SMARTGEN CMM366A-ET

SMARTGEN CMM366A-ET Cloud Monitoring Communication Module User Manual

Model: CMM366A-ET

1. المقدمة وما فوقview

The SMARTGEN CMM366A-ET Cloud Monitoring Communication Module is an Ethernet communication protocol switch module designed to connect gensets (with SCI) to the internet. After logging into a cloud server, the module receives the corresponding genset controller communication protocol. It acquires genset data via RS485, USB, LINK, or RS232 ports and transmits this data to the cloud server via wired Ethernet. This enables real-time monitoring of running status and access to historical records through mobile applications (iOS or Android) and PC terminal devices.

Beyond genset monitoring, the CMM366A-ET module also supports digital alarm input/output signals, allowing for monitoring of generator room access, theft prevention, and fire detection facilities.

أمام view of the CMM366A-ET module showing USB, Ethernet, and LINK ports

الشكل 1: الجبهة view of the CMM366A-ET module, highlighting the USB, Ethernet, and LINK communication ports.

واجهة بزاوية view of the CMM366A-ET module with side LED indicators

الشكل 2: الجبهة بزاوية view of the CMM366A-ET module, showing the communication ports and the row of LED indicators on the side.

2. الأداء والخصائص

  • Connects to a cloud server via wired ETHERNET for one-to-one monitoring.
  • Features multiple ports for communication with genset control modules: RS485, RS232, LINK, and USB (Host). Capable of monitoring a wide range of international first-class genset control modules.
  • Wide power supply range: DC (8~35)V, allowing direct use of the genset's built-in starter battery.
  • Equipped with an ARM-based 32-bit SCM for high hardware integration and strong programming capabilities.
  • Includes a GPS locate function to acquire location information and track the genset.
  • Utilizes JSON network data communication protocol, uploading real-time data variations with a compression algorithm to significantly reduce network traffic.
  • Immediately uploads data to the server when an alarm occurs.
  • Two auxiliary digital input ports are available for receiving external alarm signals.
  • One auxiliary relay output port can output various alarm signals.
  • Includes calendar and clock functions.
  • Power and multiple communication status indicators on the front panel provide clear operational status at a glance.
  • Features a lamp وظيفة الاختبار.
  • Parameters can be adjusted via the USB port.
  • Supports standard π-type 35mm guide-rail installation or screw-fixed installation, allowing flexible mounting within the genset control box.
  • Modular design with a self-extinguishing ABS plastic shell, offering light weight, compact structure, and easy installation.

3. المواصفات

The following table details the technical specifications of the CMM366A-ET module:

غرضمحتويات
حجم التشغيلtageتيار مستمر 8.0 فولت ~ 35.0 فولت ، مصدر طاقة مستمر
استهلاك الطاقةStandby: ≤2W, Working: ≤5W
المدخلات الرقميةمدخلات رقمية خالية من الفولت
مخرج التتابع1A تيار مستمر 30 فولت فولت الإخراج الحر
مضيف USBمنفذ أنثى USB من النوع A.
RS485نوع معزول
RS232النوع العام
وصلةمنفذ SmartGen الحصري
جهاز USBمنفذ أنثى USB من النوع B
ETHERNETواجهة شبكة RJ45 10/100Mbps ذاتية التكيف
أبعاد العلبة72.5 مم × 105 مم × 34 مم (تقريبًا 4.13 × 2.87 × 1.38 بوصات)
ظروف العملTemperature: (-25~+70)°C, Humidity: (20~93)%RH
حالة التخزيندرجة الحرارة: (-25 ~ + 70) درجة مئوية
وزن0.15kg (approx. 6.4 ounces)
مادةSelf-extinguishing ABS plastic

4. التثبيت والإعداد

4.1 التركيب

The CMM366A-ET module offers flexible installation options. It can be mounted using a standard π-type 35mm guide-rail (DIN rail) or via screw-fixed installation. This allows for convenient placement within a genset control box or other suitable enclosures.

خلف view of the CMM366A-ET module showing the orange DIN rail clip

الشكل 3: خلفي view of the CMM366A-ET module, illustrating the integrated orange clip for DIN rail mounting.

4.2 الأسلاك والتوصيلات

Proper wiring is essential for the correct operation of the CMM366A-ET module. Refer to the system diagram and terminal descriptions below for guidance.

CMM366A-ET System Diagram showing connections from Diesel Genset Controllers to CMM366A-ET, then to Router, Cloud Server, and finally to Cellphone, Pad, PC

Figure 4: CMM366A-ET System Diagram. This diagram illustrates how one CMM366A-ET module connects with one genset monitor module via RS485, LINK, RS232, or USB ports. The CMM366A-ET then connects to a router, which communicates with the cloud server, enabling monitoring via cellphone, tablet, or PC.

The CMM366A-ET module connects to a genset controller via one of its communication ports (RS485, LINK, RS232, or USB). It then connects to a network router via its Ethernet port. The router facilitates communication with the cloud server, allowing remote monitoring and control.

Refer to the following table for detailed terminal descriptions and recommended cable sizes:

Table 4 - Terminals Description from the user manual, detailing No., Function, Cable Size, and Note for each terminal

Figure 5: Terminal Descriptions. This table provides details for each terminal, including its number, function, recommended cable size, and specific notes for connection.

لا.وظيفةحجم الكابلملحوظة
1B-1.0 مم²متصل ببطارية سالبة لبدء التشغيل.
2B+1.0 مم²متصلة ببطارية موجبة لبدء التشغيل. يوصى باستخدام فتيل 3A.
3المدخلات الرقمية 11.0 مم²نشط عند الاتصال بـ B-.
4المدخلات الرقمية 21.0 مم²نشط عند الاتصال بـ B-.
5Relay Output (Normally Open)1.0 مم²Normally open output with 1A DC30V.
6Relay Output (Common)1.0 مم²
7Relay Output (Normally Close)1.0 مم²
8RS485 ب (-)0.5 مم²يوصى باستخدام سلك حماية بممانعة 120 أوم، وهو مؤرض من طرف واحد.
9RS485 أ (+)0.5 مم²
10إس سي آر0.5 مم²
11RS232 آر إكس0.5 مم²RS232
12RS232 تكساس0.5 مم²
13RS232 جي إن دي0.5 مم²

5. تعليمات التشغيل

5.1 Panel Indicators and Buttons

The front panel of the CMM366A-ET module features various LED indicators and a button to provide visual feedback on its operational status and for basic control functions.

Figure 1 - CMM366A-ET Front Panel Diagram showing labels for USB, RS485, Ethernet, LINK, RS232 ports and associated LED indicators

Figure 6: CMM366A-ET Front Panel Diagram. This diagram labels the various ports and their corresponding LED indicators for power, alarm, and communication status.

Refer to the following table for a description of each indicator:

رمزملحوظة
الطاقة / الإنذارGreen LED: Power supply normal indicator
Red LED: Common alarm indicator
RS485 (أحمر)إطفاء عادة: RS485 معطل
Normally Light: Communication normal
وميض: التواصل عادي
USB (أحمر)إطفاء عادة: USB (المضيف) معطل
Normally Light: Communication normal
وميض: التواصل عادي
ETHERNET (Red)Normally Extinguish: CMM366A-ET login with server unsuccessfully
Normally Light: Login with server successfully
وميض: الاتصال في الوقت الحقيقي عادي
LINK (Red)إطفاء عادة: معطل
Normally Light: Communication normal
وميض: التواصل عادي
RS232 (أحمر)إطفاء عادة: معطل
Normally Light: Communication normal
وميض: التواصل عادي
Lamp test/ResetPress this button for 1s, all the LEDs are illuminated; press for 10s, reset the module to default and all the LEDs blink for 3 times.
ملحوظة: بعد إعادة ضبط الوحدة، يجب إعادة تكوين المعلمات عبر برامج الكمبيوتر. يرجى العمل بحذر.

5.2 التشغيل الأساسي

Once the CMM366A-ET module is correctly installed and powered, it will automatically attempt to establish a connection with the configured cloud server via the Ethernet network. The status of this connection and other communication links can be observed through the front panel LED indicators.

  • يراقب: Real-time data and operational status of the genset can be monitored remotely using the dedicated mobile application (iOS or Android) or through a PC terminal connected to the cloud server.
  • تعديل المعلمة: If necessary, module parameters can be adjusted by connecting a PC to the USB port and using the appropriate PC software.
  • التعامل مع الإنذار: The module will immediately upload alarm data to the server upon detection of an alarm condition from connected digital inputs or the genset controller.

6. الصيانة

The CMM366A-ET module is designed for reliable operation with minimal maintenance. To ensure optimal performance and longevity:

  • حافظ على نظافة الوحدة وخلوها من الغبار والأوساخ. استخدم قطعة قماش ناعمة وجافة للتنظيف.
  • تأكد من وجود تهوية كافية حول الوحدة لمنع ارتفاع درجة الحرارة.
  • Periodically inspect all cable connections (power, communication, Ethernet) to ensure they are secure and free from damage.
  • Avoid exposing the module to extreme temperatures or humidity outside its specified operating conditions.
  • There are no user-serviceable parts inside the module. Do not attempt to open or repair the device yourself.

7. استكشاف الأخطاء وإصلاحها

If you encounter issues with your CMM366A-ET module, refer to the following troubleshooting guide:

  • No Power / All Indicators Off:
    Check the DC power supply (8~35V) connected to terminals B- and B+. Ensure the power source is active and the wiring is correct. Verify any inline fuses (3A recommended for B+).
  • Ethernet Communication Issues (ETHERNET LED off or blinking):
    Verify the Ethernet cable connection to both the module and the router. Ensure the router is powered on and has an active internet connection. Check network settings and ensure the module is correctly configured to access the cloud server. If the ETHERNET LED is off, it indicates an unsuccessful login to the server.
  • Genset Communication Issues (RS485, USB, LINK, RS232 LEDs off or blinking):
    Check the physical connections between the CMM366A-ET module and the genset controller for the respective communication port. Ensure the genset controller is powered and functioning correctly. If an LED is off, the corresponding port might be disabled or not communicating.
  • Alarm Indication (Red ALARM LED is lit):
    This indicates a common alarm condition. Check the connected auxiliary digital input ports for external alarm signals. Refer to your genset controller's manual for specific alarm codes or conditions.
  • Module Unresponsive / Unexpected Behavior:
    You can perform a reset to factory default parameters. Press and hold the Lamp test/Reset button for 10 seconds. All LEDs will blink three times to confirm the reset. تحذير: After a factory reset, all parameters will revert to their default settings and must be re-configured using PC software. Proceed with caution.

8. الضمان والدعم

Specific warranty information for the SMARTGEN CMM366A-ET module is not provided in this manual. Please refer to the product packaging, purchase documentation, or contact your vendor or SMARTGEN customer service for detailed warranty terms and conditions.

For technical support, assistance with installation, or troubleshooting beyond the scope of this manual, please contact SMARTGEN customer support or your authorized distributor. Ensure you have your product model number (CMM366A-ET) and any relevant purchase details available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.