Watts 007 QT

Watts 007 QT 1/2-inch Double Check Valve Assembly Instruction Manual

1. انتهى المنتجview

The Watts 007 QT 1/2-inch Double Check Valve Assembly is engineered to prevent the backflow of contaminated water into a potable water supply system. This device is suitable for non-health hazard, continuous pressure applications. Its robust bronze body construction ensures durability and ease of maintenance. The assembly provides protection against both backsiphonage and backpressure backflow, safeguarding water quality.

تتضمن الميزات الرئيسية ما يلي:

  • Cast Bronze body construction for durability.
  • Designed to prevent reverse flow of polluted water.
  • Ideal for non-health hazard continuous pressure applications.
  • Protection against backsiphonage and backpressure backflow.
  • Ease of maintenance with a single cover and top entry design.
  • Replaceable seats and seat discs.
  • Modular construction and compact design.
  • Top-mounted ball valve test cocks.
  • انخفاض الضغط المنخفض.
  • No special tools required for servicing.
Watts 007 QT 1/2-inch Double Check Valve Assembly

Image 1.1: Watts 007 QT 1/2-inch Double Check Valve Assembly. This image displays the bronze body construction and overall compact design of the valve assembly.

2. معلومات السلامة

تحذير: Improper installation or maintenance of this device can lead to serious injury or property damage. Always adhere to local plumbing codes and regulations.

  • يوصى بالتركيب الاحترافي: Installation should be performed by a qualified plumber or certified backflow prevention device tester.
  • الرموز المحلية: Always check with local inspection authorities for specific installation requirements and compliance.
  • حدود الضغط: Do not exceed the maximum working pressure of 175 psi (12.06 bar). Exceeding this limit can cause device failure and potential hazards.
  • جودة المياه: This device is for non-health hazard applications. For health hazard applications, a different class of backflow preventer may be required.
  • حماية العين: Always wear appropriate eye protection when installing, maintaining, or testing the device.
  • إيقاف تشغيل النظام: Ensure the water supply is completely shut off and depressurized before beginning any installation or maintenance procedures.

3. الإعداد والتثبيت

The Watts 007 QT Double Check Valve Assembly is designed for horizontal or vertical installation, depending on local codes and specific model requirements. Ensure proper orientation for optimal performance.

3.1 فحوصات ما قبل التثبيت

  • Verify that the product model (007 QT, 1/2-inch) matches your application requirements.
  • Inspect the valve for any signs of shipping damage.
  • Ensure all necessary tools and materials are available, including appropriate pipe fittings and sealing compounds.
  • Confirm compliance with all local plumbing codes and regulations.

3.2 خطوات التثبيت

  1. اغلاق إمداد المياه: Locate the main water shut-off valve and turn off the water supply to the area where the backflow preventer will be installed. Drain the system to relieve pressure.
  2. اختر موقعا: Choose an accessible location for installation that allows for future maintenance and testing. The device should be installed downstream of the main water meter and upstream of any connections that could introduce contaminants.
  3. تجهيز الأنابيب: Cut and prepare the existing piping to accommodate the 1/2-inch inlet and outlet connections of the valve assembly. Ensure pipe ends are clean and free of burrs.
  4. تركيب الصمام: Install the Watts 007 QT assembly into the pipeline, ensuring the flow arrow on the valve body points in the direction of water flow. Use appropriate thread sealant on all connections.
  5. تشديد الاتصالات: Securely tighten all connections to prevent leaks, but do not overtighten, which could damage the bronze body or fittings.
  6. إمدادات المياه المفتوحة: Slowly open the main water shut-off valve to gradually repressurize the system. Check all connections for leaks.
  7. الاختبار الأولي: After installation, the device should be tested by a certified backflow prevention device tester to ensure proper operation and compliance with local regulations.

4. التشغيل

The Watts 007 QT Double Check Valve Assembly operates automatically to prevent backflow. It contains two independently operating check valves that close to prevent reverse flow when a backflow condition occurs.

  • Under normal flow conditions, both check valves are open, allowing water to pass through freely with minimal pressure drop.
  • If the pressure downstream of the device becomes greater than the supply pressure (backpressure), or if the supply pressure drops below atmospheric pressure (backsiphonage), the check valves will close.
  • The design ensures that if one check valve fails, the other provides a secondary barrier against backflow.
  • The top-mounted ball valve test cocks allow for easy testing of the device's functionality by a certified technician.

5. الصيانة

Regular maintenance and testing are crucial to ensure the continued proper function of your Watts 007 QT Double Check Valve Assembly. This device is designed for ease of service.

5.1 Annual Testing

Local regulations typically require annual testing of backflow prevention devices by a certified tester. This ensures the device is operating correctly and providing the required level of protection.

5.2 الخدمة والإصلاح

The modular construction and top-entry design facilitate easy servicing. If testing indicates a malfunction, the internal components can be accessed and replaced without removing the entire assembly from the pipeline.

  • التفكيك: To access internal components, ensure the water supply is off and the system is depressurized. Remove the single cover.
  • استبدال المكون: The seats and seat discs are replaceable. Use genuine Watts replacement parts to ensure compatibility and performance. No special tools are required for servicing, making repairs straightforward.
  • إعادة التجميع: Reassemble the device carefully, ensuring all seals are properly seated and the cover is securely fastened.
  • Post-Service Testing: After any servicing or repair, the device must be retested by a certified backflow prevention device tester to confirm proper operation.

6. استكشاف الأخطاء وإصلاحها

This section provides guidance for common issues. For complex problems or issues related to backflow prevention, always consult a certified professional.

6.1 المشكلات والحلول الشائعة

  • Leakage from Test Cocks:
    • سبب: Test cock not fully closed or damaged O-ring.
    • حل: Ensure test cocks are fully closed. If leakage persists, the O-ring or test cock assembly may need replacement.
  • Constant Drip/Leak from Valve Body:
    • سبب: Damaged or worn check valve seats/discs, or debris lodged in the check valve.
    • حل: Shut off water, depressurize, and inspect the internal check valve components. Clean any debris or replace worn seats/discs.
  • Reduced Water Flow/Pressure:
    • سبب: Debris accumulation within the valve, or a check valve partially closed.
    • حل: Isolate the valve, depressurize, and inspect for debris. If a check valve is stuck, it may require cleaning or replacement of components.
  • Failure During Annual Test:
    • سبب: Internal component failure, debris, or improper installation.
    • حل: A certified backflow tester will diagnose the specific issue. Follow their recommendations for repair or replacement.

If you encounter issues not listed here or are unsure about a repair, contact Watts customer support or a qualified plumbing professional.

7. المواصفات

رقم الموديل007 QT (Part # 0062131)
مقاس1/2 بوصة
مادةBronze, Silicone
النهاية الخارجيةبرونزي
حجم اتصال المدخل0.5 بوصة
نوع اتصال المدخلتجميع صمام الفحص المزدوج
حجم اتصال المخرج0.5 بوصة
نوع توصيل المنفذف ن ب ت
الحد الأقصى لضغط التشغيل175 رطل لكل بوصة مربعة (12.06 بار)
عدد المنافذ2
وزن العنصر3.45 رطل
أبعاد المنتج (الطول × العرض × الارتفاع)1 × 0.39 × 0.39 بوصة
التقى المواصفاتASSE 1015, AWWA C510, CSA B64.5, IAPMO PS31

8. الضمان والدعم

For specific warranty information regarding your Watts 007 QT Double Check Valve Assembly, please refer to the documentation included with your purchase or visit the official Watts website. Warranty terms typically cover manufacturing defects under normal use and service.

8.1 دعم العملاء

If you require technical assistance, have questions about installation, operation, or maintenance, or need to inquire about replacement parts, please contact Watts customer support:

  • مسؤول واتس Webموقع: www.whats.com
  • Refer to the product packaging or the Watts website for current contact numbers and email addresses.

When contacting support, please have your product model number (007 QT) and any relevant purchase information readily available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.