ديجيتوس DN-93903

DIGITUS DN-93903 Cat 6 LSA Connection Module User Manual

Model: DN-93903 | Brand: DIGITUS

1. انتهى المنتجview

The DIGITUS DN-93903 LSA connection module is designed for connecting or extending twisted pair cables. It provides excellent performance and connection quality for your network infrastructure.

This shielded Cat 6 LSA insulation displacement connector supports transmission characteristics up to 250 MHz and 1GBase-T applications. It is suitable for AWG 22 to AWG 26 solid and stranded conductors.

The module is versatile, suitable for installation in cable ducts, flush-mounted, and surface-mounted applications. It is ideal for extending existing cables or replacing defective cable sections in your network setup.

DIGITUS LSA connection module with color-coded wiring diagram

Image: The DIGITUS LSA connection module showing the internal LSA terminals with color-coded wiring for EIA/TIA 568 A & B standards. An Ethernet cable is connected to a wall outlet, illustrating a typical application.

2. تعليمات الإعداد

Follow these steps to properly install and connect the DIGITUS DN-93903 LSA connection module:

  1. تحضير الكابلات: Strip approximately 2-3 cm of the outer jacket from the installation cables you intend to connect. Ensure the twisted pairs remain intact.
  2. Open Module: Carefully open the LSA connection module to access the LSA insulation displacement terminals.
  3. إنهاء الأسلاك: Refer to the color-coded wiring diagram on the LSA terminals (EIA/TIA 568 A or B standard). Untwist the wire pairs minimally and place each individual wire into the corresponding slot on the LSA terminal.
  4. أسلاك آمنة: Use an LSA punch-down tool (not included) to press each wire firmly into its slot. The tool will simultaneously cut off any excess wire. Ensure a secure connection.
  5. Integrated Strain Relief: Utilize the integrated strain relief mechanism to secure the incoming cables, preventing accidental disconnections or damage.
  6. Close Module: Once all wires are correctly terminated and secured, carefully close the module housing.
  7. التركيب: Mount the module in your desired location (panel, flush-mounted box, or surface-mounted) using appropriate fasteners (not included).

3. تعليمات التشغيل

The DIGITUS DN-93903 LSA connection module is a passive component designed for permanent cable connections. Once installed, it operates without user intervention.

  • وظيفة: The module extends or connects two network installation cables, maintaining the Cat 6 performance standards.
  • الاتصال: Ensure that the connected cables are properly terminated and connected to active network equipment (e.g., switches, routers) for network functionality.
  • أداء: When correctly installed, the module facilitates data transmission up to 1 Gigabit Ethernet (1GBase-T) with a bandwidth of 250 MHz.

4. الصيانة

The DIGITUS DN-93903 LSA connection module requires minimal maintenance due to its robust design.

  • تنظيف: حافظ على الوحدة خالية من الغبار والأوساخ. استخدم قطعة قماش ناعمة وجافة للتنظيف. لا تستخدم المنظفات السائلة أو المذيبات.
  • الظروف البيئية: Ensure the module is installed in a dry indoor environment, away from excessive moisture, heat, or direct sunlight.
  • التفتيشات: Periodically check the cable connections for any signs of wear, damage, or loose wires. Re-terminate if necessary.

5. استكشاف الأخطاء وإصلاحها

If you experience network connectivity issues after installing the LSA connection module, consider the following troubleshooting steps:

  • لا يوجد اتصال بالشبكة:
    • Verify that all wires are correctly terminated according to the EIA/TIA 568 A or B standard. Incorrect wiring is a common cause of connection failure.
    • Ensure that the LSA punch-down tool was used correctly, making firm contact and cutting excess wire.
    • Check the integrity of the connected network cables. Test them individually if possible.
    • Confirm that all active network equipment (router, switch, PC) is powered on and functioning correctly.
  • سرعة الشبكة بطيئة:
    • Ensure that all connections are secure and that no wires are loose or partially disconnected.
    • Verify that the cables used are Cat 6 compliant to match the module's performance.
    • Check for external interference if the module is installed near power cables or other sources of electromagnetic interference. The module is shielded, but proper installation practices are still important.
  • اتصال متقطع:
    • Re-examine the LSA terminations for any wires that may have come loose or were not fully seated.
    • Ensure the module housing is securely closed and the strain relief is properly applied.

6. المواصفات

ميزةوصف
نموذجDN-93903
خصائص النقلالفئة 6
مجالات التطبيقUp to 250 MHz, 1GBase-T
المعاييرISO/IEC 11801 3rd Edition, EN 50173-1, EIA/TIA 568-C, ANSI, UL
نوع التثبيتSuitable for duct, flush-mounted, and surface-mounted installation
تركيب الكابلاتLSA-strips, color-coded according to EIA/TIA 568 A & B
Conductor AcceptanceAWG 22-26 solid and stranded conductors
مواد الإسكانABS UL-94V-0
RJ45 Jack Contact MaterialNickel-plated phosphor bronze, 0.5 µ gold-plated contact
RJ-45 Shielding MaterialNickel-plated bronze
LSA Cutting Clamp مادةKrone LSA+, UL 94V-0, galvanized phosphor bronze
ثنائي الفينيل متعدد الكلورFR4, UL 94V-0
درجة حرارة التشغيلمن -20 درجة مئوية إلى +70 درجة مئوية
مقاومة العزل> 500 موهم
مقاومة التواصل< 20 milliOhm
القوة العازلة1000 VDC (contact/contact), 1500 VDC (contact/ground)
أبعاد المنتج (العمق × العرض × الارتفاع)15 سم عمق × 9 سم عرض × 3 سم ارتفاع
DIGITUS LSA connection module with dimensions shown in inches and centimeters

الصورة: لقطة مقربة view of the DIGITUS LSA connection module, illustrating its compact size with dimensions of 2.6 inches (6 cm) in length.

7. الضمان والدعم

معلومات الضمان

This DIGITUS DN-93903 LSA Connection Module comes with a ضمان قانوني لمدة عامينيرجى الاحتفاظ بإثبات الشراء لأي مطالبات تتعلق بالضمان.

الدعم الفني

For technical assistance, installation queries, or troubleshooting beyond the scope of this manual, please contact DIGITUS customer support. Refer to the official DIGITUS webللحصول على أحدث معلومات الاتصال، يرجى زيارة الموقع الإلكتروني أو الاطلاع على عبوة المنتج.

When contacting support, please have your product model number (DN-93903) and a detailed description of your issue ready.

© 2023 DIGITUS. All rights reserved.

Ask a question about this manual