Prolink PRO901ES

Prolink PRO901ES 1000VA/900W Online UPS Instruction Manual

Model: PRO901ES

1. المقدمة

The Prolink PRO901ES is a 1000VA/900W Pure Sine Wave Online Uninterruptible Power Supply (UPS) designed to provide reliable power backup and protection for critical electronic equipment. This UPS features true double-conversion technology, ensuring a consistent and clean power supply. It is suitable for various applications including data centers, medical equipment, office workstations, ATMs, and kiosk machines.

Prolink PRO901ES 1000VA/900W Online UPS

Figure 1: Prolink PRO901ES 1000VA/900W Online UPS, Tower Type.

2. انتهى المنتجview

2.1 الميزات الرئيسية

  • True Double-Conversion Online Technology: Provides consistent, high-quality AC power regardless of input fluctuations.
  • إخراج موجة جيبية نقية: Ensures compatibility with sensitive electronic equipment.
  • High Input Power Factor Correction: Improves efficiency and reduces overall power losses.
  • Programmable Power Management Outlets: Allows for flexible control over connected devices.
  • Emergency Power Off (EPO) Function: Provides an immediate shutdown mechanism for safety.
  • المجلد المتقدمtagاللائحة (AVR): Regulates output voltage within 1% tolerance, protecting devices from voltage spikes or sags.
  • قدرات المراقبة: Status can be monitored via the LCD display or PC programs.

2.2 وصف اللوحة الخلفية

The rear panel of the PRO901ES UPS features essential connection ports for power input, output, and communication.

Rear panel of Prolink PRO901ES UPS with labeled ports

Figure 2: Rear Panel Layout of PRO901ES.

  1. مدخل التيار المتردد: Connects the UPS to the main power supply.
  2. قاطع دائرة الإدخال: Provides overcurrent protection for the input.
  3. منفذ اتصال USB: For connecting to a computer for monitoring and management.
  4. RS-232 Communication Port: Another port for computer communication.
  5. Intelligent Slot: For optional network management cards (e.g., SNMP).
  6. اتصال البطارية الخارجية: (Only available for 'L' models) For connecting external battery packs to extend runtime.
  7. منافذ الإخراج: Three universal sockets for connecting protected devices.
Diagram showing various applications of the UPS including ATM machines, server rooms, security systems, desktop PCs, and POS machines.

Figure 3: Typical applications for the Prolink PRO901ES UPS.

3. تعليمات الإعداد

Follow these steps for initial setup of your Prolink PRO901ES UPS:

  1. فك التعبئة: Carefully remove the UPS from its packaging and inspect for any damage. Retain packaging for future transport.
  2. الموقع: Place the UPS in a clean, dry, and well-ventilated area, away from direct sunlight or heat sources. Ensure adequate clearance for airflow.
  3. الشحن الأولي: Before connecting any devices, plug the UPS into a standard AC power outlet using the provided power cord. Allow the unit to charge for at least 8 hours to ensure optimal battery performance.
  4. توصيل الأجهزة: Once the UPS is fully charged, connect your critical electronic devices (e.g., computers, monitors, network equipment) to the output receptacles on the rear panel. Do not overload the UPS beyond its rated capacity (900W).
  5. إعداد الاتصال (اختياري): For advanced monitoring and management, connect the UPS to a computer using a USB or RS-232 cable. Install the necessary software (if provided) to enable communication features.
  6. تشغيل الطاقة: Press the power button on the front panel to turn on the UPS. The LCD display will illuminate, indicating the operational status.

4. تعليمات التشغيل

4.1 تشغيل/إيقاف التشغيل

  • لتشغيل: Press and hold the power button on the front panel until the UPS powers on.
  • لإيقاف التشغيل: Press and hold the power button until the UPS powers off. Ensure all connected devices are safely shut down before powering off the UPS.

4.2 فهم شاشة LCD

The front panel LCD provides real-time information about the UPS status, including input/output voltage, battery level, load percentage, and various operational modes.

Diagram showing the UPS LCD display and its various indicators for input, output, battery, and operational status.

Figure 4: Monitoring status from the LCD display.

4.3 إيقاف التشغيل في حالات الطوارئ (EPO)

The EPO function allows for an immediate and complete shutdown of the UPS and all connected equipment in an emergency. Refer to the detailed wiring diagram in the full user manual for proper EPO connection.

Diagram illustrating zero transfer time, preventing reboots or resets during power supply hold up time.

Figure 5: Zero transfer time ensures continuous operation during power events.

Diagram showing how the UPS provides clean power output, protecting against power failure, harmonic distortion, line noise, frequency variation, under voltagه ، أكثر من المجلدtage, power sag, and power surge.

Figure 6: The UPS provides clean power output, mitigating various power issues.

Diagram comparing a computer exposed to risk from voltage spike/surge (blue screen error) versus a computer protected by high-precision AVR (stable operation).

Figure 7: High-Precision AVR regulates output voltage within 1% tolerance.

5. الصيانة

  • العناية بالبطارية: The UPS uses Lead Acid batteries. To prolong battery life, avoid frequent deep discharges and operate the UPS within recommended temperature ranges. Periodically perform a battery self-test if available through the monitoring software.
  • تنظيف: Keep the UPS clean and free from dust. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners. Ensure ventilation openings are not blocked.
  • تخزين: If storing the UPS for an extended period, ensure it is fully charged and then recharge it every 3 months to prevent battery degradation.

6. استكشاف الأخطاء وإصلاحها

This section addresses common issues you might encounter with your UPS. For more complex problems, contact customer support.

  • جهاز UPS لا يعمل: Check if the AC input cable is securely connected and if the input circuit breaker has tripped. Ensure the battery is sufficiently charged.
  • مدة تشغيل البطارية قصيرة: This may indicate aging batteries or an overloaded UPS. Reduce the connected load or consider battery replacement if the unit is old.
  • ضجيج المروحة العالي: Some users have reported noticeable fan noise. While often normal for cooling, ensure the ventilation is not obstructed. If the noise is excessive or unusual, contact support.
  • الأجهزة المتصلة لا تتلقى الطاقة: Verify that the UPS is on and not in a fault state. Check the output receptacles and ensure devices are properly plugged in.

7. المواصفات

ميزةمواصفة
ماركةبرولينك
رقم الموديلPRO901-ES (USP-PRO901ES-3U)
سعة1000 فولت أمبير / 900 واط
تكوين خلية البطاريةحمض الرصاص
المجلدtage240 فولت
حجم الإخراجtage240 فولت (تيار متردد)
Ampإيراج7 Amps
عامل الشكلبرج
قوة التوصيل نوعالنوع ج
نوع الموصليو إس بي، RS-232
عدد المنافذ3 (Universal sockets)
مواد التغليفمعدن
لونأسود
التقى المواصفاتEN 62040-2:2006, CE
بلد المنشأالصين

8. الضمان والدعم

The Prolink PRO901ES UPS comes with a ضمان محلي لمدة عام واحد. For technical assistance or warranty claims, please refer to the contact information below.

Prolink Official Store information including Original product, Fast Delivery, Local Warranty & Technical Support, and 30 Years of Excellence.

Figure 8: Prolink Official Store information.

الدعم الفني:

Ask a question about this manual