مقدمة
This manual provides essential information for the safe and efficient operation, setup, and maintenance of your GÜDE 50140 Airpower 375/8/100 ED-SILENT oil-free piston compressor. Please read these instructions carefully before using the compressor to ensure proper function and to prevent injury or damage.
The GÜDE Airpower 375/8/100 ED-Silent is designed for various compressed air applications in a workshop environment. It features a powerful, oil-free, 4-cylinder motor and SuperSilent technology for quiet operation, with a sound pressure level of only 61 dB(A). The 100-liter steel tank provides ample air reserves, and the digital pressure reducer with an hour meter allows for precise pressure adjustment and monitoring.
تعليمات السلامة
يجب عليك دائمًا مراعاة احتياطات السلامة التالية لتقليل خطر الإصابة أو الضرر:
- اقرأ الدليل كاملا: Familiarize yourself with the compressor's controls and operation before use.
- السلامة الكهربائية: Ensure the power supply matches the compressor's requirements (230 Volts). Do not operate with damaged cords or plugs.
- منطقة العمل: Keep the work area clean, well-lit, and free from obstructions. Do not operate in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
- معدات الحماية الشخصية (PPE): Wear appropriate eye protection, hearing protection, and other safety gear as required by the task.
- سلامة الضغط: Never exceed the maximum operating pressure of 8 bar. The integrated safety valve is a critical component; do not tampمعها.
- صيانة: Disconnect the compressor from the power supply before performing any maintenance or adjustments.
- الأطفال والمتفرجون: أبقِ الأطفال والمارة بعيدًا عن ضاغط التشغيل.
- تصريف المكثفات: Regularly drain condensate from the air tank to prevent corrosion and ensure optimal performance.
- مواصلات: Use the transport handle and wheels for moving the compressor. Ensure it is stable before operation.
المنتج انتهىview
The GÜDE 50140 Airpower compressor is designed for ease of use and durability. Below are key components and features.

الشكل 1: ممتلىء view of the GÜDE 50140 Airpower 375/8/100 ED-SILENT compressor, showcasing its blue tank, motor units, handle, and wheels.

الشكل 2: The compressor with its overall dimensions: 87 cm (length), 51 cm (width), and 81 cm (height).
المكونات الرئيسية:
- Digital Pressure Reducer with Hour Meter: Allows precise adjustment of working pressure and displays boiler pressure, set pressure, and operating hours.
- Oil-Free 4-Cylinder Piston Motor: Provides powerful and maintenance-free operation.
- 100-Liter Steel Tank: Stores compressed air, reducing motor run time.
- مقبض النقل: لتسهيل المناورة.
- Stable Wheel Set and Swivel Castors: Enhances mobility.
- Two Compressed Air Connections: Enables simultaneous connection of two pneumatic tools.
- صمام الأمان: Essential safety feature to prevent over-pressurization.
- Condensate Drain Screw: Located at the bottom of the tank for draining accumulated moisture.

الشكل 3: Close-up of the digital control panel, showing displays for settings, pressure, tank pressure, and voltage, along with power buttons.

الشكل 4: Detail of the compressor's robust wheels and swivel castors, designed for easy movement and stability.

الشكل 5: View of internal connections and valves, including solenoid valves, which manage air flow and pressure within the compressor system.

الشكل 6: A comparative chart illustrating the low noise level of the GÜDE Airpower compressor (61 dB(A)) compared to other common sound sources.
يثبت
- فك التعبئة: أخرج الضاغط من عبوته بحرص. افحصه بحثًا عن أي ضرر ناتج عن الشحن.
- تجميع العجلة: Attach the stable wheel set and swivel castors if they are not pre-assembled. Ensure all fasteners are securely tightened.
- الموقع: Position the compressor on a firm, level surface in a well-ventilated area. Ensure there is adequate space around the unit for air circulation and maintenance.
- توصيل الطاقة: Connect the compressor to a grounded 230V power outlet. Ensure the power cord is not damaged or pinched.
- الفحص الأولي: Before first use, ensure the condensate drain screw is closed.
تعليمات التشغيل
- تشغيل الطاقة: Plug in the compressor. The digital display should illuminate. Press the power button to turn the unit on.
- ضبط ضغط التشغيل: Use the digital pressure reducer to set the desired working pressure. The display will show the current tank pressure and the set working pressure. The maximum pressure is 8 bar.
- Connect Air Tools: Attach your pneumatic tools to one or both of the two compressed air connections. Ensure connections are secure to prevent air leaks.
- عملية: The compressor will automatically start when the tank pressure drops below the set minimum and stop when it reaches the maximum set pressure.
- إيقاف التشغيل: After use, turn off the compressor using the power button and disconnect it from the power supply.
- أزال الضغط: Before storing, release any remaining air pressure from the tank by opening the drain valve or using an air tool until the tank is empty.
صيانة
Regular maintenance ensures the longevity and optimal performance of your compressor. Always disconnect the power before performing maintenance.
- تصريف المكثفات: Drain the condensate from the air tank daily or after each use. This prevents corrosion inside the tank. Place a suitable container under the drain screw and open it until all water is expelled. Close the screw tightly afterward.
- مرشحات الهواء: Periodically inspect the air filters (4 included). Clean or replace them if they are dirty or clogged to ensure proper air intake and prevent motor strain.
- تصميم خالٍ من الزيت: This compressor is oil-free, meaning no oil changes or oil level checks are required for the pump.
- النظافة العامة: Keep the exterior of the compressor clean. Wipe off dust and debris with a dry cloth. Do not use solvents or abrasive cleaners.
- التحقق من الاتصالات: Regularly check all air connections and fittings for leaks. Tighten if necessary.
استكشاف الأخطاء وإصلاحها
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| الضاغط لا يبدأ. | No power supply; power switch off; thermal overload. | Check power connection and outlet; ensure power switch is ON; allow motor to cool down if overloaded. |
| يعمل الضاغط بشكل مستمر أو متكرر. | Air leak in system; heavy air consumption; pressure switch malfunction. | Check all connections and hoses for leaks; reduce air consumption if possible; consult service if pressure switch is faulty. |
| انخفاض ضغط الهواء الخارج. | Air leak; clogged air filter; pressure reducer set too low. | Check for leaks; clean or replace air filter; adjust digital pressure reducer to desired setting. |
| ضجيج أو اهتزاز مفرط. | Loose components; compressor not on a level surface; internal issue. | Check and tighten any loose bolts or fittings; ensure stable placement; if problem persists, consult service. |
| الماء في مخرج الهواء. | Condensate not drained regularly. | Drain condensate from the tank immediately and regularly. |
تحديد
| ميزة | قيمة |
|---|---|
| رقم الموديل | 50140 |
| ماركة | GÜDE |
| قوة المحرك | 2.2 kW (2200 Watt) |
| المجلدtage | 230 فولت |
| عدد الاسطوانات | 4 |
| سعة الخزان | 100 لتر |
| الحد الأقصى للضغط | 8 بار |
| قوة الشفط | 375 لتر/دقيقة |
| Effective Quantity (0 bar) | 360 لتر/دقيقة |
| Effective Quantity (4 bar) | 234 لتر/دقيقة |
| Effective Quantity (7 bar) | 194 لتر/دقيقة |
| مستوى ضغط الصوت | 61 ديسيبل (أ) |
| الأبعاد (الطول × العرض × الارتفاع) | 87 × 51 × 81 سم |
| وزن | 70 كيلوغرام |
| ميزة خاصة | خالي من الزيوت |
| الاستخدام الموصى به | Tire inflation, general compressed air tasks |
الضمان والدعم
For warranty information, technical support, or spare parts, please refer to the documentation provided with your purchase or contact GÜDE customer service directly. Contact details can typically be found on the manufacturer's webالموقع أو على عبوة المنتج.
يرجى توفير رقم الطراز (50140) وتاريخ الشراء عند الاتصال بالدعم.