Zerone Zer onekda4y0nmoz

Zerone External S Meter SWR Power Meter User Manual

Model: Zer onekda4y0nmoz

Brand: Zerone

مقدمة

This user manual provides comprehensive instructions for the Zerone External S Meter SWR Power Meter, designed specifically for use with Yae FT-857D and FT-897 transceivers. This high-performance meter offers excellent durability and stability, clearly displaying critical parameters such as automatic level control voltage, modulation level, standing wave ratio, and supply voltage.

  • Only applicable for Yae FT-857D and FT-897.
  • Clearly displays the automatic level control voltage, modulation level, standing ratio, and supply voltage.
  • High performance and super stability.
  • سهل التشغيل.
  • High quality and excellent durability.

الإعداد والمعايرة

Receive Display Settings

To configure the meter for receive display:

  1. اضغط على (العاملين) key to enter the setup menu and enable the extended menu.
  2. تناوب (يختار) to call up setup menu item No-061 (MTR ARX SEL).
  3. تناوب (DIAL) to select an external instrument display option from the following:
    • -سيج
    • -CTR
    • -VLT
    • -N / A
    • -FS: Buckle in the instrument 1mA full scale output calibration standard external instruments.
    • -عن
  4. يضعط (العاملين) to save the settings and exit the setup menu.

Emission Display Settings

To configure the meter for emission display:

  1. اضغط على (العاملين) key to enter the setup menu and enable the extended menu.
  2. تناوب (يختار) to call up setup menu item No-061 (MTR ARX SEL).
  3. تناوب (DIAL) to select an external instrument display option from the following:
    • -PWR
    • -ALC
    • -عصري
    • -SWR
    • -VLT
    • -N / A
    • -عن

طريقة المعايرة

To calibrate the meter for accurate readings:

  1. اضغط على (العاملين) key to enter the setup menu and enable the extended menu.
  2. تناوب (يختار) to call up setup menu item No-060 (MTR ARX SEL).
  3. تناوب (DIAL) للاختيار FS.
  4. Using a small flathead screwdriver, adjust the calibration adjustment hole at the rear of the unit until the meter pointer reaches full scale.
  5. المعايرة كاملة.
Zerone External S Meter with cable

Figure 1: The Zerone External S Meter with its connecting cable.

Close-up of Zerone S Meter display face

الشكل 2: تفصيلي view of the meter's display face, showing SIG, PWR, SWR, MOD, VOLT, and DISC scales.

تشغيل العداد

Once properly set up and calibrated, the Zerone External S Meter provides real-time readings for various radio parameters. The meter's needle will indicate values on the selected scale (SIG, PWR, SWR, MOD, VOLT, DISC) based on your radio's operation mode (receive or transmit).

Refer to your Yaesu FT-857D or FT-897 transceiver's manual for specific interpretations of these readings in different operating scenarios.

Zerone S Meter displaying various parameters

Figure 3: The meter clearly displays automatic level control voltage, modulation level, standing wave ratio, and supply voltage.

صيانة

The Zerone External S Meter is designed for durability. Regular maintenance is minimal but important for continued accuracy and longevity.

  • Keep the meter clean and free from dust. Use a soft, dry cloth to wipe the casing and display face.
  • تجنب تعريض العداد لدرجات حرارة قصوى أو لأشعة الشمس المباشرة لفترات طويلة.
  • If the meter's pointer does not return to zero when the unit is off or disconnected, it may be due to transit bumps. In such cases, carefully adjust the self-zeroing screw located on the mask-side of the instrument. This screw is typically black.
Zerone S Meter with dimensions

Figure 4: Dimensions of the Zerone External S Meter: 6.7 cm * 7 cm * 6 cm.

استكشاف الأخطاء وإصلاحها

This section addresses common issues you might encounter with your Zerone External S Meter.

Hidden Menu Access

If you are unable to find menu items No-060 or No-061 in your radio's setup menu, these menus might be hidden. To access them:

  1. اضغط لفترة طويلة على F key on your radio to open the menu settings.
  2. Set the relevant menu option to ON to reveal the hidden menus.
  3. اضغط على F key again to exit and save the settings.

Static Pointer / Zeroing Issues

The instrument is calibrated at delivery. However, transit bumps can sometimes cause the pointer to not rest at zero. If this occurs:

  • Locate the black self-zeroing screw on the mask-side of the instrument.
  • Gently adjust this screw with a small flathead screwdriver until the pointer rests at the zero mark.

تحديد

ميزةالتفاصيل
ماركةزيرون
رقم الموديلZer onekda4y0nmoz
أجهزة الراديو المتوافقةYaesu FT-857D, FT-897
وزن العنصر10.2 أونصة (0.29 كجم)
حجم الشاشة3.5 بوصة
بلد المنشأالصين
رمز المنتج الموحد745781109282
متوفر أولاً12 أغسطس 2019

معلومات الضمان

Specific warranty details for the Zerone External S Meter are not provided in this manual. Please refer to the product packaging or contact Zerone customer support for information regarding warranty coverage and terms.

دعم العملاء

For technical assistance, troubleshooting, or general inquiries about your Zerone External S Meter, please visit the official Zerone store or contact their customer service department. Contact information can typically be found on the product packaging or the manufacturer's official webموقع.

يمكنك أيضًا زيارة متجر زيرون على أمازون لمزيد من المعلومات حول المنتج وموارد الدعم.

© ٢٠٢٣ زيرون. جميع الحقوق محفوظة.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.