correct connections for the single-phase energy meter.
7. تعليمات التشغيل
The energy meter operates automatically once powered on. The LCD display continuously cycles through or shows multiple parameters simultaneously.
- Reading Parameters: The display shows Voltage (V), Current (A), Power (W), Power Factor (PF), Frequency (Hz), and Kilowatt-hour (kWh).
- kWh Reading: The meter records total kWh consumption. This reading is permanent and accumulates over time.
- إعادة ضبط كيلوواط ساعة: The meter features a manual reset function for the kWh reading. Consult the device's physical buttons or specific instructions on the meter itself for the reset procedure. Typically, a long press on a designated button (if present) will reset the temporary kWh value. The total kWh value is usually non-resettable.
8. الصيانة
- تنظيف: استخدم قطعة قماش ناعمة وجافة لتنظيف الجزء الخارجي من العداد. لا تستخدم المنظفات الكاشطة أو المذيبات.
- تقتيش: Periodically inspect the wiring connections to ensure they are tight and free from corrosion.
- بيئة: تأكد من أن بيئة التشغيل تظل ضمن نطاقات درجة الحرارة والرطوبة المحددة.
9. استكشاف الأخطاء وإصلاحها
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| العرض فارغ | لا يوجد مصدر طاقة؛ توصيلات كهربائية غير صحيحة | Check power connections and ensure power is supplied. Verify wiring against the diagram. |
| قراءات غير صحيحة | Incorrect wiring; Faulty connection | Double-check all wiring connections. Ensure wires are securely fastened. |
| kWh not accumulating | No load connected; Meter malfunction | Ensure there is an active electrical load connected through the meter. If problem persists, contact support. |
10. الضمان والدعم
The EARU Electric Single Phase Energy Meter (Model EARU-1006) typically comes with a 1-year warranty from the date of purchase. Please retain your purchase receipt for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Refer to the product packaging or manufacturer's webموقع للحصول على تفاصيل الاتصال.