This manual provides detailed instructions for the proper use, setup, operation, maintenance, and troubleshooting of the INSIZE ISH-DSA Digital Shore Durometer, Shore A. This precision instrument is designed for measuring the hardness of soft plastics, soft rubber, and similar materials. Adhering to the guidelines in this manual will ensure accurate measurements and prolong the life of your device.

INSIZE ISH-DSA Digital Shore Durometer, Shore A

وصف الصورة: لقطة مقربة view of the INSIZE ISH-DSA Digital Shore Durometer, Shore A. The device features a digital display showing a reading of "64.4" with average and standard deviation values. Below the display is the "INSIZE" logo and a control panel with power, up, down, and OK buttons. The measurement probe extends from the bottom of the device.

2. معلومات السلامة

  • Always handle the durometer with care to prevent damage.
  • تجنب تعريض الجهاز لدرجات حرارة قصوى أو رطوبة عالية أو بيئات أكالة.
  • Do not attempt to disassemble the unit, as this will void the warranty and may cause damage.
  • أبعد الجهاز عن المجالات المغناطيسية القوية.
  • Ensure the test surface is stable and secure to prevent accidents during measurement.

3. مكونات المنتج

The INSIZE ISH-DSA Digital Shore Durometer package typically includes:

  • INSIZE ISH-DSA Digital Shore Durometer
  • حقيبة تخزين واقية
  • دليل المستخدم (هذا المستند)
  • Calibration block (optional accessory, may be sold separately)

4. الإعداد

Follow these steps to prepare your durometer for first use:

  1. فك التعبئة: Carefully remove the durometer from its packaging. Inspect the device for any visible damage that may have occurred during shipping.
  2. تركيب البطارية: Locate the battery compartment (usually on the back or side). Open it and insert the required batteries (e.g., AAA, specific type not provided in product data), ensuring correct polarity as indicated inside the compartment. Close the compartment securely.
  3. تشغيل الطاقة: Press the power button (often marked with a power symbol or 'ON/OFF') on the control panel to turn on the device.
  4. فحص العرض الأولي: The digital display should illuminate and show a reading, typically "0.0" or a previous measurement. If the display does not light up, check the battery installation or replace the batteries.

5. تعليمات التشغيل

The INSIZE ISH-DSA Digital Shore Durometer is specifically designed for measuring Shore A hardness, suitable for soft materials.

5.1. Basic Measurement Procedure

  1. يجهزampعلى: Ensure the test material (soft plastic, soft rubber, etc.) is flat, smooth, and has a minimum thickness of 6mm. The sample should be at a stable temperature, ideally between 20-25°C (68-77°F).
  2. Position Durometer: Hold the durometer firmly and vertically above the test sample. Ensure the presser foot is parallel to the sampلو السطح.
  3. تطبيق الضغط: Slowly and steadily apply pressure to the durometer until the entire presser foot is in full contact with the sample. The indenter should penetrate the material. Avoid sudden impacts or lateral movements.
  4. قراءة القياس: Observe the digital display. The reading will stabilize, indicating the Shore A hardness value. The device has a resolution of 0.1 Ha.
  5. تسجيل البيانات: Note down the measurement. For accurate results, take multiple readings (at least 5) at different points on the sample, ensuring each measurement point is at least 6mm from any other measurement or edge. Calculate the average for a representative value.

5.2. الميزات المتقدمة

  • نطاق القياس: The device accurately measures within a range of 0 to 100 Ha.
  • إيقاف التشغيل التلقائي: To conserve battery life, the durometer features an automatic power-off function after a period of inactivity.
  • الربط اللاسلكي: This model supports wireless connection to a printer for convenient data output. Refer to the printer's manual for specific pairing and operation instructions.
  • Handhold or Test Stand Use: The device can be used handheld for quick checks or mounted on an optional test stand (not included) for more consistent and repeatable measurements, especially when testing softer materials or requiring precise force application.

6. الصيانة

Proper maintenance ensures the longevity and accuracy of your durometer.

  • تنظيف: Wipe the durometer body with a soft, dry, lint-free cloth. Do not use solvents, alcohol, or abrasive cleaners, as these can damage the display or casing.
  • العناية بأداة الضغط: Keep the indenter tip clean and free from debris, dust, or residue from test samples. Avoid touching the tip with bare hands to prevent oil transfer. Use a soft brush or compressed air if necessary.
  • تخزين: Store the durometer in its protective case in a dry, dust-free environment when not in use. Avoid areas with extreme temperature fluctuations or high humidity.
  • استبدال البطارية: Replace batteries promptly when the low battery indicator appears on the display. If the device will not be used for an extended period (e.g., more than one month), remove the batteries to prevent leakage and potential damage.
  • معايرة: Regular calibration by a qualified technician or an accredited laboratory is highly recommended to ensure the continued accuracy of the instrument, especially for critical measurement applications or after significant use.

7. استكشاف الأخطاء وإصلاحها

This section addresses common issues you might encounter with your durometer.

مشكلةالسبب المحتملحل
الجهاز لا يعملالبطاريات الميتة أو المثبتة بشكل غير صحيحCheck battery polarity, replace batteries with fresh ones.
Inconsistent or fluctuating readingsغير لائق sample preparation; inconsistent pressure application; dirty indenter; unstable test surfaceتأكد من sample is flat, smooth, and thick enough; apply steady, vertical pressure; clean indenter tip; use a stable test platform.
Display shows "Err" or abnormal valuesMeasurement out of range; device malfunction; environmental interferencePower off and on again; ensure measurement is within the 0-100 Ha range; move away from strong electromagnetic fields. If issue persists, contact support.
Wireless printer connection failurePrinter not paired; printer out of range; printer battery lowRefer to printer manual for pairing; ensure devices are within range; check printer battery.

8. المواصفات

Key technical specifications for the INSIZE ISH-DSA Digital Shore Durometer:

ميزةالتفاصيل
نموذجISH-DSA
يكتبDigital Shore Durometer, Shore A
مواد الاختبارSoft plastic, soft rubber, etc.
مدى القياس0~100 Ha
دقة0.1 Ha
الامتثال للمعاييرAccording to ISO868, ISO7619, ASTM D 2240
ميزة الطاقةإيقاف التشغيل التلقائي
الاتصالWireless to printer
طريقة الاستخدامHandhold use or work with test stand
أبعاد الحزمة12.83 × 11.42 × 3.78 بوصة
وزن العنصر1 جنيه
الشركة المصنعةفي الحجم
تاريخ أول توفر4 يونيو 2016

9. الضمان والدعم

For detailed warranty information, technical support, and service inquiries, please refer to the official INSIZE website or contact your authorized INSIZE dealer. It is recommended to keep your purchase receipt as proof of purchase for any warranty claims.

For further assistance or to explore other INSIZE products, you may visit the INSIZE brand page on Amazon.

10. التخلص

This product contains electronic components and batteries. Do not dispose of it with general household waste. Please follow local regulations for the proper recycling and disposal of electronic waste and batteries to protect the environment.

© 2023 INSIZE. All rights reserved.

Ask a question about this manual