UMLIFE W3001
UMLIFE XH-W3001 Digital LED Temperature Controller Module User Manual
الموديل: XH-W3001
Brand: UMLIFE
المنتج انتهىview
The UMLIFE XH-W3001 Digital LED Temperature Controller Module is a versatile thermostat switch designed for precise temperature control in various applications. It features a clear digital display and a waterproof NTC10K probe, making it suitable for both heating and cooling modes. Its robust ABS flame retardant housing ensures safety and durability.

Figure 1: UMLIFE XH-W3001 Digital LED Temperature Controller Module with probe and wiring.
الميزات الرئيسية
- ضوء مؤشر LED: Displays the current output status for easy monitoring.
- أنبوب العرض الرقمي: Shows measuring temperature with high accuracy.
- وضعين للعمل: Supports both heating (start temperature < stop temperature) and cooling (start temperature > stop temperature) operations.
- نطاق واسع لدرجة الحرارة: Operates from -50℃ to 110℃ with a control precision of 0.1℃.
- السكن الدائم: Constructed with ABS flame retardant material for high safety, aging resistance, and durability.
- مسبار مقاوم للماء: Equipped with a 1-meter NTC10K stainless steel probe that is waterproof and rust-resistant.
الإعداد والتوصيل
Proper wiring is crucial for the safe and correct operation of the XH-W3001 module. Ensure all connections are secure before applying power.

Figure 2: Wiring diagram for the 12V XH-W3001 model. Connect the 12V input (red/black wires) to your power source. The output (yellow/black wires) connects to your load (e.g., a light bulb or fan). The sensor probe connects to the designated port.
تعليمات الأسلاك:
- مدخلات الطاقة: Connect the red wire to the positive (+) terminal of your 12V DC power supply and the black wire to the negative (-) terminal.
- تحميل الإخراج: Connect the yellow wire to the positive (+) terminal of your heating or cooling device (load) and the black wire to the negative (-) terminal of the load. Ensure the load's voltage matches the controller's input voltagه (12 فولت).
- مسبار درجة الحرارة: Insert the NTC10K waterproof probe into the designated two-pin connector on the module.

Figure 3: Labeled components of the XH-W3001 module, showing the temperature LED display, indicator light, up button, down button, and model number.
تعليمات التشغيل
The XH-W3001 has two main parameters to set: the start temperature and the stop temperature.
Setting Start Temperature:
- اضغط مع الاستمرار على زر لأعلى (left button) for approximately 3 seconds. The display will start flashing, indicating it's in setting mode.
- استخدم Up و الأزرار السفلية to adjust the desired start temperature.
- اضغط على زر لأعلى again or wait for 3 seconds for the setting to be saved automatically.
Setting Stop Temperature:
- اضغط مع الاستمرار على الزر الأسفل (right button) for approximately 3 seconds. The display will start flashing.
- استخدم Up و الأزرار السفلية to adjust the desired stop temperature.
- اضغط على الزر الأسفل again or wait for 3 seconds for the setting to be saved automatically.
أوضاع التشغيل:
- وضع التدفئة: If the Start Temperature is set أدنى than the Stop Temperature, the module will operate in heating mode. The output will turn ON when the temperature drops below the Start Temperature and turn OFF when it reaches the Stop Temperature.
- وضع التبريد: If the Start Temperature is set أعلى than the Stop Temperature, the module will operate in cooling mode. The output will turn ON when the temperature rises above the Start Temperature and turn OFF when it drops to the Stop Temperature.
Note: The display shows temperature in Celsius only. There is no option to change to Fahrenheit.
صيانة
The XH-W3001 module is designed for low maintenance. Regular checks can ensure its longevity and accurate performance.
- تنظيف: Keep the module and probe clean. Use a soft, dry cloth to wipe the display and housing. For the probe, ensure it is free from debris that might affect temperature readings.
- الاتصالات: افحص جميع توصيلات الأسلاك بشكل دوري للتأكد من أنها محكمة وخالية من التآكل. قد تؤدي التوصيلات غير المحكمة إلى تشغيل متقطع أو تلف الجهاز.
- حالة المسبار: Inspect the temperature probe for any signs of damage to the cable or the sensor tip. Replace if damaged to maintain accuracy.
- بيئة: Ensure the module is installed in an environment within its specified operating temperature and humidity ranges to prevent premature failure.
استكشاف الأخطاء وإصلاحها
If you encounter issues with your XH-W3001 module, refer to the following common problems and solutions:
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| Display not lighting up. | لا يوجد تيار كهربائي، أو توصيلات كهربائية غير صحيحة، أو وحدة معيبة. | Check power supply connections. Ensure correct polarity. Verify power source is active. |
| قراءة درجة الحرارة غير دقيقة. | Damaged probe, probe not properly connected, or environmental interference. | Ensure probe is securely connected. Inspect probe for physical damage. Test with another known accurate thermometer if possible. |
| Output not switching ON/OFF as expected. | Incorrect start/stop temperature settings, load not connected, or faulty relay. | Review and re-set start/stop temperatures. Verify load connections. Ensure the load's power requirements are within the module's specifications (10A 120W for 12V model). |
| Display shows "LLL" or "HHH". | "LLL" indicates open circuit or probe not connected. "HHH" indicates short circuit or temperature exceeding range. | Check probe connection. Replace probe if damaged. Ensure temperature is within -50℃ to 110℃ range. |
تحديد
| ميزة | مواصفة |
|---|---|
| رقم الموديل | XH-W3001 |
| المجلدtage | 12 Volts (for this specific model) |
| تيار الخرج | الحد الأقصى 10 أمبير |
| طاقة الإخراج | Max 120W (for 12V model) |
| نطاق التحكم في درجة الحرارة | -50 درجة مئوية إلى 110 درجة مئوية |
| دقة قياس درجة الحرارة | ±0.2 درجة مئوية |
| دقة التحكم في درجة الحرارة | ±0.1 درجة مئوية |
| نوع المسبار | NTC10K (Waterproof) |
| نوع العرض | شاشة عرض رقمية LED |
| مواد الإسكان | ABS مثبطات اللهب |
| أبعاد المنتج | 3.3 × 1.8 × 1.1 بوصة |
| وزن العنصر | 1.76 أونصة (50 جرامًا) |
الضمان والدعم
For warranty information or technical support regarding your UMLIFE XH-W3001 Digital LED Temperature Controller Module, please refer to the product packaging or contact UMLIFE customer service directly. Contact details are typically provided with your purchase or can be found on the manufacturer's official webموقع.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.