The GeneralAire Model 3200M Evaporative Humidifier is designed to provide optimal humidity levels for homes up to 3200 square feet. This newly engineered humidifier is optimized for maximum humidity output, especially with today's high-efficiency furnaces that often operate at lower plenum temperatures. Its compact and lightweight design ensures easy installation and straightforward maintenance, making it an efficient solution for maintaining comfortable indoor air quality.

Figure 1: GeneralAire Model 3200M Evaporative Humidifier. This image shows the compact, white humidifier unit designed for duct mounting.
2. الميزات الرئيسية
- Designed for Modern Furnaces: Optimized for today's lower plenum temperatures (95°-120°F) with high-efficiency furnaces, ensuring effective humidity capture.
- تصميم موفر للمساحة: يتميز باحترافية منخفضةfile cover and chassis, allowing for installation in smaller spaces.
- Efficient "Ram" Air Design: Scoop cover design forces hot furnace air directly through the Vapor Pad at its warmest point, maximizing humidity output.
- Optimized Pad Surface: A thinner chassis frame exposes more of the Vapor Pad for maximum humidity output.
- Durable Water Distribution: Equipped with stainless steel water supply tubing, allowing for hot water service and increased Gallons Per Day (GPD).
- Easy Maintenance Access: The UV stable cover is easily removed by lifting bottom tabs and then lifting the top portion off, providing quick access to the Vapor Pad holder.
- التثبيت المرن: The cover, solenoid valve, and water distribution tube can be swiftly reoriented from left to right to accommodate various installation configurations.
- Replaceable Drain Components: Features a replaceable double-walled drain tube and spout that can be removed for cleaning.
- التحكم اليدوي: Includes an MHX3C Manual Humidistat for straightforward humidity level adjustment.

Figure 2: GeneralAire MHX3C Manual Humidistat. This image displays the manual control dial for adjusting humidity levels.
Video 1: General Aire Humidifiers Overviewيقدم هذا الفيديو نظرة عامةview of GeneralAire humidifiers, highlighting key features and benefits of the product line, including the 3200M model.
3. الإعداد والتثبيت
Proper installation is crucial for the efficient operation of your GeneralAire Model 3200M Humidifier. It is highly recommended that installation be performed by a qualified HVAC professional or electrician to ensure safety and correct connections.
3.1. اختيار موقع التركيب
The humidifier should be installed on the warm air supply plenum or return air duct of your furnace system. Ensure there is sufficient space for the unit and for future maintenance access.
3.2. Duct Opening and Mounting
- Using the provided template (if applicable) or the unit's dimensions, mark the area on the ductwork where the humidifier will be mounted.
- Carefully cut the marked opening in the ductwork. Ensure all sharp edges are deburred to prevent injury and damage to components.
- Position the humidifier's chassis into the cut opening and secure it to the ductwork using appropriate fasteners (not included).
3.3. توصيل المياه
- Connect the stainless steel water supply tubing to a cold or hot water line, as preferred. Hot water service can increase GPD output.
- Install a shut-off valve and an inline water filter (if desired) in the water supply line to the humidifier.
- Connect the water supply line to the humidifier's inlet. Ensure all connections are watertight.
3.4. وصلة الصرف
- Connect the humidifier's drain tube to a suitable floor drain or condensate pump.
- Ensure the drain line has a continuous downward slope to allow for proper drainage and prevent standing water.
3.5. Humidistat Installation (MHX3C Manual Humidistat)
- Install the MHX3C Manual Humidistat in a central living area of your home (e.g., bedroom, living room, kitchen) where it can accurately sense the room's humidity. Avoid locations near heat sources, cold drafts, or directly in the path of humidifier output.
- Wire the humidistat to the humidifier and the furnace control board according to the wiring diagram provided in the separate humidistat instructions.
- مهم: The humidifier operates on 24 Volts AC. Connecting it to a 120 Volts AC source will damage the unit. Consult an HVAC professional for electrical connections.
4. تعليمات التشغيل
Once installed, operating your GeneralAire Model 3200M Humidifier is straightforward using the MHX3C Manual Humidistat.
4.1. Setting Desired Humidity Level
- Locate your MHX3C Manual Humidistat.
- Turn the dial on the humidistat to your desired humidity percentage. A common comfortable range is between 35% and 45% relative humidity.
- The humidifier will activate when the furnace blower is running and the sensed humidity level in your home falls below the set point on the humidistat.
- Adjust the dial as needed to maintain comfort levels, especially as outdoor temperatures change. Lower humidity settings are generally recommended during colder outdoor temperatures to prevent condensation on windows.
5. الصيانة
Regular maintenance ensures the longevity and efficient performance of your humidifier. The GeneralAire 3200M is designed for easy maintenance.
5.1. Vapor Pad Replacement
The Vapor Pad should be replaced at least once per heating season, or more frequently depending on water quality and usage.
- Turn off the power to the furnace and humidifier at the circuit breaker.
- Turn off the water supply to the humidifier at the shut-off valve.
- Remove the UV stable cover by gently pulling out the bottom tabs and then lifting the top portion off the top tabs.
- Open the hinged door of the humidifier.
- Carefully slide out the old Vapor Pad assembly.
- Insert a new GeneralAire Vapor Pad into the assembly, ensuring it is correctly oriented.
- Slide the Vapor Pad assembly back into the humidifier.
- Close the hinged door and reattach the UV stable cover, ensuring it snaps securely into place.
- Restore water supply and power to the unit.
5.2. Drain Tube and Spout Cleaning
The replaceable double-walled drain tube and spout can be removed for cleaning to prevent mineral buildup and clogs.
- Turn off the power and water supply to the humidifier.
- Locate the drain tube and spout at the bottom of the humidifier.
- Carefully detach the drain tube and remove the spout.
- Clean any mineral deposits or debris from the drain tube and spout using a brush and mild detergent.
- Rinse thoroughly and reattach the spout and drain tube, ensuring a secure connection.
- Restore water supply and power.
5.3 تنظيف بشكل عام
Periodically wipe down the exterior of the humidifier with a damp قطعة قماش لإبقائها نظيفة.
6. استكشاف الأخطاء وإصلاحها
If your GeneralAire Model 3200M Humidifier is not operating as expected, consult the following troubleshooting guide before contacting customer support.
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| لا يوجد مخرج للرطوبة |
|
|
| تسربات المياه |
|
|
| ضوضاء غير عادية |
|
|
7. المواصفات
- ماركة: جنرال اير
- اسم الموديل: evaporative humidifier
- رقم الموديل: 3200 مليون
- ميزة خاصة: Evaporative, Bypass, Flow Through
- لون: أبيض
- مساحة الأرضية: 3200 قدم مربع
- وضع التشغيل: التبخر
- وزن السلعة: 3.5 رطل
- نوع الغرفة: غرفة المعيشة غرفة نوم
- المكونات المتضمنة: MHX3C Manual Humidistat
- المجلدtage: 24 فولت
- واتtage: 12 واط
- مصدر الطاقة: كهرباء سلكية
- أبعاد المنتج: 8.5 × 12 × 12.25 بوصة
8. الضمان والدعم
For detailed warranty information, product registration, and customer support, please visit the official GeneralAire webالمواقع:
- الولايات المتحدة الأمريكية: www.generalaire.com
- كندا: www.generalaireiaq.ca
من المستحسن الاحتفاظ بإيصال الشراء كإثبات للشراء في حالة المطالبات بالضمان.