DROK LD25

DROK LD25 USB Load Tester Instruction Manual

الموديل:LD25

1. المقدمة

The DROK LD25 USB Load Tester is an intelligent temperature-controlled electronic load module designed for testing USB and Type-C power sources and cables. It features high power, high current, and high voltage capabilities, along with intelligent control for precise measurements. This device is ideal for verifying charger output capacity, testing cable quality, and performing bulk aging tests.

It provides a constant current discharge task up to 4A, 25V, and 25W, offering a user-friendly interface and robust performance for diverse testing requirements.

2. معلومات هامة حول السلامة

تحذير: This product does not have reverse connection protection. The input polarity cannot be reversed. Reversing the input polarity will cause permanent damage to the product and it cannot be repaired. Always ensure correct polarity before connecting the device.

تأكد من تشغيل المجلدtage, current, and power do not exceed the rated maximums to prevent damage to the device or the power source being tested.

3. ميزات المنتج ومكوناته

DROK LD25 USB Load Tester with key features labeled: 4-digit LED display, intelligent cooling fan, precision adjustable potentiometer, and protection indicators for OVP/OPP/OTP.
الشكل 3.1: الميزات الرئيسيةview
من أعلى إلى أسفل view of the DROK LD25 USB Load Tester with components labeled: Micro USB Port, ON/OFF Key, Smart Temperature Control Fan, Adjustable Potentiometer, USB Male Port, Type-C Port, 4-Digit LED Digital Display, SET Key, and Full Aluminum Heat Sink.
Figure 3.2: Component Identification
  • 4-Digit LED Digital Display: يظهر المجلدtage, current, and power values.
  • مروحة التبريد الذكية: Oil bearing fan with intelligent temperature control, speed up to 5800±10% RPM. Activates automatically when current exceeds 2A or temperature exceeds 40°C.
  • Precision Adjustable Potentiometer: Allows fine-tuning of the output current.
  • USB Male Port: For connecting to USB power sources.
  • Micro USB Port (Max. Current: 2A): For testing Micro USB cables and devices.
  • Type-C Port (Max. Current: 4A): For testing Type-C cables and devices.
  • مفتاح تشغيل / إيقاف: Short press to toggle the load output on or off. Long press to set the default boot state (output on or off) for future use.
  • زر التجهيز او التنصيب: Short press to cycle through the display modes: Voltage (V), Current (A), and Power (W). Long press to enter the protection setting menu.
  • Full Aluminum Heat Sink: Efficient heat dissipation for stable operation.
  • ميزات الحماية: أكثر من المجلدtage protection (OVP), Over-power protection (OPP), Over-temperature protection (OTP).

4. المواصفات

Detailed specifications table for the DROK LD25 USB Load Tester, including operating voltage, discharge power, operating current, fan speed, constant current accuracy, operating temperature, potentiometer type, display type, product interfaces, product weight, and product dimensions.
الشكل 4.1: مواصفات المنتج
المعلمةقيمة
تصنيف حجم التشغيلtageالعاصمة 4-25.0V
أقصى طاقة تفريغ25 واط
تيار التشغيل المقدر0.25-4.00A (Min. 0.05A when fan is off)
سرعة المروحةOil bearing intelligent temperature control fan, 5800±10% RPM
Constant Current Resolution± (1٪ + 3 أرقام)
طريقة تبديد الحرارةIntelligent temperature control fan + Aluminum heat sink
درجة حرارة العمل-10 درجة مئوية ~ +40 درجة مئوية
مقياس الجهد قابل للتعديلPrecision multiloop adjustable potentiometer
وضع العرض4-bit LED tube
موانئ التوسعMicro USB port, Type-C port
أبعاد المنتج84 × 41 × 28 مم
وزن المنتج57 جرام
جانب view of the DROK LD25 USB Load Tester showing its dimensions: 83mm length, 43mm width, and 27mm height.
الشكل 4.2: أبعاد المنتج

5. الإعداد

  1. Prepare Power Source: Ensure the power source (e.g., USB charger, power bank) you intend to test is within the operating voltagنطاق DC 4-25.0V.
  2. Connect the Load Tester:
    • For standard USB power sources: Plug the USB male port of the LD25 directly into the USB output port of your charger or power bank.
    • For Micro USB or Type-C cables/devices: Connect the Micro USB or Type-C port of the LD25 to the respective cable or device.
  3. تحقق من الاتصال: Once connected, the 4-digit LED display should illuminate, indicating the device is powered on. If it does not power on, check the connection and ensure the power source is active.
  4. Initial Current Setting: Before applying a load, ensure the adjustable potentiometer is set to a low current or off position to avoid sudden high current draw.

6. تعليمات التشغيل

6.1 التشغيل الأساسي

  1. تشغيل/إيقاف التشغيل:
    • اضغط لفترة قصيرة على مفتاح تشغيل / إيقاف to toggle the load output on or off.
    • اضغط لفترة طويلة على مفتاح تشغيل / إيقاف to set the default boot state (output on or off) for future use.
  2. ضبط الحالي: تدوير مقياس الجهد قابل للتعديل to increase or decrease the discharge current. The current value will be displayed on the LED screen. Adjust gradually to the desired load.
  3. أوضاع العرض: اضغط لفترة قصيرة على زر التجهيز او التنصيب to cycle through the display modes: Voltage (V), Current (A), and Power (W).
  4. Setting Protection Modes: اضغط لفترة طويلة على زر التجهيز او التنصيب to enter the protection setting menu. Refer to Section 7 for details on protection functions.

6.2 تشغيل مروحة التبريد الذكية

The intelligent cooling fan will automatically activate under the following conditions to maintain optimal operating temperature:

  • When the discharge current exceeds 2A.
  • When the internal temperature of the device exceeds 40°C.

The fan supports continuous 25W discharge and ensures uninterrupted operation by efficiently dissipating heat.

Close-up of the DROK LD25 USB Load Tester highlighting protection features and smart cooling control. Details include OVP, OTP, OPP protection, error code display, burnout prevention, and fan activation conditions.
Figure 6.1: Protection and Cooling Details

7. وظائف الحماية واستكشاف الأخطاء وإصلاحها

The LD25 USB Load Tester incorporates several protection mechanisms to ensure safe operation and prevent damage to the device and connected equipment.

  • OVP (المجلد الزائدtagالحماية الإلكترونية):
    • Activates if the input voltage exceeds 25V (up to 30V).
    • The digital display will show "OVP".
    • حذر: المجلدtages exceeding 30V can cause permanent damage.
  • OTP (حماية من درجة الحرارة الزائدة):
    • Activates if the load temperature exceeds 80°C.
    • The device will stop working, and the digital display will show "OTP".
  • OPP (حماية الطاقة الزائدة):
    • Activates if the discharge power exceeds 25W.
    • The device will stop working, and the digital display will show "OPP".

When a protection condition is met, the device will halt operation. To resume, address the underlying issue (e.g., reduce voltage, allow cooling, reduce power draw) and then manually or automatically reset the load as configured.

8. التطبيقات

The DROK LD25 USB Load Tester is a versatile tool for various testing scenarios:

  • Charger Testing: Measure the actual output current capacity of USB chargers and power banks.
  • Cable Quality Testing: Evaluate the quality and performance of Micro USB and Type-C charging cables by observing voltage drop under load.
  • Bulk Aging Tests: Suitable for factory quality control and aging tests of chargers and power supplies.
  • Power Delivery Verification: Confirm stable power output from various USB power sources.
Examples of DROK LD25 USB Load Tester applications: testing Type-C/Micro USB cables, charger testing, and batch aging testing with multiple units.
Figure 8.1: Wide Application Exampليه

9. الصيانة

To ensure the longevity and accurate performance of your DROK LD25 USB Load Tester:

  • تنظيف: استخدم قطعة قماش ناعمة وجافة لتنظيف الجهاز. لا تستخدم المنظفات السائلة أو المذيبات.
  • تخزين: قم بتخزين الجهاز في مكان بارد وجاف بعيدًا عن أشعة الشمس المباشرة ودرجات الحرارة القصوى.
  • التعامل: تجنب إسقاط الجهاز أو تعريضه لصدمات قوية.
  • تهوية: Ensure the cooling fan and heat sink are free from dust and obstructions to maintain efficient heat dissipation.

الضمان والدعم

For warranty information and technical support, please refer to the documentation provided with your purchase or contact DROK customer service directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.